3.4.11
VSAVE
VSAVE – Save parameter permanently in ARE i9 flash memory
VSAVE is used to save parameters permanently in flash memory of ARE i9 to be available after power on.
Input format:
VSAVE <CR>
Hex:
56
53
41
56
45
0D
ASCII:
‘V’
‘S’
‘A’
’V’
‘E’
<CR>
Output (example): OK<CR>
Hex:
4F
4B
0D
ASCII:
‘O’
‘K’
<CR>
3.4.12
INIT
INIT – Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the
parameters.
Input format: INIT<CR>
Hex:
49
4E
49
54
0D
ASCII:
‘I’
‘N’
‘I’
’T’
<CR>
Output (example): OK<CR>
Hex:
4F
4B
0D
ASCII:
‘O’
‘K’
<CR>
The following parameters are set:
TOR 50
LRD 01001
MD 2
LNRD 10001
CID 0
LERR 10011
CN 0
LED 1
LSTB 01101
LRT 30
LGT 01111
LPA 00000