SmartStart SL305
Binary Input
Logical 0 / 1
∗
Voltage
Web interface status
logic 0
0 – 0.7 V
On
logic 1
1.6 – 36 V
Off
Table 7: Characteristics of binary input
∗
The binary input status in the Shell is returned via
io get bin0
.
Binary Output
The binary output is open in the default configuration. The current of the binary output is
limited by a resettable fuse (200 mA).
Binary inputs and output connections
Binary inputs and output connections example:
Figure 17: Binary connection
Low Power Mode
The router can be put into low power mode using a special command
lpm
. It can then be
awakened by an activity on binary input or using an internal timer. For more details of this
command, see the application note
Commands and Scripts
. Consumption in LPM mode
may vary depending on the configuration of the router.
All metal parts are connected together with the negative pole of power supply (common pole).
However, the router box may not be connected to the negative pole properly.