2

thank you for purchasing our 

spring loaded 10A test probes

. these test probes are designed for use 

with aeMc

®

 Micro-ohmmeters Model 6240 and 6250 or equivalent.

For best results from your instrument:

 

„

read

 these operating instructions carefully,

 

„

comply with

 the precautions for use.

Warning, risk of danger! the operator must refer to these instructions whenever this 
danger symbol appears.

the ce marking indicates conformity with the european lVd and eMc directives.

in the european union, this product is subject to a separate collection system for recycling 
electrical and electronic components in accordance with directive Weee 2002/96/ec

Definition of measurement categories:

 

„

Measurement category iV corresponds to measurements taken at the source of low-voltage installations.
example: power feeders, counters and protection devices.

 

„

Measurement category iii corresponds to measurements on building installations.
example: distribution panel, circuit-breakers, machines or fixed industrial devices.

 

„

Measurement category ii corresponds to measurements taken on circuits directly connected to low-
voltage installations.
example: power supply to electro-domestic devices and portable tools. 

PREcAUtIONS FOR USE

the protection of this accessory can be compromised if it is used in a way that is not recommended by 
the manufacturer.

 

„

observe the maximum voltage, intensity and measurement category. do not use the accessory on networks
where the voltage or category exceeds those stated in this manual.

 

„

observe the conditions of use (e.g. temperature, humidity, altitude, degree of pollution and location of use).

 

„

do not use the accessory if it is open, damaged or incorrectly reassembled.

 

„

any repairs must be carried out by skilled and approved personnel.

ENGLISH

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 6240

Page 1: ...ENGLISH User manual A www com information itm com 1 800 561 8187 ...

Page 2: ... feeders counters and protection devices Measurement category III corresponds to measurements on building installations Example distribution panel circuit breakers machines or fixed industrial devices Measurement category II corresponds to measurements taken on circuits directly connected to low voltage installations Example power supply to electro domestic devices and portable tools Precautions f...

Page 3: ...de in 4 wire mode therefore lead resistance compensation is not necessary The straight spring loaded test probe which is thicker allows a more rugged use The pistol grip test probe is used for applications in more confined spaces NOTE At the other end of the leads there are safety terminals 4mm in diameter onto which spaded lugs 6mm in diameter are screwed into These probes can therefore be used w...

Page 4: ... make contact at the measurement point Red spot that identifies the voltage probe P Screw on spaded lugs for connection to the instrument One with a red sleeve for the voltage and one with a black sleeve for the current Flexible lead Guard Under the housing spare cap www com information itm com 1 800 561 8187 ...

Page 5: ...ies the voltage probe P Guard Under the housing spare cap Flexible lead Screw on spaded lugs for connection to the instrument One with a red sleeve for the voltage and one with a black sleeve for the current Retractable and rotating probes to make the contact at the measurement point www com information itm com 1 800 561 8187 ...

Page 6: ... 1 If the instrument has safety terminals unscrew the spaded lugs to make the connection 2 C 2 P 1 P 1 C Place the voltage probes identified by red spots as close as possible to one another During the measurement hold the test probes firmly in contact with the object being measured For details of the measurement configuration technical specifications and error messages refer to the user manuals of...

Page 7: ...nals diameter of 4 mm Mass approximately 2 x 420 g Resistance approximately 2 x 40 mΩ Straight Kelvin probe with rotation Dimensions L x W x H 207 x 34 x 30 mm Diameter of the probes 3 mm Center to center distance between the probes 8 mm Travel of the probes 10 mm Lead 3 15 m long Spade lugs for diameters from 4 to 6 mm Safety terminals diameter of 4 mm Mass approximately 2 x 400 g Resistance appr...

Page 8: ...oduct registration The warranty does not apply in the following cases Inappropriate use of the equipment or use with incompatible equipment Modifications made to the equipment without the explicit permission of the manufacturer Work done on the device by a person not approved by the manufacturer Adaptation to a particular application not anticipated in the definition of the equipment or not indica...

Reviews: