‘SETTING AND STARTING A PRO-
GRAMME'.
2.
Press
Multitab
, the Multitab indicator
comes on.
The option stays on until you de-
activate it. Press
Multitab
, the
Multitab indicator goes off.
If you stop to use the combi
detergent tablets, before you start to
use separately detergent, rinse aid
and dishwasher salt, do these steps:
1.
Deactivate the Multitab option.
2.
Set the water softener to the highest
level.
3.
Make sure that the salt container and
the rinse aid dispenser are full.
4.
Start the shortest programme with a
rinsing phase, without detergent and
without dishes.
5.
Adjust the water softener to the wa-
ter hardness in your area.
6.
Adjust the released quantity of rinse
aid.
6.
BEFORE FIRST USE
1.
Make sure that the set level of the
water softener agrees with the water
hardness in your area. If not, adjust
the water softener. Contact your local
water authority to know the water
hardness in your area.
2.
Fill the salt container.
3.
Fill the rinse aid dispenser.
4.
Open the water tap.
5.
Processing residues can stay in the
appliance. Start a programme to re-
move them. Do not use detergent
and do not load the baskets.
If you use the combi detergent
tablets, activate the multitab op-
tion.
6.1
Adjusting the water softener
Water hardness
Water softener
adjustment
German
degrees
(°dH)
French
degrees
(°fH)
mmol/l
Clarke
degrees
Manual
Elec-
tronic
51 - 70
91 - 125
9.1 - 12.5
64 - 88
2
1)
10
43 - 50
76 - 90
7.6 - 9.0
53 - 63
2
1)
9
37 - 42
65 - 75
6.5 - 7.5
46 - 52
2
1)
8
29 - 36
51 - 64
5.1 - 6.4
36 - 45
2
1)
7
23 - 28
40 - 50
4.0 - 5.0
28 - 35
2
1)
6
19 - 22
33 - 39
3.3 - 3.9
23 - 27
2
1)
5
1)
15 - 18
26 - 32
2.6 - 3.2
18 - 22
1
4
11 - 14
19 - 25
1.9 - 2.5
13 - 17
1
3
4 - 10
7 - 18
0.7 - 1.8
5 - 12
1
2
< 4
< 7
< 0.7
< 5
1
2)
1
2)
1)
Factory position.
8