AEM EV
VCU200 User Guide
Revision C
Page 1: ...AEM Performance Electronics 2205 W 126 th Street Unit A Hawthorne CA 90250 Phone 8am 5pm M F PST 310 484 2322 Fax 310 484 0152 sales aemev com tech aemev com AEM EV VCU200 User Guide Revision C...
Page 2: ...ou should refer the installation and calibration to a reputable installation facility or contact AEM EV for a referral in your area When access is required near the battery pack the cell segments must...
Page 3: ...MAGES OF ANY AMOUNT OR CHARACTER INCLUDING WITHOUT LIMITATION ANY GENERAL INDIRECT SPECIAL INCIDENTAL EXEMPLARY CONSEQUENTIAL OR PUNITIVE DAMAGES ARISING OUT OF RELATED TO OR IN CONNECTION WITH 1 YOUR...
Page 4: ...ility and other compatible 3rd party displays and data loggers About this document This document is not a comprehensive step by step guide to every feature available It is intended to get the VCU powe...
Page 5: ...ly match the Version in the example image below Run the executable to install the hardware drivers It is always a good idea to restart your PC after installing new hardware drivers Please do so Harnes...
Page 6: ...FactoryBase calibration which should be in the Documents AEM AEMcal Calibrations Factory folder 3 Load the Default200 layout file which should be in the Documents AEM AEMcal Layouts Factory folder 4...
Page 7: ...ection list If your device drivers were installed correctly your adapter should appear in this list The example shows the Kvaser Leaf Light v2 If it does not appear try restarting AEMCal If you still...
Page 8: ...and repeating the process If you got this far congratulations Your VCU is powered up and communicating with AEMCal Basic VCU Function Check AEMCal Work Space Tour 1 Within AEMCal navigate to the Setu...
Page 9: ...uration Options There are several fundamental configuration settings required 1 Go to the Setup ConfigOptions group and select the Configuration tab 2 Select each setting and read the Description fiel...
Page 10: ...your application Accelerator Pedal Select the AccelPedal tab This tab is large but for most applications there are only a handful of settings changes required The basic pedal calibration process is a...
Page 11: ...the Brake Switch input to your VCU 3 Read the notes and Descriptions and configure for your application Drive Mode PRND Inputs Discrete PRND switch inputs are required for indirect drive applications...
Page 12: ...ation faults can cause electric shock personal injury and even death An insulation monitoring device IMD must be used to protect against these faults See Bender https www benderinc com for more inform...
Page 13: ...hannels These output functions are not re assignable 3 Manual override settings are available for testing each output Set the _OvrVal to 1 then set the _OvrSts to override to override the the output l...
Page 14: ...channel 3 Configure the settings for your application The ContactorPreConditions channel list is helpful information for first time setups Read the Description for each channel and monitor during Inv...
Page 15: ...nd a shipping service with package tracking capability Once your package is received by our warranty and repairs department you will be notified and provided with updates PROCEDURES FOR ISSUANCE OF A...