4 4
PCLS-848-P User's Manual
Mnemonic
UNL
UNT
GET
DCL
GTL
PPC
PPD
PPU
ASCII
?
(Hex)
(3F)
(SF)
(08)
(14)
(01)
(05)
(70)
(15)
Mnemonic
SDC
SPD
SPE
TCT
*MLA
*MTA
LLO
ASCII
5
U
(uex)
(04)
(19)
(18)
(09)
(35)
(55)
(11)
* My addrese = 21 (15P)
The following commands take some actions other than sending characters.
LISTEN
Take following values as listener address.
TALK
Take following values as talker address.
DATA
Set ATN false.
EOI
Set EOI true at last data byte.
PPE
Take following values as Parallel Poll Config.
IFC
Pulse IFC true for 100 microseconds.
CMD
Set ATN true.
SEC
Take following values as secondary commands.
Summary of Contents for PCLS-848-P
Page 1: ...PCLS 848 P IEEE 488 INTERFACE CARD PASCA SUPPORT PACKAGE USER S MANUAL...
Page 6: ...Figures Figuree 7 1 PCL 848A B Block Diagram 77...
Page 10: ...4 PCLS 848 P User s Manual...
Page 20: ...14 PCLS 848 P User s Manual...
Page 32: ...26 PCLS 848 P User s Manual If addr 0 or addr 30 ATN is set false String is entered...
Page 37: ...CHAPTER 2 INSTALLATION 31 ieinit ioport myaddr setting...
Page 42: ...36 PCLS 848 P User s Manual If addr 0 or addr 30 ATN is set false Long string is sent...
Page 56: ...50 PCLS 848 P User s Manual...
Page 80: ...74 PCLS 848 P User s Manual...
Page 83: ...CHAPTER 7 THEORY OF OPERATION 77 Figuree 7 1 PCL 848A B Block Diagram...
Page 84: ...78 PCLS 848 P User s Manual...
Page 95: ...CHAPTER 7 THEORY OF OPERATION 89...
Page 97: ...CHAPTER 7 THEORY OF OPERATION 91 Handshake Timing Sequence...
Page 102: ...96 PCLS 848 P User s Manual...