--------------------------------------------------------------------------------16/45--------------------------------------------------------------------------------
3.3
Instructions for reading settings
3.3.1
CE – convert error code
With CE=1 the reader sends no error codes, except the no read error, during the md0 mode or the
commands Get Tag.
With CE=2 the reader sends the normal no read error (XXXXXXXX) if there is an error with the se-
lect or anticollision.
This command has only effect in the ISO 14443A standard.
Input format:
CE
<SP>
parameter
<CR>
Output (example):
0
<CR>
Parameter:
PARAMETER
FUNCTION
0
No suppression
1
Suppression of error codes
2
Replacement with XXXXXXXX
3.3.2
CID – suppression of ID Codes
In the MD0 mode with CID=1
only the first
of in succession identical transponder numbers is output
on the serial interface. The possibly following identical transponder numbers are suppressed, as long
as no new valid transponder number is received, processed and output. The get tag command is not
influenced by this command. NoReads do not influence the data filtering.
Input format:
CID
<SP>
parameter
<CR>
Output (example):
0
<CR>
Parameter:
PARAMETER
FUNCTION
0
No suppression
1
Suppression of equal transponder numbers
Example: A, B, C are different transponder codes, N is NoRead error code: