25
Installation Instructions
z
Risk of injury from electrical current.
•
Loose and inappropriate plug and socket connections can make the terminal
overheat.
•
Have the clamping connections correctly installed by a qualified electrician.
•
Use strain relief clamp on cable.
•
In the event of single-phase or two-phase connection, the appropriate mains
cable of type H05BB-F Tmax 90°C(or higher) must be used.
•
If this appliance’s mains cable is damaged, it must be replaced by a special ca-
ble (type H05BB-F Tmax 90°C; or higher). The latter is available from the Cus-
tomer Care Department.
A device must be provided in the electrical installation which allows the appli-
ance to be disconnected from the mains at all poles with a contact opening
width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses (screw type fus-
es are to be removed from the holder), earth leakage trips and contactors.