ELECTRICAL SPECIFICATIONS
Current Range:
1 A to 100 A AC, continuous
Output Signal:
10 mV AC/A AC
(1 V @ 100 A)
Accuracy and Phase Shift*:
Accuracy:
1 to 100 A: 2% ± 50 mA
40 Hz to 3 kHz: 3.5% ± 50 mA
Phase Shift:
1 to 100 A: ≤ 6° 50 to 60 Hz
(*Reference conditions: 23°C ± 3°K, 20
to 85% RH, 48 to 65 Hz, external
magnetic field < 40 A/m, no DC
component, no external current
carrying conductor, test sample
centered.) Load impedance 1 MΩ.
Overload:
120 A continuous
Frequency Range:
30 Hz to 5 kHz
Load Impedance:
100 KΩ min.
Working Voltage:
600 V AC
Common Mode Voltage:
600 V AC
MECHANICAL SPECIFICATIONS
Operating Temperature:
14° to 122°F (-10° to 50°C)
Storage Temperature:
-40° to 176°F (-40° to 80°C)
Temperature Influence:
< 0.2% per 10°K
Maximum Cable Diameter:
0.47” Ø max. (12 mm)
Dimensions:
1.26 x 4.53 x 0.87"
(32 x 115 x 22 mm)
Weight:
160 g (6 oz)
Colors:
Dark gray handles with red cover
Polycarbonate Material:
Handle: 10% Fiberglass charged
polycarbonate UL 94 V0
Output:
Insulated 5 ft. (1.5 m) lead with safety 4mm
banana plug
SAFETY SPECIFICATIONS
Electrical:
- 600 V max common mode between
output and ground
- 3 kV 50/60 Hz dielectric for 1 mn between
core and output cable
ORDERING INFORMATION
AC Current Probe MN115 .......
Cat #2110.72
Accessories:
Banana plug adapter
(to nonrecessed plug) ............
Cat #1017.45