ADWA AD331 User Manual Download Page 2

Dear Customer,

Thank you for choosing an Adwa product.
Please read carefully this manual before starting operations.
This instrument is in compliance with the EMC Directive 89/
336/EEC and Low Voltage Directive 73/23/EEC for electrical
equipments.
For additional technical information, please e-mail us at
[email protected].

WARRANTY

Adwa warrants this product to be free of defects in material
and workmanship as stated in the operating manual. If repair
or adjustment is necessary and has not  been the result of
abuse, misuse or improper handling  within the warranty pe-
riod, please contact your dealer or the nearest Adwa Office for
the RGA (Return  Goods  Authorization) number  to put on the
outside of your  package. Warranted service will be made  with-
out charge. The meter is warranted for a period of 3 years,
while probes are warranted for 6 months.
 The warranty pe-
riod commences from the original date of sale. Warranty is
only valid when the product is used under normal conditions
and  in accordance with the instruction manual. The warranty
is void if the instrument is repaired or serviced by  unautho-
rized  personnel, not used in accordance to the instructions,
or  if  non-Adwa accessories such as buffer solutions, probes,
etc. are used in  conjunction with the meter. Adwa will not be
held  responsible for any accident whether directly or indi-
rectly, caused by the use of this instrument.

39

PROBES AND SOLUTIONS

AD3005D/1

Conductivity probe with built-in tem-
perature sensor, DIN connector and 1 m
cable

AD6020B

1413 µS/cm standard solution, 20 ml sa-
chet, 25 pcs

AD6020-100 1413 µS/cm standard solution, 100 ml

bottle

AD6021-100 12.88 mS/cm standard solution, 100 ml

bottle

AD6022-100 111.8 mS/cm standard solution, 100 ml

bottle

AD6031-100 800 ppm (mg/l) standard solution, 100

ml bottle

AD6032-100 6.44 ppt (g/l) standard solution, 100 ml

bottle

AD6033-100 40 ppt (g/l) / 80.0 mS/cm standard solu-

tion, 100 ml bottle

AD6040B

1500 ppm (mg/l) standard solution, 20
ml sachet, 25 pcs

AD9551           Serial communication cable

Summary of Contents for AD331

Page 1: ...332 Waterproof Portable Meters for EC and TDS Measurements w w w a d w a i n s t r u m e n t s c o m MANAD331R2 05 09 ADWA HUNGARY Kft Als kik t sor 11 6726 Szeged Hungary Tel 3662317878 Fax 366255061...

Page 2: ...l date of sale Warranty is only valid when the product is used under normal conditions and in accordance with the instruction manual The warranty is void if the instrument is repaired or serviced by u...

Page 3: ...only 34 PC interface AD332 only 36 Battery Replacement 37 Probe Maintenance 38 Probes and Solutions 39 TABLE OF CONTENTS 38 PROBE MAINTENANCE After measurements rinse the probe with clean water If a m...

Page 4: ...e setup procedure 4 AD331 AD431 and AD332 are waterproof portable meters AD331 reads EC in 5 ranges AD431 provides TDS readings in 5 ranges and AD332 can measure both EC and TDS All models also read t...

Page 5: ...the following information for EC or TDS LOG Record No 001 Date 2000 01 01 Time 00 19 EC 83 2 mS C 25 0 PC INTERFACE AD332 only Data transmission from the instrument to the PC can be done with the ADSW...

Page 6: ...ration Offset 0 0 ppm AD431 only Slope 1 point with 4 memorized standards 800 1382 ppm 6 44 40 0 ppt or one custom value 35 When in GLP mode the printout pro vides the following information When in SE...

Page 7: ...ed Environment 0 to 50 C RH max 95 Dimensions 188 x 96 x 70 mm Weight 460 g 34 PRINTING AD332 only When connected to an external serial printer a com plete set of information can be printed Use the AD...

Page 8: ...ble the Auto and H tags stop blinking and the read ing is frozen Press the HOLD key again to return to normal mea surement mode 8 FRONT AND TOP PANELS 33 Press CFM to confirm deletion or SHIFT HOLD ag...

Page 9: ...CL key to store the measured data and to recall stored data 4 CAL SETUPkey to enter exit calibration and setup mode 5 CFM key to confirm values 6 SHIFT key to activate the key alternate function Press...

Page 10: ...ading is displayed the meter shows the reading of next sample To return to measurement mode press SHIFT MRCL at any time 10 The meter is supplied complete with four 1 5 V AA alkaline batteries Remove...

Page 11: ...can be disabled through the AoFF setup item see Setup section for details VIEWING STORED DATA To retrieve memorized information press SHIFT and then MRCL keys The primary LCD displays the date day mo...

Page 12: ...D shows the temperature reading To store current reading into memory press STORE key from measurement mode The LCD will display for a few seconds the Stor mes sage together with the Log tag and the sa...

Page 13: ...h deion ized water before immersing it into the next sample For AD332 the TDS reading is obtained by mul tiplying the EC value by the TDS factor de fault 0 50 This factor can be selected by the user 0...

Page 14: ...ution By pressing SHIFT and lock keys the autoranging feature is disabled and the current range is frozen on the LCD The S mS ppm or ppt tag depend ing on the selected measurement mode and range start...

Page 15: ...compensation setting can be ac cessed through the tcE setup item see Setup section for details If the temperature compensation is active mea surements are compensated using the tempera ture coefficie...

Page 16: ...he new coefficient can be calculated with the following formula 1 20 If 1 90 C then 2 10 C For AD332 always set reference tempera ture to 25 C when measuring TDS 25 The following table lists the setup...

Page 17: ...olution The sleeve holes must be completely submerged Tap the probe repeatedly to remove any air bubbles that may be trapped inside the sleeve To enter calibration mode press the CAL key from the corr...

Page 18: ...tup item The cur rent value of the selected item starts blinking if the pa rameter can be modified For zero calibration simply leave the dry probe in the air The CAL and BUFFER tags light up The prima...

Page 19: ...select the proper EC or TDS range Press first CAL to enter the calibration mode and then RANGE or NEXT to enter the custom calibration Temperature reading can be manually fine tuned as ex plained in...

Page 20: ...the value displayed on the secondary LCD When the reading is stable the CFM tag starts blink ing Press CFM to confirm calibration 20 21 The instrument displays the Stor Good message and returns to me...

Reviews: