Turning off the device
To turn off the unit, simply turn the control
knob to the "OFF" position
Display of specific messages
The device is completely secure. It carries out a permanent control of the temperature values and
several other electrical parameters in order to guarantee the user the best level of performance
and safety at all times.
If during use, a non
-
compliant operating state is detected, there may be a forced shutdown of the
device with the indication on the display of a flashing error code "Fx" or "Hx".
The different codes managed by the device are listed in the table below.
The code error flashing is effective as long as the user doesn
’
t stop the device manually
unplug and replug the unit, and then relaunch the device using the
«
On/Off
»
touch.
If a code error becomes permanent without having the possibility of cancelling it by
trying to relaunch the device, it is advised to get in touch with the after
-
sales service
specified by the retailer of the product.
ERROR CODE ON
DISPLAY
ERROR DESIGNATION
F1
Sensor vitro T°, short circuit or open circuit
F2
Sensor electronic T°, short circuit or open circuit
F3
3 phases line voltages out of range
F4
Power supplies out of ranges
F5
Sensor ambient T°, (inside the product), short circuit or open circuit
F6
Error with the control of the electronics components
F7
CONTROL board SOFTWARE unconformity
F8
Fans connection problems (fans absence or polarity inv with
-
)
H1 ou H3
Overheating under the vitro
H2 ou H4
Overheating of the power electronics components
H5
Problem with the vitro T° sensor under the vitro
H6
Overheating of the ambient temperature
EN
FR
ES
IMPORTANT
: The XL idncution cooking module is designed to operate only with a large cook-
ware. The XL utensil must be able to cover the 4 coils positioned under the glass ceramic of the
product.
The utensil must have a bottom diameter of at least 500mm.
ADVENTYS does not allow several smaller utensils to be used at the same time on the glass ce-
ramic, even if they are detected and allow power to be sent.
The magnetic radiation emitted by an inducteyr which would not be covered correctly could gene-
rate a radiated emission above the limits authorized by the standards in rigor.