background image

INTRODUCTION  

Thank you for purchasing an Aegis Battery product. It is advised to read and familiarize with the 
contents of this manual prior to use as failure to do so may result in degraded battery characteristics.  
 
The model you have purchased is the 

ABL-012015P 12V, 15Ah

 rated Li-ion NMC Battery featuring 

enhanced  safety,  non-toxicity,  higher  performance  and  extended  service  life  as  compared  with 
traditional  lead-type  batteries  including  but  not  limited  to  SLA,  AGL  and  GEL.  This  battery  was 
assembled in our ISO 9001 Certified production facilities and as such you can expect performance 
and consistency from this product and every other product you may be using or have used.   
 

CONTENTS 

+ Aegis Energies (dba: Aegis Battery) Li-ion NMC Battery Pack 
+ Model Compatible Charger (If optional Charger was purchased)  
+ 1 Copy User Manual  
 
 
 
 
 
 
 
 
 
 
 
 
 

SPECIFICATIONS*   

 

 

Battery Type 

PVC Pack 

Voltage (V) 

12V 

Capacity (Ah) 

180Ah 

Energy Stored (Wh) 

180 Watt-Hours 

Weight 

2.31 lbs. (1.05 kg) 

Dimension (L x W x H) 

120 mm x 70 mm x 70 mm 
4.7 in. x 2.8 in. x 2.8 in. 

Normal Charge Voltage 

29.4V 

Normal Charge Current 

3.0 Amps 

Normal Battery Cutoff Voltage 

19.6V  

Nominal Continuous Discharge Current 

7.5 Amps 

Maximum Continuous Discharge Current 

15.0 Amps 

Maximum Peak Pulse Discharge Current 

30.0 Amps (

5 Seconds

)  

Charge Temperature 

0°C to 45°C 

Discharge Temperature 

-20°C to 60°C 

Operating/Storage Humidity 

60±25%R.H 

Automatic Battery Protection 
Module/System 

Low Voltage Disconnect   
Over Voltage Disconnect 
Short Circuit Protection 
Reverse Polarity Protection 
Cell Balancing 

(

*

For full specifications, please visi

www.aegisbattery.com

 

CHARGING  

PRIOR  TO  INITIAL  USE,  ENSURE  BATTERY  HAS  TAKEN  FULL  CHARGE  AND  IS  IN  A  FULLY 
CHARGED STATE. OUR BATTERIES MAY NOT BE SHIPPED FULLY CHARGED! 

 

MAKE SURE THE CHARGER’S INDICATOR LIGHT HAS  TURNED 

GREEN 

AND WAIT  FOR 30 

MIN. ELAPSE BEFORE UNPLUGGING, CHARGE TIME VARIES FROM MODEL TO MODEL! 

 
When charging your battery, please follow the provided sequence below: 
1.

 

Attach Battery Charging Connector to Charger (This will vary depending on your selected 
model and configuration of battery) 

2.

 

Attach Charger to 110VAC Outlet 

3.

 

When Charging you should observe a 

RED

 LED Indicator: this indicates that the battery is 

currently in the Constant Current (CC) charging phase 

4.

 

Wait for a 

GREEN

 LED Indicator: this indicates the battery is currently in the Constant Voltage 

(CV) charging phase 

5.

 

Wait 30 MINUTES before unplugging the Charger from the 110VAC Outlet 

FIRST

 and then 

disconnecting the Battery from the Charger 

SECOND

 

 

DISCHARGING (STANDARD, SERIES/PARALLEL <0.5C DISCHARGE) 

1.

 

Make sure your load accepts 

12V

 nominal voltage. 

2.

 

Ensure the connection between the battery and the load can handle the current draw. Please 
consult references for the appropriate wire type. 

3.

 

The  maximum  continuous  discharge  current  is 

15A

.  Please  make  sure  your  electrical  load 

consumes a current 

less than 15A continuous and 180 watts of power.

 

4.

 

The battery outputs steady voltage until little capacity remains, do NOT rely on voltage as an 
indicator of remaining capacity, Aegis Battery recommends the usage of an In-Line Watt Meter 
for conveyance of accurate battery discharge telemetry.  

Series: 

Each battery must be charged separately and given a full charge before connecting in series. 

Parallel:

 

Only connect batteries with equal state of charge in parallel. Also, measure the internal 

resistance of each battery and only use batteries with closely matched internal resistance of the 
same make, model and batch origin. It is highly recommended that resistors be used to achieve 
equal internal resistance between batteries and to add fuse(s) to the circuit for safety reasons.  
 

SAFETY GUIDELINES  

Please adhere to the following Safety Guidelines in addition to all disclosed information when using 
your battery. Any damage incurred as a result of a failure to adhere to the recommended usage 
guidelines as collectively disclosed may result in a partial or complete voiding of the warranty as 
provided upon purchase of this battery product. 

Additional Safety Guidelines are as follows.

    

1.

 

Do not disassemble and/or attempt self-repair   

2.

 

Do not short circuit positive and negative terminals 

3.

 

Do not use lead acid chargers as they will cause damage to internal hardware 

4.

 

Do not dispose in normal refuse bin, recycle this product only at designated facilities 

5.

 

For long term storage, fully charge the battery and then discharge to 50% of the full capacity 

6.

 

Do not leave the battery unattended for more than 6 months or in the presence of children 

7.

 

Do not use the battery in or expose the battery to extreme temperatures 

 

 

  

 

 

 

 

Reviews: