Note:
Q1
: How is the low-battery event raised or canceled?
A1
: The minimum value on LOW_DELAY parameter is 1 second. If the voltage remains lower
than the LOW_THRESHOLD in the duration of LOW_DELAY, the low-battery event will be
raised and immediately send a power button press signal to OS.
During the duration of LOW_DELAY, if the battery voltage is back to be higher than
LOW_THRESHOLD, the LOW_DELAY will be reset to predetermined value and stop count
down.
Therefore, the LOW_DELAY parameter acts as a filter to prevent incorrect low-battery-event
from happening.
6.3.2
Power Management demo program
A. Check the files.
Make sure that there are two components include in TREK-550 Power Management Tool. One
is “AdvXP_CAN.dll”, another one is “TREK-550 Power Manager.exe”.
B. Start up the program
Execute Power Management tool and you will see a message box shows “Connect OK”.
Then Click OK button and you will see the main page as below.
6.3.3
Power Management Parameter settings
The parameters for power management on TREK-550 could be set by Demo program (see the
image below) or SDK/API.
TREK-550 User Manual
22