If the entrance width is greater than 3.2m, more than one device are required. Follow the steps 

of installing single device to install each device while paying special attention to the following.

Multiple Devices

Each device shall keep the same distance 

from the door. As shown in the photo, three 

devices keep the same 60cm distance from the 

door.

Plan the distances between devices and their 

distances from the wall before installation.

Entrance width: 6m

Quantity of devices:  2

Distance from the wall: 

A: 1.5m; B: 1.5m from the other wall.

A

B

Switch

POE Injector

UCAM-120

UCAM-120

Switch

POE Switch

Connect devices based on site situation and quantity of devices using either of three optional 

networking structures.

For further information, please send to [email protected]

Constant red 

light indicates 

device error.

Constant orange light 

indicates default factory 

settings; flashing light 

indicates server connecting 

error.

Flashing green light 

indicates device 

connected to server, 

working normally.