GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most plastics are 
susceptible to damage from various types of commercial solvents and 
may be damaged by their use. Use clean cloths to remove dirt, dust, 
oil, grease, etc.

Do not modify this product in any way or use accessories not 
approved by the manufacturer. Your safety and that of others may 
be compromised.

Disconnect the power supply before making adjustments or when 
doing any maintenance on the machine.

 

 WARNING

Do not at any time let brake fluids, gasoline, petroleum-based 
products, penetrating oils, etc., come in contact with plastic parts. 
Chemicals can damage, weaken or destroy plastic which may result 
in serious personal injury.

REPLACING AIR FILTERS

See figure 12.

Follow the instructions below to replace the air filters:

Normal environment

Check and clean the filters once a month. Replace damaged or heavily 
clogged filters.

Heavy-dust environment

Check and clean the filters once a week. Replace damaged or heavily 
clogged filters.

To replace an air filter:

1. 

Remove the air filter by turning counterclockwise.

2.  Attach a new air filter and rotate clockwise to secure.

 

 WARNING

For greater safety and reliability, all repairs should be performed by 
an authorised AEG service centre.

Use only AEG accessories and spare parts. Should components need 
to be replaced which have not been described, please contact one of 
our AEG service agents (see our list of guarantee/service addresses).

If needed, an exploded view of the product can be ordered. Please 
state the Article No. as well as the machine type printed on the label 
and order the drawing at your local service agents or directly at: 

Techtronic Industries Australia Pty Ltd

PO Box 1065 
Mount Waverley VIC 3149 
Tel. no. 1300 234 797 
Australia

Techtronic Industries N.Z. Limited

70 Business Parade South 
Highbrook 
Auckland 2013 
Tel no. 0800 234 797 
New Zealand

SYMBOLS

Safety alert

Please read the instructions carefully before starting 
the machine.

Always wear goggles when using the machine.

Wear ear protectors.

Regulatory Compliance Mark (RCM). Product meets 
applicable regulatory requirements.

Indoor use

Wet condition alert. Do not expose to rain. Store 
indoors.

Risk of breathing. Air obtained directly from the air 
compressor should never be used to supply air for 
human consumption.

Risk of bursting. Do not adjust regulator to result 
in output pressure greater than marked maximum 
pressure of attachment. Do not use at pressure 
greater than 10 bar.

Hot surface: To reduce the risk of injury or damage, 
avoid contact with any surface.

This compressor may start without warning.

Risk of fire or explosion.

 Spray area must be well 

ventilated. Do not smoke while spraying or spray 
where spark or flame is present. Keep compressors 
as far from the spraying area as possible. Keep 
compressor, at least 10 m from the spraying area 
and all explosive vapours.

Caution, risk of electric shock

Do not dispose of electric tools together with 
household waste material. Electric tools and 
electronic equipment that have reached the end of 
their life must be collected separately and returned 
to an environmentally compatible recycling facility.

Summary of Contents for AC3060S

Page 1: ...AC3060S Original instructions ...

Page 2: ...2 2 Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modifications ...

Page 3: ...3 Tank pressure gauge 4 Regulator pressure gauge 5 Quick connect coupler 6 Pressure regulator knob 7 Pressure relief valve 8 Front handle 9 Rubber foot x2 10 Drain valve 11 Wheel x2 1 2 4 2 1 2 3 3 1 1 Fig 2 Fig 1 Fig 4 Fig 5 Fig 3 6 2 7 4 5 3 10 9 11 8 1 1 1 Wheel 2 M10 step bolt 3 M10 Washer 4mm 4 M10 Washer 1 5mm 5 Spring washer 6 M10 hex nut 5 4 6 3 1 2 ...

Page 4: ...erclockwise 4 Pressure relief valve 5 Pressure regulator locking ring 1 Quick connect air fitting 2 Quick coupler 1 Regulated pressure gauge 2 Tank pressuse gauge 3 To open clockwise 4 Pressure regulator locking ring 2 1 1 2 3 3 5 4 2 4 1 2 Fig 7 Fig 8 Fig 6a Fig 6b Fig 9 1 ...

