4.3.3
Power Management Parameter settings
The parameters for power management on TREK-520 could be set by Demo program
(see the image below) or SDK/API.
Figure 4.9 power management demo utility
Figure 4.9 Off event delay
Off Event Delay
– it means after 5 seconds delay from receiving of ignition OFF signal,
EC controller will send a shutdown event to make system start shutdown process
Figure 4.9 Hard Off delay
Hard off Delay
– it means after 30 seconds from shutdown event, EC controller will
force power cut off at the same time.
31
www.advantech.com