The On Time, Off Time and Min On Time can be used to affect how the warning is displayed when only one
warning is active and are scaled in milliseconds. For example, to have a single message flash at 2Hz, set the
On Time to 1000 and the Off Time to 1000. Setting the Off Time to 0 disables flashing.
The Min On Time can be used to ensure a warning is visible even if it is only briefly triggered. For example, a
low oil pressure alarm triggered during cornering may only occur for a fraction of a second but by setting the
Min On Time to 2000 ensures that the message is displayed for 2 seconds and so is more likely to be seen.
Odometer and Turn Blinkers
AEM CD-7 / CD-7L has a built in odometer function. This is an internal counter backed up to non-volatile
memory that cannot be reset (it is set to zero when the unit is built).
To set up the odometer, choose
Setup | Odometer
. Select an output that is road speed km per second. AEM
DashDesign will automatically create an output called
ODOMETER
which is scaled in km and can be
displayed on the screen.
All AEM base setups include an odometer scaled in both miles and kilometers.
An optional turn blinkers feature is available on some AEM supplied setups. Pins 11 and 12 can be used for
LEFT TURN and RIGHT TURN blinkers respectively. When these inputs are grounded, the turn blinkers will
activate.