BB-ZP9D115RMLR-A Radio Modem
23
COMMAND DESCRIPTIONS
•
Commands in this section are listed alphabetically.
•
Command categories are designated between the "< >" symbols that follow each
command title.
•
By default, the Zlinx Radio Modem expects numerical values in hexadecimal since the
default value of the CF (Number Base) Parameter is '1'.
•
Hexadecimal values are designated by the "0x" prefix and decimal values by the "d"
suffix.
%V (Board Voltage) Command
<Diagnostics> %V Command is
used to read the current voltage of
the module circuit board.
Sample Output:
5.02 V (when ATCF = 0)
5051F (when ATCF = 1) *
5.02 (when ATCF = 2)
* When CF = 1 (default), a hex integer is shown that is equal to (voltage * 65536d).
AM (Auto-set MY) Command
<Networking & Security> AM
Command is used to automatically
set the MY (Source Address)
parameter from the factory-set serial number of the module. The address is formed with
bits 29, 28 and 13-0 of the serial number (in that order). The resulting value is displayed as
a result of this command.
AP (API Enable) Command
<Serial Interfacing> The AP command is
used to enable the module to operate
using the frame-based API operation.
AT Command: AT%V
Binary Command: 0x3B (59 decimal)
Parameter Range (read-only):
0x2CCCA - 0x5BFFA (2.80 - 5.75 decimal)
Number of Bytes Returned: 4
AT Command: ATAM
Binary Command: 0x40 (64 decimal)
AT Command: ATAP
Parameter Range: 0 - 2
Parameter
Configuration
0
API Disabled
(Transparent
Operation)
1
API Enabled (w/out
escaped characters)
2
API Enabled (with
escaped characters)
Default Parameter Value: 0
Number of Bytes Returned: 1
Minimum Firmware Version Required: 2x20