background image

  Precautions for Use  

This instrument and its accessories comply with safety standards IEC 61010-1, IEC 61010-031, 
and IEC 61010-2-032 for voltages of 600V in category IV or 1000V in category III.
Failure to observe the safety instructions may result in electric shock, fire, explosion, and 
destruction of the instrument and of the installations.

•  The operator and/or the responsible authority must carefully read and clearly understand 

the various precautions to be taken in use. Sound knowledge and a keen awareness of 
electrical hazards are essential when using this instrument.

•  If you use this instrument other than as specified, the protection it provides may be 

compromised, thereby endangering you.

•  Do not use the instrument on networks of which the voltage or category exceeds those 

mentioned.

•  Do not use the instrument if it seems to be damaged, incomplete, or poorly closed.
•  Before each use, check the condition of the insulation on the leads, housing, and 

accessories. Any item of which the insulation is deteriorated (even partially) must be set 
aside for repair or scrapping.

•  Use only the leads and accessories supplied. Using leads (or accessories) of a lower 

voltage or category reduces the voltage or category of the combined inst leads 
(or accessories) to that of the leads (or accessories).

•  Use personal protection equipment systematically.
•  Keep your hands away from the terminals of the device.
•  When handling the leads, test probes, and alligator clips, keep your fingers behind the 

physical guard.

•  Use only the AC power adapter and battery pack supplied by the manufacturer. They 

include specific safety features.

•  Some current sensors must not be placed on or removed from bare conductors at 

hazardous voltages: refer to the sensor manual and comply with the handling instructions

www.

ShopAEMC

.ca

Shop for AEMC products online at:

1.800.561.8187

Summary of Contents for PowerPad 8435

Page 1: ...SER GUIDE 8435 PowerPad IMPORTANT WARRANTY NOTE By registering online within 30 days from the date of purchase your warranty will be extended to 3 years www ShopAEMC ca Shop for AEMC products online at 1 800 561 8187 ...

Page 2: ...ic Tool Bag Cat 2133 73 12 Color coded ID Markers Cat 2140 45 Also Included 4 GB USB Stick DataView User Manual 9 6V NiMh Battery installed 2 GB SD Card installed High Voltage Warning Caution Card Kit Cat 2136 42 only also includes 4 AmpFlex Model A196 24 BK 1 5 ft USB Cable Cat 2140 46 1 110V Power Cord Cat 5000 63 5 Black Test Leads and Alligator Clips Cat 2140 73 www ShopAEMC ca Shop for AEMC p...

Page 3: ...ase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer Serial _________________________________ Catalog 2136 41 2136 42 Model 8435 Please fill in the appropriate date as indicated Date Received __________________________________ Da...

Page 4: ...directives and with regulations covering EMC The trash can with a line through it means that in the European Union the product must undergo selective disposal for the recycling of electric and electronic material in compliance with Directive WEEE 2002 96 EC Definition of Measurement Categories CAT CAT IV Measurement category IV corresponds to measurements taken at the source of low voltage install...

Page 5: ...f it seems to be damaged incomplete or poorly closed Before each use check the condition of the insulation on the leads housing and accessories Any item of which the insulation is deteriorated even partially must be set aside for repair or scrapping Use only the leads and accessories supplied Using leads or accessories of a lower voltage or category reduces the voltage or category of the combined ...

Page 6: ...r voltage current and power for each harmonic through the 50th Determines harmonic current produced by non linear loads Analyzes the problems caused by harmonics according to their order heating of neutrals conductors motors etc Waveforms Mode Displays voltage and current waveforms or vector representation Identifies signal distortion signatures Displays of amplitude and phase unbalance for voltag...

Page 7: ...and SD Card slot cover Connection Terminals N D L3 C L2 B L1 A N D L3 C L2 B L1 A E GN 2 1 1 Four 4 current inputs on the top of the instrument to enable the use of current sensors MN SR AmpFlex MiniFlex J93 and MR probes 2 Five 5 voltage inputs Each terminal is protected by a weatherproof plug The plugs must be removed to connect the leads then stored in the pouch inside the front cover Leave the...

Page 8: ...armonics are used or not used in calculations of reactive quantities power and energy With harmonics Harmonics are taken into account when calculating reactive parameters Without harmonics Only the fundamental part is used for the calculation of reactive parameters Electrical Connection Determines the type of connection to the network Single Phase Split Phase 3 Phase 4 Wire 3 Phase 5 Wire Sensors ...

Page 9: ...ensors to the PowerPad Connect the ground and or neutral lead to the network ground and or neutral when distributed as well as the corresponding current sensor Connect the L1 phase lead to the network L1 phase as well as the corresponding current sensor Repeat the procedure for phases L2 L3 and N Disconnecting Proceed in the reverse order to connecting always finishing by disconnecting the ground ...

Page 10: ...fer to the Model 8435 user manual that is supplied on the USB stick Updating Software Firmware To provide our customers the best possible service in terms of performance and technical upgrades AEMC offers free software and firmware updates on our website Visit us at www aemc com Click on the TECH INFO tab then click on the Software Firmware Updates button DataView can also be updated by selecting ...

Page 11: ...repair provided we have your warranty registration on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or e mail from our Service Department then return the instrument along with the signed CSA Form Ple...

Page 12: ...11 14 99 MAN 100390 v2 Chauvin Arnoux Inc d b a AEMC Instruments www ShopAEMC ca Shop for AEMC products online at 1 800 561 8187 ...

Reviews: