background image

12

12

 

 WARNING

For greater safety and reliability, all repairs should be performed by 
an authorised AEG service centre.

Use only AEG accessories and spare parts. Should components need 
to be replaced which have not been described, please contact one of 
our AEG service agents (see our list of guarantee/service addresses).

If needed, an exploded view of the product can be ordered. Please 
state the Article No. as well as the machine type printed on the label 
and order the drawing at your local service agents or directly at: 

Techtronic Industries Australia Pty Ltd

PO Box 1065 
Mount Waverley VIC 3149 
Tel. no. 1300 234 797 
Australia

Techtronic Industries N.Z. Limited

PO Box 12-806 
Penrose AUCKLAND 1642 
Tel no. 0800 234 797 
New Zealand

SYMBOLS

Safety alert

Please read the instructions carefully before starting 
the machine.

Always wear goggles when using the machine.

Wear ear protectors.

Regulatory Compliance Mark (RCM). Product meets 
applicable regulatory requirements.

Indoor use

Wet condition alert. Do not expose to rain. Store 
indoors.

Risk of breathing. Air obtained directly from the air 
compressor should never be used to supply air for 
human consumption.

Risk of bursting. Do not adjust regulator to result 
in output pressure greater than marked maximum 
pressure of attachment. Do not use at pressure 
greater than 8 bar.

Hot surface: To reduce the risk of injury or damage, 
avoid contact with any surface.

This compressor may start without warning.

Risk of fire or explosion.

 Spray area must be well 

ventilated. Do not smoke while spraying or spray 
where spark or flame is present. Keep compressors 
as far from the spraying area as possible. Keep 
compressor, at least 10 m from the spraying area 
and all explosive vapours.

Caution, risk of electric shock

Do not dispose of electric tools together with 
household waste material. Electric tools and 
electronic equipment that have reached the end of 
their life must be collected separately and returned 
to an environmentally compatible recycling facility.

Summary of Contents for AC3050B

Page 1: ...AC3050B Original instructions ...

Page 2: ...2 2 Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modifications ...

Page 3: ...ressure gauge 7 Quick connect coupler 8 Pressure regulator knob 9 Pressure relief valve 10 Rubber foot x2 11 Drain valve 12 Wheel x2 13 Oil drain plug 14 Oil level indicator 15 Overload reset button 16 Belt 17 Guard 18 Breather 1 2 4 2 1 2 3 3 1 Fig 2 Fig 1 Fig 4 Fig 5 Fig 3 8 9 6 7 5 11 14 13 10 12 15 1 4 16 17 3 1 Wheel 2 M10 step bolt 3 M10 Washer 4mm 4 M10 Washer 1 5mm 5 Spring washer 6 M10 he...

Page 4: ...To close counterclockwise 4 Pressure relief valve 5 Pressure regulator locking ring 1 Quick connect air fitting 2 Quick coupler 1 Regulated pressure gauge 2 Tank pressuse gauge 3 To open clockwise 4 Pressure regulator locking ring 2 2 1 1 2 1 2 3 3 3 5 4 2 4 1 1 2 Fig 7a Fig 7b Fig 6 Fig 8 Fig 9 Fig 10 1 ...

Page 5: ...Ring 2 Pressure relief valve 1 Air filter housing 2 Air filter 3 Air filter cover 1 Drain valve 2 To close 3 To open 1 Reset button 2 1 3 2 1 Fig 15 Fig 13 Fig 14 Fig 11 Fig 12 1 1 2 3 1 Oil drain plug 1 2 1 ...

Page 6: ...f wood on the tool while it is in operation Ŷ Do not use in dangerous environments Do not use power tools in damp or wet locations or expose to rain Keep the work area well lit Ŷ Keep children and visitors away All visitors should wear safety glasses and be kept a safe distance from work area Do not let visitors contact tool or extension cord while operating Ŷ Never use in an explosive atmosphere ...

Page 7: ...l unattended with the air hose attached Ŷ Never point any air tool toward yourself or others Ŷ Do not operate this air compressor if it does not contain a legible warning label Ŷ Do not continue to use a tool or hose that leaks air or does not function properly Ŷ Always disconnect the air supply and power supply before making adjustments servicing a product or when a product is not in use Ŷ Do not...

Page 8: ...sing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create accessories not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury WARNIN...

Page 9: ...on the wheels 3 Push the unit along to the desired location 4 Lower the air compressor until it sits securely on a flat surface To transport the air compressor up or down stairs See figure 7b 1 Grasp the front handle and rear handle firmly Lift the unit into a safe and comfortable carrying position NOTE Use good lifting techniques and get help if needed 2 With proper footing and balance carry the ...

Page 10: ...to tamper with the safety valve Anything loosened from this device could fly up and hit you Failure to heed this warning could result in death or serious personal injury The pressure relief valve will automatically release air if the air tank pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand 1 Turn the air compressor on and allow the...

Page 11: ...r when doing any maintenance on the machine As a routine part of air compressor maintenance it is also advised that the oil is routinely checked for proper levels WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating oils etc come in contact with plastic parts Chemicals can damage weaken or destroy plastic which may result in serious personal injury REPLACING OI...

Page 12: ...ompliance Mark RCM Product meets applicable regulatory requirements Indoor use Wet condition alert Do not expose to rain Store indoors Risk of breathing Air obtained directly from the air compressor should never be used to supply air for human consumption Risk of bursting Do not adjust regulator to result in output pressure greater than marked maximum pressure of attachment Do not use at pressure ...

Page 13: ...ck with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge wire and cord length Air tank pressure drops when compressor shuts off Loose connections fittings tubing etc Check all connections with soap and water solution and tighten Loose drain valve Tighten drain valve Check valve...

Page 14: ...14 14 PARTS LIST ...

Page 15: ...3 16 Stator 24 Block up 1 12 Valve plate 1 43 Bolt 13 17 Rotator 25 Nut 1 13 Gasket 1 44 Bolt 13 18 Bearing 26 Bolt 1 14 Gasket 1 45 Spring 13 19 Bearing crank 27 Washer 1 15 Cylinder head 2 Nut 13 20 Fan 28 Cushion foot 1 16 Metal filter 3 Washer 13 21 Cover 29 Washer 1 17 Bolt 4 Washer 13 22 Bolt 30 Nut 1 18 Head cover 5 Bolt 13 23 Washer 31 Drain cock 1 19 Bolt 6 Bolt 13 24 Bolt 32 Nut 1 20 Spr...

Page 16: ... protector Motor Main winding Aux winding Centrifugal switch Start capacitor 220V 240V INPUT POWER 2200W Main winding 1 0 mm Aux winding 1 05 mm Start capacitor 250V 250uf Working capacitor 450V 40uf Input power 2 2 kW Power cable 1 5 mm CIRCUIT DIAGRAM ...

Page 17: ...17 17 ...

Page 18: ...18 18 ...

Page 19: ...19 19 NITTO is a registered trademark owned by Nitto Kohki Co Ltd ...

Page 20: ...unt Waverley VIC 3149 Melbourne Australia Techtronic Industries N Z Limited 2 Landing Drive Mangere Auckland 2022 New Zealand www aegpowertools com au www aegpowertools co nz 20181105v1 AEG is a registered trademark used under license from AB Electrolux publ ...

Reviews: