background image

66

Fig. 6

K-S

S

K

Electric hob

600 mm

Gas  hob

700  mm

Charcoal  and  oil 800  mm

Summary of Contents for 2060 D

Page 1: ...0 D Dunstabzugshaube Hotte aspirante Cappa aspirante Cooker hood Montage und Gebrauchsanweisung Notice d utilisation et d installation Istruzioni di montaggio e uso Operating and Installation Instructions ...

Page 2: ...indicator for active carbon filter D 56 Resetting the saturation indicator 56 Maintenance and care 57 Metal grease filter 57 Open the metal grease filter 57 Carbon filter 58 Changing the light bulb 59 Cleaning 60 Special accessories 60 Technical assistance service 60 Technic Details 63 Mounting accessories included 63 Electrical connection 64 Safety warnings for the electrician 64 Wall unit mounti...

Page 3: ...could cause grease deposits to build up causing a fire hazard for kitchen unit installer When used as an extractor unit the hood must be fitted with a 150mm diameter hose Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof it is possible to use the 150 125 mm reduction flange provided In this case the hood will be slightly more noisy When installin...

Page 4: ...2 large to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm2 which is to say a larger hole could reduce the performance of the extractor hoo...

Page 5: ...be a pipe of diameter 125 mm that ducts to the outside through the walls or roof it is possible to use the 150 125 mm reduction flange provided In this case the hood will be slightly more noisy Fig 1 Filter Version The air is filtered through an activated charcoal filter and returned to the kitchen through the top grill of the outlet pipe You will need an originalAEG activated carbon filter for th...

Page 6: ... the filter flashing indicator D Indicates speed 2 LED and indication of the active carbon saturation for the filter flashing indicator E Indicates speed 3 F Indicates Intensive speed LED G Intensive speed on off The Intensive speed runs for 5 minutes If the hood is on when the Intensive speed is activated the hood revert to previous speed after 5 minutes If the hood is off when the Intensive spee...

Page 7: ...after the LED indicator for the active carbon filter D will activate at this point the saturation detection has been enabled To switch off the saturation detection depress and hold the A and B buttons for 3 seconds until the LED indicator for the active carbon filter is flashing Led Indicator for grease filter C The LED indicator for the grease filter will flash when it requires cleaning Follow th...

Page 8: ...ract the grease filter Fig 3 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when it are dry Dishwasher machine Place grease filters in dish washer Select most powerful washing programme and highest temperature at least 65 C Repeat the process Refit the...

Page 9: ...n the filter and later causes bad odours To reactivate the carbon the filter should be dried in an oven for 10 minutes with a temperature of maximum 100º C After approximately three years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Mounting Fit the carbon filter first rearward on the long supporting tongue then rotate it to close the motor...

Page 10: ...tor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Changing the light bulb Disconnect the cooker hood from the main supply Remove the lamp cover use a screw driver as a lever Fig 5 Replace the old bulb with a new one of the same type Remount the lamp cover If the light does not come on make sure the bulb has been inserted in correctly ...

Page 11: ...e to do so will cause grease deposits to build up that could constitute a fire hazard Special accessories Carbon filter Type 150 LONG LIFE Technical assistance service You are welcome to telephone our technical assistance service see list of technical assistance centres whenever you need information or in the unlikely event of a fault When calling please be ready to specify 1 The model code number...

Page 12: ...sed agent AEG reserves the right to stipulate the place of the repair i e the customer s home place of installation or AEG workshop 4 The guarantee or free replacement includes both labour and materials 5 Repairs carried out under guarantee do not extend the guarantee period for the appliance Parts removed during guarantee repairs become the property of AEG 6 The purchaser s statutory rights are n...

Page 13: ... of your new home They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances France Senlis 33 0 44 62 29 29 Germany Nürnberg 49 0 911 323 2600 Italy Pordenone 39 0 1678 47053 Sweden Stockholm 46 0 8 738 7910 UK Slough 44 0 1753 219899 ...

Page 14: ...Height x Width x Depht 81 136 x 89 8 x 51 Maximum absorbed power 215 W Motor absorption 1 x 130 W Lighting 4 x 20W Lenght of the cable 150 cm Mounting accessories included 2 hooks 1 chimney support 6 wall plugs Ø 8 mm 6 wood screws 5 x 45 mm 2 metal screws 2 9 x 13 4 metal screws 3 x 9 1 deflector 1 reduction flange 150 125 mm ...

Page 15: ...y be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided This disconnector may be for example a switch fuses plug fuses must be removed from the fuse box fault current switches and remote switches with a distance of over 3 mm between contacts The manufacture declines all r...

Page 16: ...the screws 11 Be careful that it is centered over the hood and horizontally aligned Fitting for extractor version S Connect a tube between the hood air outlet and the wall or roof exhaust channel Note that the top part of the chimney can be mounted with the side grids up or down For use as an extractor version hood it must be mounted with the grids downwards Fitting for filter version K Mount the ...

Page 17: ...66 Fig 6 K S S K Electric hob 600 mm Gas hob 700 mm Charcoal and oil 800 mm ...

Page 18: ...67 Exhaust tube Ø 150mm Power outlet Wall bracket Electric hob 600 mm Gas hob 700 mm Charcoal and oil 800 mm Electric hob 600 mm Gas hob 700 mm Charcoal and oil 800 mm ...

Page 19: ...rld s No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world ...