8

12. Trouble-shooting

Fault

Cause

Solution

No hot water

-  The water flow volume     
   required for the unit 
   to turn on has not been 
   reached.
- Flow volume too low.
-  Circuit breaker off
- Safety thermal cut-out  trip

- Increase flow volume.
- Turn breaker on
- Reset thermal cut-out

The unit is not being switched 
on. Electricity supply and flow 
available.

The water flow volume 
required for the unit to turn 
on has not been reached.
- Filter in the cold water  
  connection pipe blocked 
  with dirt.

- Clean the filter after shut-
  ting off the cold  water 
  intake

Water not hot enough

-  Water flow too high
-  Heating setting too low

-  Reduce water flow
-  Turn knob to the right    
   (max. position)

11. Guarantee

For guarantees please refer to the respec-
tive  terms  and    conditions  of  supply  for 
your country.

 

  The installation, electrical

 

  connection and first operation of 

this appliance should be carried out by a 
qualified installer.

The company does not accept liability  
for failure of any good supplied which 
have not been installed and operated 
in accordance with the manufacturer’s 
instructions.

Installation instructions

 

for the user and the qualitified installer

Summary of Contents for BMU 60

Page 1: ...WATER HEATER MODEL BMU 60 OPERATION AND INSTALLATION INSTRUCTIONS ADVANCED ENGINEERING FROM GERMANY ...

Page 2: ...ctions to the new user This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Thiswaterh...

Page 3: ...Fig 1 Fig 2 Functions Dimension Fig 3 Fig 4 Fixing method Electrical connection Pipework Installation 9 3 1 Installation instructionsfor the qualitified installer ...

Page 4: ...4 Fig 5 Fig 6 Description of the unit Wiring Diagram 1 Installation instructionsfor the qualitified installer ...

Page 5: ...rcuit breaker with correct capacity Fitting for open outlet units are not permitted Safety valves are not required Additional Safety If for any reason excessive heating occurs the manual reset thermostat will cut off power permanently Customer must call for service from the qualified technician 3 Care and Maintenance All that is needed for the housing is a damp cloth Do not use any abrasive leanin...

Page 6: ... to the cold water inlet of the unit 5 Tighten the union nut to the warm water outlet of the unit 6 8 Straightentheunitandtightenthescrews 9 Connect the electrical supply 10 Fit the cover and secure with the screw 11 Turn the rotary control to the left and right internal setting lever will engage 8 First operation Only to be carried out by a qualified installer Before switching on set the rotary t...

Page 7: ...r BMU Type 60 Design Flow switch type Rate content l 0 5 Water connection G 1 2 External thread Electrical connection 1 N PE 220 240 V Recomended circuit breaker A 32 Recomended cable size Spmm 4 6 Rated power kW Rate current A kW A 220 V 60 27 3 230 V 6 6 28 7 240 V 7 1 29 6 ...

Page 8: ...ked with dirt Clean the filter after shut ting off the cold water intake Water not hot enough Water flow too high Heating setting too low Reduce water flow Turn knob to the right max position 11 Guarantee For guarantees please refer to the respec tive terms and conditions of supply for your country The installation electrical connectionandfirstoperation of this appliance should be carried out by a...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...SIZE A5 MATERIAL GREEN READ PAPER 75 G PLASTIC BAG 7 x 11 INCH PART NO 7901 269462 PART NAME MANUAL BMU Rev 03 Product code BMU 60 220841 ...

Reviews: