background image

9.3 

Other technical data

TOTAL POWER:

Gas original:

G20 (2H) 20 mbar = 3,5 kW

Gas replacement:

G30/G31 (3B/P) 30/30 mbar = 251 g/h

Electric supply:

220-240 V ~ 50/60 Hz

Appliance category:

II2H3B/P

 

Gas connection:

R 1/2"

 

Appliance class:

3

 

9.4 

Gas burners for NATURAL GAS G20 20 mbar

BURNER

NORMAL POWER kW MINIMUM POWER

kW

INJECTOR MARK

Rapid

2,4

0,75

108X

Auxiliary

1,0

0,45

70

9.5 

Gas burners for LPG G30/G31 30/30 mbar

BURNER

NORMAL
POWER kW

MINIMUM
POWER kW

INJECTOR
MARK

NOMINAL GAS
FLOW g/h

Rapid

2,45

0,95

79

178

Auxiliary

1,0

0,45

50

73

10. 

ENVIRONMENTAL CONCERNS

Recycle materials with the symbol 

.

Put the packaging in relevant containers

to recycle it. Help protect the

environment and human health by

recycling waste of electrical and

electronic appliances. Do not dispose of

appliances marked with the symbol 

with the household waste. Return the

product to your local recycling facility or

contact your municipal office.

*

ENGLISH

17

Summary of Contents for HC412001GB

Page 1: ...USER MANUAL EN User Manual Hob HC412001GB ...

Page 2: ... your product for better service www registeraeg com Buy Accessories Consumables and Original spare parts for your appliance www aeg com shop CUSTOMER CARE AND SERVICE Always use original spare parts When contacting our Authorised Service Centre ensure that you have the following data available Model PNC Serial Number The information can be found on the rating plate Warning Caution Safety informat...

Page 3: ...ose of it appropriately Keep children and pets away from the appliance when it operates or when it cools down Accessible parts are hot If the appliance has a child safety device it should be activated Children shall not carry out cleaning and user maintenance of the appliance without supervision 1 2 General Safety WARNING The appliance and its accessible parts become hot during use Care should be ...

Page 4: ...se the appliance If the supply cord is damaged it must be replaced by the manufacturer an authorized Service or similarly qualified persons in order to avoid a hazard Where the appliance is directly connected to the power supply an all pole isolating switch with a contact gap is required Complete disconnection in compliance with the conditions specified in overvoltage category III must be guarante...

Page 5: ...ce is disconnected from the power supply Make sure that the parameters on the rating plate are compatible with the electrical ratings of the mains power supply Make sure the appliance is installed correctly Loose and incorrect electricity mains cable or plug if applicable can make the terminal become too hot Use the correct electricity mains cable Do not let the electricity mains cable tangle Make...

Page 6: ...ce food into hot oil it may splash WARNING Risk of fire and explosion Fats and oil when heated can release flammable vapours Keep flames or heated objects away from fats and oils when you cook with them The vapours that very hot oil releases can cause spontaneous combustion Used oil that can contain food remnants can cause fire at a lower temperature than oil used for the first time Do not put fla...

Page 7: ...aintenance Do not use water spray and steam to clean the appliance Clean the appliance with a moist soft cloth Only use neutral detergents Do not use any abrasive products abrasive cleaning pads solvents or metal objects Do not clean the burners in the dishwasher 2 6 Service To repair the appliance contact an Authorised Service Centre Use original spare parts only 2 7 Disposal WARNING Risk of inju...

Page 8: ... is not hardened but shows its correct elasticity the fastening clamps are not rusted expired term is not due If one or more defects are visible do not repair the pipe but replace it WARNING When installation is complete make sure that the seal of each pipe fitting is correct Use a soapy solution not a flame 3 3 Injectors replacement WARNING The injector kit for gas replacement is not provided Ple...

Page 9: ...cess to the mains plug after the installation Do not pull the mains cable to disconnect the appliance Always pull the mains plug There is a risk of fire when the appliance is in connection with an extension cable an adapter or a multiple connection Make sure that the ground connection agrees with the standards and regulations Do not let the power cable to heat up to a temperature higher than 90 C ...

Page 10: ... mm Depth 490 mm Width sum of all widths of hobs that you install minus 20 mm Example 580 mm 520 mm 490 mm 360 mm 20 mm 920 mm Assembly 1 Calculate correct cutout dimensions 2 Prepare cutout in the worktop 3 One by one place the hobs on a soft surface for example on a blanket with the bottom side up 4 Attach the supplied seal stripe to the lower edge of the hob along the outer edge of the glass ce...

Page 11: ...cess in case a technical assistance intervention is necessary Kitchen unit with door min 20 mm max 150 mm 30 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit 4 PRODUCT DESCRIPTION 4 1 Cooking surface layout 1 2 3 1 Rapid burner 2 A...

Page 12: ...ouple warm up If not the gas supply is interrupted 3 Adjust the flame after it is regular If after some tries the burner does not light check if the crown and its cap are in correct positions WARNING Do not keep the control knob pushed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into off position and try to light the burner again after mi...

Page 13: ... to the control knob otherwise the flame heats the control knob up CAUTION Make sure that pot handles are not above the front edge of the cooktop CAUTION Make sure that the pots are placed centrally on the burner in order to get the maximum stability and a lower gas consumption CAUTION Liquids spilt during cooking can cause the glass to break 6 2 Energy saving If it is possible always put the lids...

Page 14: ...ary remove stubborn stains with a paste cleaner 3 After you clean the pan supports make sure that they are in correct positions 4 For the burner to operate correctly make sure that the arms of the pan supports are aligned with the centre of the burner 7 3 Removing pan supports To keep the pan supports in the correct position they are put on metal pins installed in the rear side of the hob For easi...

Page 15: ...o if Problem Possible cause Remedy There is no spark when you try to activate the spark gen erator The hob is not connected to an electrical supply or it is connected incorrectly Check if the hob is correctly connected to the electrical supply The fuse is blown Make sure that the fuse is the cause of the malfunction If the fuse is blown again and again contact a quali fied electrician Burner cap a...

Page 16: ...NO SER NO DATA MOD PROD NO SER NO 03 IT MADE IN ITALY TYPE IP20 0049 A B C A Stick it on Guarantee Card and send this part if applicable B Stick it on Guarantee Card and keep this part if applicable C Stick it on instruction booklet 9 TECHNICAL DATA 9 1 Hob dimensions Width 360 mm Depth 520 mm 9 2 Bypass diameters BURNER Ø BYPASS 1 100 mm Rapid 45 Auxiliary 30 www aeg com 16 ...

Page 17: ...70 9 5 Gas burners for LPG G30 G31 30 30 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK NOMINAL GAS FLOW g h Rapid 2 45 0 95 79 178 Auxiliary 1 0 0 45 50 73 10 ENVIRONMENTAL CONCERNS Recycle materials with the symbol Put the packaging in relevant containers to recycle it Help protect the environment and human health by recycling waste of electrical and electronic appliances Do not disp...

Page 18: ...www aeg com 18 ...

Page 19: ...ENGLISH 19 ...

Page 20: ...www aeg com shop 867334322 C 432018 ...

Reviews: