to completely eliminate certain residual risk factors. The following 
hazards may arise and the operator should pay special attention to 
avoid the following:

 

Ŷ

Use the product only for its intended use. Do not alter or modify 
the product from the original design or function.

 

Ŷ

Always be aware that misuse and improper handling of the 
product can cause injury to yourself and others.

 

Ŷ

Never leave an air compressor unattended with the hose attached 
to a tool.

 

Ŷ

Do not continue to use an air compressor or hose which leaks air 
or does not function properly.

 

Ŷ

Risk of bursting

 

Do not adjust regulator to result in output pressure greater 
than marked maximum pressure of attachment.

 

Ŷ

Heat and high temperature are generated while motor and 
cylinder are running. Touching exposed metal can result in 
serious burns.

 

Always keep the air compressor away from the working zones.

 

Ŷ

Injury casued by noise

 

Wear ear protection.

 

Ŷ

The gas from air compressor can propel dirt, chips, loose particles 
and small objects at high speed. This may result in objects being 
thrown into eyes or other possible serious injury.

 

Always wear proper personal protective equipment when 
operating different tools.

SPECIFIED CONDITIONS OF USE

This compressor is designed to supply pressurised air only. It must 
not be used to compress any other gas. It is designed to operate air 
powered tools. The compressor should be operated indoors only.

ASSEMBLY

UNPACKING

This product requires assembly. Carefully remove the product and 
any accessories from the box.

 

 WARNING

Do not use this product if any parts on the packing list are already 
assembled to your product when you unpack it. Parts on this 
list are not assembled to the product by the manufacturer and 
require customer installation. Use of a product that may have been 
improperly assembled could result in serious personal injury.

Inspect the product carefully to make sure no breakage or damage 
occurred during shipping.

Do not discard the packing material until you have carefully 
inspected and satisfactorily operated the product.

 

 WARNING

If any parts are damaged or missing do not operate this product 
until the parts are replaced. Use of this product with damaged or 
missing parts could result in serious personal injury.

 

 WARNING

Do not attempt to modify this product or create accessories not 
recommended for use with this product. Any such alteration or 
modification is misuse and could result in a hazardous condition 
leading to possible serious personal injury.

 

 WARNING

Do not connect to power supply until assembly is complete. Failure 
to comply could result in accidental starting and possible serious 
personal injury.

Packing list

 

Air compressor

 

Front handle

 

Air filter x 4

 

Wheel x 2

 

Rubber foot x 2

 

M10 Step bolt x 2

 

M8 bolt x 2

 

Front handle locking bolt x 2

 

M10 hex nut x 2

 

M8 hex nut x 2

 

M10 x 4 mm flat washer x 2

 

M10 x 1.5 mm flat washer x 2

 

M8 flat washer x 4

 

M10 spring washer x 2

 

Operator’s manual

INSTALLING FRONT HANDLE

See figure 2.

1. 

Insert both ends of the front handle in handle slots.

2.  Align the holes on the front handle and handle slots. Secure both 

ends with locking bolts and hand tighten.

INSTALLING FEET

See figure 3.

1.  Place a rubber foot under the left supporting frame at the front. 

Align the screw holes.

2.  Insert an M8 bolt and M8 flat washer in the holes in the rubber 

foot and the supporting frame from the bottom.

3.  Insert an M8 flat washer at the other end.

4.  Secure the rubber foot with an M8 hex nut.

5.  Repeat the above steps to install the other foot on the right.

6.  Ensure the compressor is stable by gently applying lateral force 

on it.

INSTALLING WHEELS

See figure 4.

1. 

Insert an M10 step bolt in the centre hole of the wheel.

2.  Insert the threaded section of the step bolt in the hole in the rear 

brace on the left. Place a 4 mm washer between the wheels and 
frame, and place a 1.5 mm washer on the inside of the frame. 

3.  Insert a spring washer .

4.  Secure the step bolt with an M10 hex nut.

5.  Repeat the above steps to install the other wheel on the right.

6.  Ensure the compressor is stable by gently applying lateral force 

on it.

INSTALLING AIR FILTERS

See figure 5.

Attach one air filter to each of the cylinder covers. Screw in a clockwise 
direction to fasten securely.

Summary of Contents for AC3060S

Page 1: ...AC3060S Original instructions ...

Page 2: ...2 2 Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modifications ...

