Installation Instructions
109
INSTALLATION INSTRUCTIONS
1
Important!
This appliance must be installed by qualified personnel,
according to the manufacturer’s instructions and to the relevant coun-
try standards.
Please observe this instruction, otherwise the warranty will not cover
any damage that may occur.
Technical Data
Appliance Dimensions
Width
761 mm
Depth
501 mm
Height
47 mm
Cut-Out Dimensions
Width
750
+2
mm
Depth
490 mm
Corner radius
R3
Power Consumption
Induction cooking zone ø 145 mm
1400 W
Induction cooking zone ø 180 mm
1800 W
Induction cooking zone ø 210 mm
2200 W
Induction cooking zone ø 210 mm (P)
3000 W
Heating element voltage
230 V ~
Total connected load max.
7.2 kW