AEMC instruments 2137.57 Quick Start Manual Download Page 11

Power & Energy Logger Model PEL 105 - Quick Start Guide 

11

Installing DataView

®

NOTE: DO NOT connect the instrument to the computer before 

installing the software and drivers.

1. Insert the DataView

®

 thumb drive into an available USB port (wait for driver to 

be installed).

2. If Autorun is enabled, an AutoPlay window appears on your screen. Click 

“Open folder to view files” to display the DataView folder. If Autorun is not 

enabled or allowed, use Windows Explorer to locate and open the USB drive 

labeled “DataView.” 

3. 

When the DataView folder is open, find the file Setup.exe in the USB drive 

root directory and double-click it to run the installation program. 

4. The DataView

®

 setup screen appears. In the upper left section of the screen, 

choose the language for the setup program UI. Then select DataView in the 

Options list and click Install.

5. 

Click OK at the Confirm Setup screen. The InstallShield Wizard welcome 

screen appears. The InstallShield Wizard leads you through the installation 

process. As you complete these screens, be sure to click Power Energy 

Logger when prompted to select the Control Panels to install.

6. When you have completed all screens, click Finish to leave the InstallShield 

Wizard. Then close the DataView

®

 Setup screen. The DataView folder now 

appears on your computer desktop, within this folder is the PEL Control Panel 

 

 icon.

Connecting to the Computer

Before you can use the PEL Control Panel to communicate with your PEL 105, 

you must establish a connection between the instrument and the computer. 

There are six types of connections available:

 

USB cable connection

 

Bluetooth wireless connection 

 

Wi-Fi direct connection

 

Ethernet point-to-point cable connection

 

Network connection via LAN or Wi-Fi

 

Network connection via IRD server

To begin, ensure that you have installed DataView

®

 with the PEL Control 

Panel. Also ensure that the required communication and connection drivers are 

installed on your computer. These drivers are installed as part of the DataView

®

 

installation process.

Summary of Contents for 2137.57

Page 1: ...Power Energy Logger Model PEL 105 WITH AEMC INSTRUMENTS POWER ENERGY LOGGERS ENGLISH Quick Start Guide ...

Page 2: ...742 2346 This documentation is provided as is without warranty of any kind express implied or otherwise Chauvin Arnoux Inc has made every reasonable effort to ensure that this documentation is accurate but does not warrant the accuracy or completeness of the text graphics or other information contained in this documentation Chauvin Arnoux Inc shall not be liable for any damages special indirect in...

Page 3: ...ns An NIST traceable certificate may be requested at the time of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For recalibration please use our calibration services Refer to our repair and calibration section at www a...

Page 4: ...73 Replacement comes in Qty of 1 12 Color coded ID Markers Cat 2140 45 1 5 ft USB Cable Cat 2140 46 1 USB SD Card Adapter Cat 5000 45 1 Power Adapter 110 240 V w Power Cord Cat 5000 19 Also Includes USB Stick DataView User Manual 9 6 V NiMh Battery installed SD Card installed High Voltage Warning Caution Card PRODUCT PACKAGING 2137 57 ...

Page 5: ...igator Clips Cat 2140 73 Replacement comes in Qty of 1 12 Color coded ID Markers Cat 2140 45 1 5 ft USB Cable Cat 2140 46 1 USB SD Card Adapter Cat 5000 45 1 Power Adapter 110 240 V w Power Cord Cat 5000 19 Also Includes USB Stick DataView User Manual 9 6 V NiMh Battery installed SD Card installed High Voltage Warning Caution Card PRODUCT PACKAGING 2137 59 ...

Page 6: ...ard Ethernet socket RJ45 Main Power Supply Input The UKCA marking certifies that the product is compliant with the requirements that apply in the United Kingdom specifically regarding Low Voltage Safety Electromagnetic Compatibility and the Restriction of Hazardous Substances In the European Union this product is subject to a separate collection system for recycling electrical and electronic compo...

Page 7: ...or and responsible authority must read and understand all precautions needed before using the instrument This instrument requires the user to have knowledge and awareness of electrical hazards Observe the conditions of use including temperature relative humidity altitude pollution degree and location of use Do not use the instrument if it appears damaged incomplete or improperly closed Before each...

Page 8: ... 5 Battery LED Yellow Red ON Steady yellow battery is actively charging Blinking yellow once per second battery is recovering from a full discharge Blinking red twice per second Battery is low and there is no external AC power connected OFF Battery is fully charged 6 Phase Sequence Red ON blinks once per second Phase rotation not as expected OFF Phase rotation order is as expected MODEL PEL 105 16...

Page 9: ...Bluetooth is enabled but not currently transmitting Blinking Bluetooth is enabled and transmitting OFF Bluetooth is disabled 11 Recording Green Blinks twice every 5 seconds when recording Blinks once every 5 seconds when not recording 12 Control Button Starts or stops a data recording session Enables or disables Bluetooth Enables or disables Wi Fi When pressed and held down simultaneously with the...

Page 10: ...e voltage at the terminals If AC wall power is disconnected the instrument runs on phase voltage power if it is available and enabled Battery backup power If neither external AC power nor phase voltage is available the instrument runs on battery power Turning the Instrument ON On AC power or phase voltage power the instrument automatically turns ON when you connect it On battery power you must pre...