Page 5: ...5 5 1 Ring 2 Pressure relief valve 1 Air filter housing 2 Air filter 3 Air filter cover 1 Drain valve 2 To close 3 To open 2 1 3 2 1 Fig 12 Fig 10 Fig 11 1 2 3 ...

Page 6: ...es of wood on the tool while it is in operation Ŷ Do not use in dangerous environments Do not use power tools in damp or wet locations or expose to rain Keep the work area well lit Ŷ Keep children and visitors away All visitors should wear safety glasses and be kept a safe distance from work area Do not let visitors contact tool or extension cord while operating Ŷ Never use in an explosive atmosph...

Page 7: ... Never leave a tool unattended with the air hose attached Ŷ Never point any air tool toward yourself or others Ŷ Do not operate this air compressor if it does not contain a legible warning label Ŷ Do not continue to use a tool or hose that leaks air or does not function properly Ŷ Always disconnect the air supply and power supply before making adjustments servicing a product or when a product is n...

Page 8: ... and satisfactorily operated the product WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create accessories not recommended for use with this product Any such alteration or modification is misuse and could re...

Page 9: ...ompressor Make sure to push the hose adapter end fully into the coupler until the sleeve springs forward to lock it in place To disconnect an air hose or an air tool 1 Rotate pressure regulator knob fully counterclockwise 2 Confirm that the outlet pressure is at zero 0 bar 3 When disconnecting a hose from 6 35 mm 1 4 in quick coupler always firmly hold release end of hose 4 Pull back on the releas...

Page 10: ... tank of the compressor should be drained daily To drain 1 Turn the air compressor off 2 Pull the ring on the pressure relief valve to release until pressure gauge reads less than 1 4 bar 3 Release the ring 4 Turn the drain valve counterclockwise to open and drain the moisture NOTE Condensate is a polluting material and should be disposed of in compliance with local regulations 5 If drain valve is...

Page 11: ...an exploded view of the product can be ordered Please state the Article No as well as the machine type printed on the label and order the drawing at your local service agents or directly at Techtronic Industries Australia Pty Ltd PO Box 1065 Mount Waverley VIC 3149 Tel no 1300 234 797 Australia Techtronic Industries N Z Limited 70 Business Parade South Highbrook Auckland 2013 Tel no 0800 234 797 N...

Page 12: ...ck with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge wire and cord length Air tank pressure drops when compressor shuts off Loose connections fittings tubing etc Check all connections with soap and water solution and tighten Loose drain valve Tighten drain valve Check valve...

Page 13: ...13 13 PARTS LIST ...

Page 14: ...ia 10 25 Drain cock 1 13 Cylinder head 1 44 Bearing 6204 26 Bolt M8 25 1 14 Bolt M6 70 1 45 Cover B 27 Washer 1 15 Spring Dia 6 1 46 Bolt M5 25 28 Cushion foot 1 16 Bolt M4 16 1 47 Vibration column M8 29 Washer 1 17 Head cover 1 48 Nut M8 30 Nut 1 18 Fixed block 1 49 Capacitor 35uf 31 Switch assembly 1 19 Obturating ring 1 50 Motor electrical wire 31 1 Pressure switch 1 20 Connecting pipe 2 Pipe 3...

Page 15: ...r Pressure switch L N Main winding Aux winding Capacitor Capacitor Main winding Aux winding Motor 1 Thermal protector 220V 240V Input power 1100W x 2 Main winding 1 05 mm Aux winding 1 0 mm Working capacitor 450V 35uf Input power 1 1 kW x 2 Power cable 1 0 mm 1 5 mm Motor Kelly bracket Motor bracket GND GND ...

Page 16: ...averley VIC 3149 Australia Techtronic Industries N Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand www aegpowertools com au www aegpowertools co nz 20190326v1b AEG is a registered trademark used under license from AB Electrolux publ ...

Reviews: