PROBLEM
CAUSE
SOLUTION
The pouch is not
sealed correctly
The sealing time is not
correct.
The cover gasket is dirty
or worn.
The pouch is not placed
correctly on the sealing
bar.
The sealing bar is worn
(the Teflon coating is
burnt).
The blade placed under
the Teflon of the sealing
bar is broken.
Change the sealing time.
Clean or replace the cover
gasket (contact the Technical
Assistance Service for a
replacement).
Position the pouch correctly.
Replace the sealing bar (contact
the Technical Assistance Service
for a replacement).
Replace the blade (contact the
Technical Assistance Service for
a replacement).
Final vacuum is
poor
The set vacuum
percentage is incorrect.
The cover gasket is dirty
or worn.
The cover is not closed
correctly.
Change the vacuum percentage.
Clean or replace the cover
gasket (contact the Technical
Assistance Service for a
replacement).
Close the cover correctly.
Make sure that objects or dirt are
not found between the cover and
tank.
The cover does
not open
No power supply.
Wait until the power supply is
restored.
If the machine does not work properly after
the above-mentioned checks, contact the
assistance service describing the detected
defect.
Alarm messages
The appliance detects some alarms, which
are displayed (11) with the following
messages:
OIL:
Replace the pump oil.
Contact the technical assistance service.
OFF:
The electronic board is blocked.
Contact the technical assistance service.
EAA:
The appliance has not reached the
vacuum within the maximum set time (160
seconds).
Make sure the cover is closed correctly.
The cover has not been closed during the
P7 program “Conditioning Program”.
Switch the appliance off and on to reset
the alarm.
FLA:
Power supply voltage is low.
Contact the technical assistance service.