![AEG ACM 9 Manual Download Page 29](http://html.mh-extra.com/html/aeg/acm-9/acm-9_manual_3048210029.webp)
Manual ACM 9 - ARE i9 release
Version: 10
Page: 29 / 51
Manual ACM9_ARE i9 release V10.docx
The following parameters are set:
TOR 50
LRD 01001
MD 2
LNRD 10001
CID 0
LERR 10011
CN 0
LED 1
LSTB 01101
LRT 30
LGT 01111
LPA 00000
3.3.14
Error messages
Error messages and protocol errors are acknowledged by ARE i9 using an error code. The format is described below:
<NAK> '#' <error code> <CR>
Example error #02 (wrong parameter)
Hex:
15
23
30
32
0D
ASCII:
<NAK>
‘#’
‘0’
’2’
<CR>
The error code is comprised of a two digit ASCII coded number. Please note that for communication through ACM 9, the
appropriate reader number is preceding the error message.
The following table displays possible error messages:
Error code
Meaning
"00"
Unknown instruction
"02"
Wrong parameter