12
13
B4-1050 Super Torque
.......................1050 W
.........................525 W
.........................220 min
-1
.........................250 min
-1
.........................350 min
-1
.........................420 min
-1
......................... 115 min
-1
.........................160 min
-1
.........................190 min
-1
.........................260 min
-1
...........................32 mm
...........................64 mm
...........................52 mm
...................... MK 3
...........................57 mm
..........................7,5 kg
...........................85 dB (A)
...........................96 dB (A)
...........................12 m/s
2
..........................2,9 m/s
2
ENGLISH
ENGLISH
TECHNICAL DATA
Rotary Drill
Rated input ..............................................................................
Output ......................................................................................
No-load speed, 1st gear ..........................................................
No-load speed, 2nd gear .........................................................
No-load speed, 3rd gear ..........................................................
No-load speed, 4th gear ..........................................................
Speed under load max., 1st gear ............................................
Speed under load max., 2nd gear ...........................................
Speed under load max., 3rd gear ............................................
Speed under load max., 4th gear ............................................
Drilling capacity in steel ...........................................................
Drilling capacity in Aluminium ..................................................
Drilling capacity in soft- wood ..................................................
Chuck reception morse taper ..................................................
Chuck neck diameter ...............................................................
Weight according EPTA-Procedure 01/2003 ...........................
Noise Information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level (K = 3 dB(A)) ............................................
Wear ear protectors!
Vibration Information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
h
: ....................................................
Uncertainty K = .......................................................................
Measured values determined according to EN 60 745.
The data stated above apply for models with 230 - 240 V.In
case of deviating mains voltage, the data stated on the rating
plate are applicable.
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure
. Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors.
Exposure to noise can cause hearing
loss.
Use auxiliary handles supplied with the tool.
Loss of control
can cause personal injury.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory may
contact hidden wiring or its own cord.
Cutting accessory
contacting a „live“ wire may make exposed metal parts of the
power tool „live“ and could give the operator an electric shock.
Appliances used at many different locations including open air
should be connected via a residual current device of 30 mA or
less.
Always wear goggles when using the machine. It is
recommended to wear gloves, sturdy non slipping shoes and
apron.
Sawdust and splinters must not be removed while the machine
is running.
Always disconnect the plug from the socket before carrying out
any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
When working with large drill diameters, the auxiliary handle
must be fastened in a right angle with the main handle (see
illustrations, section „Twisting the handle“).
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
SPECIFIED CONDITIONS OF USE
The drill can be used for drilling in wood, metal and plastics.
Do not use this product in any other way as stated for normal
use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also possible
to connect to sockets without an earthing contact as the design
conforms to safety class
II
.
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in
EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the
exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is
running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in
conformity with the following standards or standardized
documents.
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
in accordance with the regulations
2011/65/EU (RoHs)
2006/42/EC
2004/108/EC
Winnenden, 2012-11-12
Rainer Kumpf
Director Product Development
Authorized to compile the technical file
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
Use only AEG accessories and AEG spare parts. Should
components need to be replaced which have not been
described, please contact one of our AEG service agents (see
our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the ten-digit No. as well as the machine type printed on
the label and order the drawing at your local service agents or
directly at: AEG Electric Tools GmbH, Max-Eyth-Straße 10,
D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions
carefully before starting the
machine.
Always disconnect the plug from the socket
before carrying out any work on the
machine.
Accessory - Not included in standard
equipment, available as an accessory.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national
law, electric tools that have reached the end
of their life must be collected separately and
returned to an environmentally compatible
recycling facility.
Class II construction, tool in which protection
against electric shock does not rely on basic
insulation only, but in which additional safety
precautions, such as double insulation or
reinforced insulation, are provided.