ADWA AD 310 User Manual Download Page 2

Dear Customer,
Thank you for choosing an Adwa product. Please read carefully
this manual before starting operations.

 

This instrument is in

compliance with the EMC directive 2004/108/EC and its
standards, and Low Voltage Directive 2006/95/EC and its
standards for electrical equipments.
For additional technical information, please e-mail us at

[email protected]

.

WARRANTY

Adwa warrants this product to be free of defects in material
and workmanship as stated in the operating manual. If repair
or adjustment is necessary and has not been the result of
abuse, misuse or improper handling within the warranty
period, please contact your dealer or nearest Adwa Office for
the RGA (Return Goods Authorization) number to put on the
outside of your package. Warranted service will be made without
charge. 

The meter is warranted for a period of three years,

while probes are warranted for six months.

 The warranty

period commences from the original date of sale. Warranty is
only valid when the product is used under normal conditions
and in accordance with the instruction manual. The warranty is
void if the instrument is repaired or serviced by unauthorized
personnel, not used in accordance to the instructions, or if
non-Adwa accessories such as buffer solutions, probes, etc.
are used in conjunction with the meter. Adwa will not be held
responsible for any accident whether directly or indirectly,
caused by the use of this instrument.

27

PROBES AND SOLUTIONS

AD76309

Conductivity probe with built-in temperature
sensor, DIN connector, 1 m cable

AD70031P

1413 

μ

S/cm EC standard solution, 20 ml

sachet, 25 pcs.

AD70030P

12.88 mS/cm EC standard solution, 20 ml
sachet, 25 pcs.

AD70032P

1382 ppm TDS standard solution, 20 ml
sachet, 25 pcs.

AD7030

 

12.88 mS/cm EC standard solution, 230 ml

AD7031

1413

 

μ

S/cm EC

 

standard

 

solution,

 

230 ml

AD7032

1382 ppm TDS standard solution, 230 ml

AD7033

 84 

μ

S/cm EC standard solution, 230 ml

AD7039

5000 

μ

S/cm EC standard solution, 230 ml

AD7034

80.00 mS/cm EC standard solution, 230

ml

AD7035

111.80 mS/cm EC standard solution, 230

ml

Summary of Contents for AD 310

Page 1: ...EC TDS and Temperature w w w a d w a i n s t r u m e n t s c o m ADWA INSTRUMENTSKft Als kik t sor 11 6726 Szeged Hungary Tel 3662317878 Fax 3662550610 e mail sales adwainstruments com www adwainstru...

Page 2: ...mmences from the original date of sale Warranty is only valid when the product is used under normal conditions and in accordance with the instruction manual The warranty is void if the instrument is r...

Page 3: ...ent 25 Probe Maintenance 26 Probes and Solutions 27 TABLE OF CONTENTS 26 PROBE MAINTENANCE After measurements rinse the probe with clean water If a more thorough cleaning is required remove the probe...

Page 4: ...ser selectable The instruments also feature a measurement stability indicator 25 BATTERY REPLACEMENT When batteries become weak the battery symbol lights up It is recommended to replace the batteries...

Page 5: ...ation solution 20 ml sachet each 1413 S cm for AD310 1382 ppm for AD410 Batteries 4 x 1 5V AA alkaline Instruction manual 24 To freeze the reading on the LCD press the HOLD key from measurement mode T...

Page 6: ...ne custom value TDS Calibration Offset 0 0 ppm AD410 Slope 1 point with 4 memorized standards 800 1382 ppm 6 44 40 0 ppt or one custom value 23 Note Press SHIFT and then SETUP key before confirmation...

Page 7: ...vironment 0 to 50 C RH max 95 Dimensions 70 x 145 x 26 mm Weight Approx 200 g 22 SETUP Setup mode allows to view and modify the instrument parameters To enter setup mode press SHIFT and then SETUP key...

Page 8: ...laythefactorydefaulttemperature Adjust the temperature reading on the LCD using the arrow keys The maximum allowed adjustment is 1 0 C around current reading Press SHIFT and CFM keys to confirm The me...

Page 9: ...tivate the key alternate function press and hold first the SHIFT key and then the second desired key 8 Liquid Crystal Display LCD 20 When the reading is stable the hourglass tag stops blinking Press S...

Page 10: ...or a few seconds then the LCD displays the not calibrated temperature compensated EC or TDS reading Pressing SHIFT and RANGE keys the LCD will show the temperature compensated EC or TDS reading factor...

Page 11: ...theair Notes If temperature is out of range the buF message and the C tag blink on the LCD If the reading is too far from the expected value buF message blinks For best results calibrate using a stand...

Page 12: ...rature reading in the selected range Notes If the meter displays only dashes the reading is out of range Ifthestabilityindicator hourglasssymbol blinks the reading is not stable 17 If necessary use th...

Page 13: ...t samples for accurate reading it is recommended to rinse the probe thoroughly with deionized water before immersing it into the sample 16 CALIBRATION STANDARD CALIBRATION EC AD310 or TDS AD410 calibr...

Page 14: ...ompensation setting can be accessed by entering the setup mode and selecting the tcE item see Setup section for details 15 If the temperature compensation is active measurements are compensated using...

Reviews: