55
www.advantech.com
Figure 6.10
1. Off Event Delay
: You may set how many seconds you want system auto shut
down after ignition off.
2. On
Delay:
You may set how many seconds you want the system to auto power
on.
3. Low
Delay:
When the battery voltage is below certain value you set, it will
automatically shut down to prevent the system will consume the battery.
6.3.4
TREK-550 power consumption
OS: Windows Embedded Standard
Burn-in test V6.0
Idle Mode
100% Burn-in Test Mode
Off mode (S5)
w/o TREK-303H
12V / 1.04A
12V / 1.20A
w/ TREK-303H
12V / 1.51A
12V / 1.94A
12V / 1.75mA
*Doesn’t support S1, S3, S4
6.4
GPIO Test
1. Execute I/O Test, connect GPIO loopback, click Pin0
ĺ
Set, the end which Read
the signal, the bulb will be light up, like wise to Pin1~Pin3. Next pick Digital output
to execute the same procedure. See
figure 6.
Figure 6.15
Summary of Contents for TREK-550
Page 1: ...User Manual TREK 550 Computing Box ...
Page 20: ... ...
Page 36: ...5 9 LED indicator TREK 550 User Manual 22 ...
Page 48: ...53 www advantech com Figure 6 9 Read the value D Set the value ...
Page 55: ...60 www advantech com TREK 303 Specification TREK 303 demo SW application program Figure 6 17 ...
Page 57: ......
Page 58: ...TREK TREKͲ Dipol Comb K 550 A2 30 bo Antenna 3 User 4 44 ...