Page 11: ...elcome screen appears The InstallShield Wizard leads you through the installation process As you complete these screens be sure to click Power Energy Logger when prompted to select the Control Panels to install 6 When you have completed all screens click Finish to leave the InstallShield Wizard Then close the DataView Setup screen The DataView folder now appears on your computer desktop within thi...

Page 12: ...th enabled When the computer is Bluetooth ready connect the instrument as follows 1 Open the Bluetooth Devices dialog on your computer to pair the instrument with your computer Different operating systems have different steps for opening this dialog so consult your computer s documentation for instructions 2 When the dialog is displayed click Add a Device A dialog box appears listing the locally a...

Page 13: ...ed assistance press the Help button Point to Point Ethernet Cable To connect via point to point Ethernet your computer must be equipped with an available Ethernet port You must also have an Ethernet cable purchased separately 1 Plug one end of the Ethernet cable into the instrument and the other end into the Ethernet port on the computer 2 With the instrument connected open the PEL Control Panel 3...

Page 14: ...plete the Add and Instrument dialog If you need assistance press the Help button Installing the SD Card Data recording sessions are stored in the included 8 GB SD card which also accepts FAT32 SDHC cards up to 32 GB capacity If the SD card is unformatted you will need to format it before use Formatting can be done through a Microsoft Windows command or through the DataView PEL Control Panel To ins...

Page 15: ...s clock or use the Date and Time fields to select another date and time You can click the Set Time Zone field to select a time zone adjustment This defines the number of hours by which the instrument s local time differs from UTC time For example if you set the adjustment to 4 the PEL 105 will display its local time as 4 hours behind UTC e g when local time is 12 00 PM UTC is 4 00 PM NOTE This adj...

Page 16: ...e write protect sliding tab on the card is in the unlock position towards the metal contacts The SD card is formatted Formatting can be performed either through the PEL Control Panel or through a Windows command on your computer If the LED blinks orange the SD card is full Download any data you want to save to your computer then erase the content of the card through the PEL Control Panel When the ...

Page 17: ...be to L3 L2 L1 L3 V1 V2 V3 N I1 I2 I3 L1 L2 L3 3 Phase 3 Wire 3 current probes 3P 3W 3 VE GND test lead to ground V1 test lead to L1 V2 test lead to L2 V3 test lead to L3 I1 probe to L1 I2 probe to L2 I3 probe to L3 L2 L1 L3 V1 V2 V3 N I1 I2 I3 L1 L2 L3 Distribution Systems and Hook ups The following hookup diagrams and connection instructions are for distribution systems supported by the PEL 105 ...

Page 18: ...to L3 I1 probe to L1 I3 probe to L3 3 Phase 3 Wire Open 3 current probes 3P 3WO3 VE GND test lead to ground V1 test lead to L1 V2 test lead to L2 V3 test lead to L3 I1 probe to L1 I2 probe to L2 I3 probe to L3 3 Phase 3 Wire Y 3 current probes 3P 3WY3 VE GND test lead to ground V1 test lead to L1 V2 test lead to L2 V3 test lead to L3 I1 probe to L1 I2 probe to L2 I3 probe to L3 L2 L1 L3 V1 V2 V3 N...

Page 19: ...ead to L1 V2 test lead to L2 I3 probe to L3 3 Phase 4 Wire Y Balanced 3P 4WYb VE GND test lead to ground VN test lead to neutral N V1 test lead to L1 IN probe to neutral I1 probe to L1 3 Phase 4 Wire Y 2 Element 3P 4WY2 VE GND test lead to ground VN test lead to neutral N V1 test lead to L1 V3 test lead to L3 IN probe to neutral I1 probe to L1 I2 probe to L2 I3 probe to L3 L2 L3 L1 N V1 V2 V3 N I1...

Page 20: ...L3 IN probe to neutral I1 probe to L1 I2 probe to L2 I3 probe to L3 L1 L2 L3 N V1 V2 V3 N I1 I2 I3 N L2 L1 L3 L1 L2 L3 N V1 V2 V3 N I1 I2 I3 N L2 L1 L3 DC 2 Wire dC 2W VE GND test lead to ground VN test lead to the common conductor V1 test lead to conductor 1 IN probe to the common conductor I1 probe to conductor 1 DC 3 Wire dC 3W VE GND test lead to ground VN test lead to the common conductor V1 ...

Page 21: ...GND test lead to ground VN test lead to the common conductor V1 test lead to conductor 1 V2 test lead to conductor 2 V3 test lead to conductor 3 IN probe to the common conductor I1 probe to conductor 1 I2 probe to conductor 2 I3 probe to conductor 3 1 2 3 V1 V2 V3 N I1 I2 I3 ...

Page 22: ...the CSA on the outside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N I S T includes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 E...

Page 23: ...ruments will repair or replace the faulty material at our discretion REGISTER ONLINE AT www aemc com warranty html Warranty Repairs What you must do to return an Instrument for Warranty Repair First send an email to repair aemc com requesting a Customer Service Authorization Number CSA from our Service Department You will be provided a CSA Form and other required paperwork along with the next step...

Page 24: ...MC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 800 343 1391 Fax 603 742 2346 www aemc com 2016 Chauvin Arnoux Inc d b a AEMC Instruments All Rights Reserved 06 23 99 MAN 100428 v09 ...

Reviews: