LSC22-001
Environmental Qualification Form
Rev: 1.00
Jan 25, 2017
Page 2 of 4
ENG-FORM: 521-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Conditions
Section
Description of Conducted Tests
Vibration
8.0
Equipment tested to Category S
Profiles B and M.
Equipment tested to Category U2
Profiles F and F1.
Explosive Atmosphere
9.0
Category X, no test performed.
Waterproofness
10.0
Category X, no test performed.
Fluids Susceptibility
11.0
Category X, no test performed.
Sand and Dust
12.0
Category X, no test performed.
Fungus
13.0
Category X, no test performed.
Salt Fog
14.0
Category X, no test performed.
Magnetic Effect
15.0
Equipment tested to Category Z
Defection of 1°: 0 ≤ D ≤ 0.3
m
Power Input
Voltage (Average Value DC)
Momentary Power Interruptions (DC)
Normal Surge Voltage (DC)
Engine Starting Undervoltage (DC)
Voltage Steady State (DC)
Low Voltage Conditions (DC)
Momentary Undervoltage Operation (DC)
Abnormal Surge Voltage (DC)
16.0
16.6.1.1
16.6.1.3
16.6.1.4
16.6.1.5
16.6.2.1
16.6.2.2
16.6.2.3
16.6.2.4
Equipment tested to Categories BXX
Maximum Operating Voltage: +30.3 Vdc
Nominal Operating Voltage: +28.0 Vdc
Minimum Operating Voltage: +22.0 Vdc
Emergency Operating Voltage: +18.0 Vdc
50ms Max
As per DO-160G
As per DO-160G
Maximum Operating Voltage: +32.2 Vdc
Nominal Operating Voltage: +28.0 Vdc
Minimum Operating Voltage: +20.5 Vdc
As per DO-160G
+12 Vdc for 7 s
+60 Vdc for 100ms, +40 Vdc for 1 s