System power on
A 2-pin power connector is included in the accessory box. Connect the power con
-
nector to 12-30VDC power lines and plug the power lines into the system power
receptor. DC power source shall be complied with ES1 requirements, output rating is
12-30Vdc, 8-4A, with minimum operating temperature 50°C, and has to be evaluated
according to IEC/UL 60950-1 and/or IEC/UL 62368-1.
Figure 2.17 Terminal block
The terminal block is suitable for 16 AWG min. Torque value 4.5 lb-in min. User cop
-
per conductors only. Must be installed by skilled person.