8.
–
Troubleshooting
8.1 - LED Codes
Please refer to the table below for condition codes for the onboard status and power LEDs.
POWER LED (GREEN)
STATUS LED (RED)
CONDITION
SOLID
SLOW FLASHING
NORMAL OPERATION, MAIN
APPLICATION RUNNING OK
SOLID
SOLID
MAIN APPLICATION NOT
RUNNING
SOLID
OFF
MAIN APPLICATION NOT
RUNNING
OFF
SOLID
MAIN APPLICATION NOT
RUNNING
ALTERNATE FLASHING
ALTERNATE FLASHING
BOOTLOADER MODE
OFF
OFF
NO POWER
Table 2
Please refer to the table below for condition codes for the Ethernet jack status LEDs.
LINK LED (GREEN)
DATA LED (YELLOW)
CONDITION
SOLID
RAPID FLASHING
CONNECTED OK, RECEIVING
DATA
SOLID
OFF
CONNECTED OK, NO DATA
DATA
OFF
OFF
NO LINK ESTABLISHED OR
POWER IS OFF
Table 3
8.2 - No Status/Power LEDs On
Ensure that your power supply is supplying correct voltage as per section 3.1. Also ensure that it can
supply enough power to drive the lights that are connected as well. You should also try
disconnecting all outputs and see if the controller starts then. If the supplied power is correct try
performing a forced firmware update as per section 6.4.