LSC22-001
Environmental Qualification Form
Rev: 1.00
Jan 25, 2017
Page 3 of 4
ENG-FORM: 521-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Conditions
Section
Description of Conducted Tests
Voltage Spike
17.0
Equipment tested to Category A
600 Vpp for 10 μs
Positive and negative spikes
Audio Frequency Conducted
Susceptibility
18.0
Equipment tested to Category B
1.6 Vpp 0.2 to 1 kHz
4.0 Vpp 1 to 15 kHz
Induced Signal Susceptibility
Magnetic Fields Into Equipment
Electric Fields Into Equipment
Magnetic Fields Into Cables
Electric Fields Into Cables
Spikes Induced Into Cables
19.0
19.3.1
19.3.2
19.3.3
19.3.4
19.3.5
Equipment tested to Category ACE
20 Arms @ 400 Hz
170 Vrms @ 400 Hz
18 A•m @ 380 to 420 Hz
360
V•m from 380 to 420 Hz
Positive and negative spikes as per DO-160G
Radio Frequency Susceptibility
20.0
Category X, no test performed.
Radio Frequency Emission
Conducted RF Emission
Radiated RF Emission
21.0
21.4
21.5
Equipment tested to Category M
Power lines: 150 kHz to 152 MHz
Interconnecting Cables: 150 kHz to 152 MHz
Category X, no test performed.
Lightning Induced Transient
Susceptibility
22.0
Category X, no test performed.
Lightning Direct Effects
23.0
Category X, no test performed.
Icing
24.0
Category X, no test performed.
Electrostatic Discharge
25.0
Equipment tested to Category A
15,000 Vp, 10 positive and negative spikes.
Fire, Flammability
26.0
Compliant to FAR 23.853 by analysis.
(LSC22-001-652-0)