![AEG KS7100000 User Manual Download Page 38](http://html.mh-extra.com/html/aeg/ks7100000/ks7100000_user-manual_2859779038.webp)
ELECTRICAL CONNECTION
WARNING!
Refer to "Safety information" chapter.
The oven is designed to be connected to 230-240V~(50Hz) electricity supply.
The oven has an easily accessible terminal block which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to the electrical supply must comply to the specifica
-
tions given below.
For UK use only
Connection via
Min. size Cable/flex
Cable/flex type
Fuse
Cooker Control Circuit
2,5 mm²
PVC/PVC twin and
earth
min: 15 A
max: 20 A
It is necessary that you install a double pole switch between the oven and the electricity
supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type
suitable for the required load in compliance with the current regulations.
The switch must not break the yellow and green earth cable at any point.
After installation and connecting, the cable must be placed so that it cannot at any point
reach a temperature of more than 50°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic installation can
support the load; and that the power supply is properly earthed.
The manufacturer declines any responsibility should these safety measures not be car-
ried out.
INSTALLATION
WARNING!
Refer to "Safety information" chapter.
The built-in unit must meet the stability requirements of DIN 68930.