2.3.7
PAX Mute Function
The AA36-ECF can be equipped with an external switch to mute all ICS signals if desired.
If the AA36-ECF is configured with the PAX Mute Function switch, verify its operation by ensuring that
there is no ICS audio in or out of the AA36-ECF when the switch is enabled.
2.3.8 Post-Installation
Checks
2.3.8.1 Voltage/Resistance
Checks
Do not attach the AA36-ECF until the following conditions are met.
Check the following:
a)
P101 pin
<1>
for +28 Vdc relative to ground.
b) P101
pin
<14>
for continuity to ground (less than 0.5
:
).
c) P101
pin
<4>
for continuity to ground (less than 0.5
:
) when the external PAX Mute switch is
closed (see section 2.3.7 above).
Upon satisfactory completion of all performance checks, make the required log entries and
complete the necessary Regulatory Agency paperwork before releasing the aircraft for service.
2.4 Continued
Airworthiness
Maintenance of the AA36-ECF i
s ‘on condition’ only. Periodic maintenance of this product is not required.
2.5
Accessories Required But Not Supplied
Installation kit p/n AA36-IKC (crimp) is required to complete the installation. Each kit consists of the
following:
AA36-IKC
25-pin D-min Female Crimp Kit (AEM Part No.
D25SL-IKC
)
Quantity Description
AEM
Part
#
1 D-min
25
Socket
Housing 20-21-025
25
MS Crimp Socket
20-26-901
1*
Jack Screw Set
20-27-002
1*
Lock Clip Set
20-27-004
1
25 Pin Connector Hood
20-29-026
* Use as required.