background image

5

1. Description of the unit

  The  

BMU

  flow-controlled  instataneous

water  heater  heats  the  water  while  it  is
flowing trough the unit.  The heating power 
is switched on automatically in the event of 
the minimum flow rate being exceeded.
The “Power” light indicates that heating
system is switched on.

  The input of heat into the water is
electronically controlled.   Please set the
desired  heat  input  by  using  the  knob  on 
the front cover.

  In addition the outlet temperature can 
be controlled at the draw off point.

Description of the unit

  1. Connection cable
  2. Cable duct for electrical connection
  3. Power Light
  4. Rotary contron for temperature 
      adjustement
  5. Cold water connection
  6. Hot water connection
  7. Lower fixing hole
  8. Upper fixing hole
  9. Depth for electrial connection
10. Combination filter/seal
 

2. Important information

  -  Currently-applicable data on the supply 
    rating plate.
  -  Install the unit flush with the wall.
  -  Piped supplementary heating is not 
    permissible.
  -  Water installation material: 
    Cold water pipe: -steel or copper.
    Hot water pipe: -copper.
  -  Electrical connection to permanently-
    installed leads via a circuit breaker with 
    correct capacity. 
  - Fitting for open-outlet units are not 

    permitted.
  - Safety valves are not required.

Additional Safety.

  If  for  any  reason,  excessive  heating   
occurs the manual reset thermostat will 
cut off power permanently 
* Customer must call for service from the 
qualified technician.

3. Care and Maintenance

  All that is needed for  the housing is  a 
damp cloth.  Do not use any abrasive leaning 
agents or agents containing solvents.

 

Maintenance work may only be 

 

carried out by a qualified installer.

4. Regulations and Provisions

    -  Regulations of the local power supply 
      company should be observed.
    -  Regulations of the water supply 
      company should observed
    -  Technical data.
    -  Install the unit flush with the wall.
    -  Electrical connection to be secure.
    -  The device must be capable of being 
      isolated from the mains, for  example 
      by fuses, with an isolating distance of 
      at least 3.5 mm, in  all poles.

 

The unit must be earthed (see 

 

circuit diagram).   To protect    

against water penetration, the cable seal 
(2) must be used.

5. Important note

 

All the information in these 

 

operating and installation 

instructions must be carefully followed.  
These instructions provide important 
details regarding the safety, operation,
installation, and maintenance of the unit.

Installation instructions

 

for the user and the qualitified installer

Summary of Contents for BMU 60

Page 1: ...WATER HEATER MODEL BMU 60 OPERATION AND INSTALLATION INSTRUCTIONS ADVANCED ENGINEERING FROM GERMANY ...

Page 2: ...ctions to the new user This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Thiswaterh...

Page 3: ...Fig 1 Fig 2 Functions Dimension Fig 3 Fig 4 Fixing method Electrical connection Pipework Installation 9 3 1 Installation instructionsfor the qualitified installer ...

Page 4: ...4 Fig 5 Fig 6 Description of the unit Wiring Diagram 1 Installation instructionsfor the qualitified installer ...

Page 5: ...rcuit breaker with correct capacity Fitting for open outlet units are not permitted Safety valves are not required Additional Safety If for any reason excessive heating occurs the manual reset thermostat will cut off power permanently Customer must call for service from the qualified technician 3 Care and Maintenance All that is needed for the housing is a damp cloth Do not use any abrasive leanin...

Page 6: ... to the cold water inlet of the unit 5 Tighten the union nut to the warm water outlet of the unit 6 8 Straightentheunitandtightenthescrews 9 Connect the electrical supply 10 Fit the cover and secure with the screw 11 Turn the rotary control to the left and right internal setting lever will engage 8 First operation Only to be carried out by a qualified installer Before switching on set the rotary t...

Page 7: ...r BMU Type 60 Design Flow switch type Rate content l 0 5 Water connection G 1 2 External thread Electrical connection 1 N PE 220 240 V Recomended circuit breaker A 32 Recomended cable size Spmm 4 6 Rated power kW Rate current A kW A 220 V 60 27 3 230 V 6 6 28 7 240 V 7 1 29 6 ...

Page 8: ...ked with dirt Clean the filter after shut ting off the cold water intake Water not hot enough Water flow too high Heating setting too low Reduce water flow Turn knob to the right max position 11 Guarantee For guarantees please refer to the respec tive terms and conditions of supply for your country The installation electrical connectionandfirstoperation of this appliance should be carried out by a...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...SIZE A5 MATERIAL GREEN READ PAPER 75 G PLASTIC BAG 7 x 11 INCH PART NO 7901 269462 PART NAME MANUAL BMU Rev 03 Product code BMU 60 220841 ...