Test Phone Trouble Shooting 

1.If there is any crosstalk in use, generally it is interference from 

the  telecom line so reduce the volume to reduce the 
interference. Alternately, it can be a poor connection to the line 
under test so check your connections. 

2.If any abnormal situation is found while you are using the 

CZ20252  please  follow your safety procedures before 
proceeding. If safe, test  an alternate  telecommunications  line 
to identify the possible  fault,  referring to the trouble shooting 
list below.   

3.If the CZ20252  still doesn't work after  basic troubleshooting, 

please  return the unit to an authorized service centre  for 
investigation.   

 

Defect Situation 

Possible Problem 

Solution 

Dead, Doesn’t work 

Blown fuse 

Replace fuse 

No tone 

Connection to 
telecommunications line is 
poor 

Check connections to 
telecommunications line 

Speakerphone 
doesn’t work 

MUTE  function is on. 
Check MUTE LED 
indicator 

Press the MUTE button 
and check if the MUTE 
LED is off 

Short rings only 

1.  Low battery 
2.  The test phone is 

intermittently connected 
to a telecommunication 
line. 

1.  Change new battery 
2.  Confirm the test 

telephone is 
adequately connected 
to the right telecom line 

Cannot hear the 
conversations in 
Monitor mode 

1.  The switch is  not set to 

“M” position 

2.  The SPKR button is off 
3.  Low battery 

1.  Set the switch to “M” 

position 

2.  Press the VOL+ button 

to increase volume 

3.  Change a new battery 

Crosstalk 

1.  Connection to 

telecommunications 
line is poor 

2.  Interference from the 

telecom line 

1.  Check connections to 

telecommunications 
line 

2.  Reduce the volume  to 

reduce the interference 

Stored 
numbers/Memory 
doesn’t work 

Low battery 

Change new battery 

Polarity LED  
doesn’t work 

Low battery 

Change new battery 

CABLE LED   
doesn’t work 

Low battery 

Change new battery 

LO HI(LED)   
doesn’t work 

Low battery 

Change new battery 

BATT(LED)   
doesn’t work 

Low battery 

Change new battery 

Summary of Contents for CZ20252

Page 1: ...CZ20252 User Guide CZ20252 ART01 01 IP54...

Page 2: ...r will cause the risk of electric shock or product damage You must ensure the telecommunication line the CZ20252 is being connected to is suitable and free from hazardous voltages before using the CZ2...

Page 3: ...y testing Features 1 IEC EN 60529 IP54 2 Rugged construction for drop and knock proofing 3 Speakerphone for convenient two way hands free conversation 4 High impedance monitor mode DSL safe 5 Direct d...

Page 4: ...2 Keypad 3 Talk Monitor VDC switch 4 Battery Compartment 9V battery 5 Fuse in battery compartment 6 Speakerphone Monitor amplified speaker 7 Line cord strain relief 8 Optional Belt Hook location 2 pla...

Page 5: ...sts the voltage of the line 5 CABLE LED Tests the telecommunication line s continuity On a well connected line the CABLE LED illuminates red 6 Vdc LEDs Voltage line level indicators 7 PSE Button PBX p...

Page 6: ...nfirmed to be safe for a test connection always use Monitor mode to listen for any active services before switching to Talk mode to prevent disconnecting an active service Operating the CZ20252 in Vdc...

Page 7: ...nication line does not have a good continuity Operating in Monitor Mode The M monitor position provides a high impedance coupling to allow line monitoring without disrupting conversations or signallin...

Page 8: ...utton again will switch back to tone dialling Speed Dialling Numbers Storing The STO button is used to store numbers in memory There are 12 memory locations keys 0 through 9 and with each capable of s...

Page 9: ...ssary to insert a pause between digits of a stored number such as when accessing a trunk through a PABX that requires a 9 to get an external line To store a number with a pause simply press the PSE bu...

Page 10: ...ition when storing Ensure the Mute LED is not illuminated when storing as the battery will be drained by the LED Ensure the Mute button is off before storing the CZ20252 to avoid unnecessary battery d...

Page 11: ...elecommunications line Speakerphone doesn t work MUTE function is on Check MUTE LED indicator Press the MUTE button and check if the MUTE LED is off Short rings only 1 Low battery 2 The test phone is...

Page 12: ...on a flat work surface with the battery cover up 2 Use a screwdriver to remove the four screws from the battery compartment 3 Remove the battery cover 4 Remove the old battery and properly discard 5 I...

Page 13: ...same specification 5xL20mm 250mA 250V of fuse 6 Place the battery and battery cover back then fasten the four screws securely Maintenance 1 Disconnect clips from any metallic connections before perfo...

Page 14: ...Digit capacity 16 digits per memory PBX pause duration 4 seconds Line Voltage Test AC DC voltage indication under24 V 24 100V 101 150V 151 200V 200V Monitor amplifier power source 9V providing 25 hour...

Page 15: ...AEGIS CZ20252 User Guide 14 www aegis net au...

Page 16: ...AEGIS CZ20252 User Guide www aegis net au 15 Aegis Proprietary Limited www aegis net au sales aegis net au...

Reviews: