AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
April 15, 2012 Rev: 5.00
Page 2-1
ENG-FORM: 805-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Section 2.0 Installation
2.1
Introduction
Information in this section consists of unpacking and inspection procedures, installation procedures, post-
installation checks, and installation drawings.
2.2 Unpacking
and
Inspection
Unpack the equipment carefully. Inspect the unit visually for damage due to shipping and report all such
claims immediately to the carrier involved. Note that each unit should have the following:
-
AA36-ECF
Tie
Line
Adapter
-
Product
Information
Card
-
Release
certification
Verify that all items are present before proceeding and report any shortage immediately to your supplier.
2.2.1 Warranty
All Anodyne Electronics Manufacturing Corp. (AEM) products are warranted for 2 years. See the website
www.aem-corp.com/warranty for complete details.
2.3 Installation
Procedures
2.3.1 Warnings
Do not bundle any lines from this unit with transmitter coax lines. Do not bundle any audio or DC power
lines from this unit with 400 Hz synchro wiring or AC power lines. Do not position this unit or wiring from
this unit next to any device with a strong alternating magnetic field such as an inverter, or significant audio
interference will result.
2.3.2 Cautions
In all installations, use shielded cable exactly as shown and ground as indicated. Significant ground
loop and noise problems may result from not following these guidelines.
Use caution when routing ICS tie line wiring as they use low level signals and are prone to coupling
from other sources.
Do not take a ground from the front panel or similar location that shares a ground return with a turn and
bank, horizon or other motor driven instrument. This may cause the unit to pick up the sound of the motor
as ground loop interference.