Page 3: ...3 Tank pressure gauge 4 Regulator pressure gauge 5 Quick connect coupler 6 Pressure regulator knob 7 Pressure relief valve 8 Front handle 9 Rubber foot x2 10 Drain valve 11 Wheel x2 1 2 4 2 1 2 3 3 1 1 Fig 2 Fig 1 Fig 4 Fig 5 Fig 3 6 2 7 4 5 3 10 9 11 8 1 1 1 Wheel 2 M10 step bolt 3 M10 Washer 4mm 4 M10 Washer 1 5mm 5 Spring washer 6 M10 hex nut 5 4 6 3 1 2 ...

Page 4: ...erclockwise 4 Pressure relief valve 5 Pressure regulator locking ring 1 Quick connect air fitting 2 Quick coupler 1 Regulated pressure gauge 2 Tank pressuse gauge 3 To open clockwise 4 Pressure regulator locking ring 2 1 1 2 3 3 5 4 2 4 1 2 Fig 7 Fig 8 Fig 6a Fig 6b Fig 9 1 ...

Page 5: ...5 5 1 Ring 2 Pressure relief valve 1 Air filter housing 2 Air filter 3 Air filter cover 1 Drain valve 2 To close 3 To open 2 1 3 2 1 Fig 12 Fig 10 Fig 11 1 2 3 ...

Page 6: ...es of wood on the tool while it is in operation Ŷ Do not use in dangerous environments Do not use power tools in damp or wet locations or expose to rain Keep the work area well lit Ŷ Keep children and visitors away All visitors should wear safety glasses and be kept a safe distance from work area Do not let visitors contact tool or extension cord while operating Ŷ Never use in an explosive atmosph...

Page 7: ... Never leave a tool unattended with the air hose attached Ŷ Never point any air tool toward yourself or others Ŷ Do not operate this air compressor if it does not contain a legible warning label Ŷ Do not continue to use a tool or hose that leaks air or does not function properly Ŷ Always disconnect the air supply and power supply before making adjustments servicing a product or when a product is n...

Page 8: ... and satisfactorily operated the product WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create accessories not recommended for use with this product Any such alteration or modification is misuse and could re...

Page 9: ...ompressor Make sure to push the hose adapter end fully into the coupler until the sleeve springs forward to lock it in place To disconnect an air hose or an air tool 1 Rotate pressure regulator knob fully counterclockwise 2 Confirm that the outlet pressure is at zero 0 bar 3 When disconnecting a hose from 6 35 mm 1 4 in quick coupler always firmly hold release end of hose 4 Pull back on the releas...

Page 10: ... tank of the compressor should be drained daily To drain 1 Turn the air compressor off 2 Pull the ring on the pressure relief valve to release until pressure gauge reads less than 1 4 bar 3 Release the ring 4 Turn the drain valve counterclockwise to open and drain the moisture NOTE Condensate is a polluting material and should be disposed of in compliance with local regulations 5 If drain valve is...

Page 11: ...an exploded view of the product can be ordered Please state the Article No as well as the machine type printed on the label and order the drawing at your local service agents or directly at Techtronic Industries Australia Pty Ltd PO Box 1065 Mount Waverley VIC 3149 Tel no 1300 234 797 Australia Techtronic Industries N Z Limited 70 Business Parade South Highbrook Auckland 2013 Tel no 0800 234 797 N...

Page 12: ...ck with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge wire and cord length Air tank pressure drops when compressor shuts off Loose connections fittings tubing etc Check all connections with soap and water solution and tighten Loose drain valve Tighten drain valve Check valve...

Page 13: ...13 13 PARTS LIST ...

Page 14: ...ia 10 25 Drain cock 1 13 Cylinder head 1 44 Bearing 6204 26 Bolt M8 25 1 14 Bolt M6 70 1 45 Cover B 27 Washer 1 15 Spring Dia 6 1 46 Bolt M5 25 28 Cushion foot 1 16 Bolt M4 16 1 47 Vibration column M8 29 Washer 1 17 Head cover 1 48 Nut M8 30 Nut 1 18 Fixed block 1 49 Capacitor 35uf 31 Switch assembly 1 19 Obturating ring 1 50 Motor electrical wire 31 1 Pressure switch 1 20 Connecting pipe 2 Pipe 3...

Page 15: ...r Pressure switch L N Main winding Aux winding Capacitor Capacitor Main winding Aux winding Motor 1 Thermal protector 220V 240V Input power 1100W x 2 Main winding 1 05 mm Aux winding 1 0 mm Working capacitor 450V 35uf Input power 1 1 kW x 2 Power cable 1 0 mm 1 5 mm Motor Kelly bracket Motor bracket GND GND ...

Page 16: ...averley VIC 3149 Australia Techtronic Industries N Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand www aegpowertools com au www aegpowertools co nz 20190326v1b AEG is a registered trademark used under license from AB Electrolux publ ...