PCLS-848-P User's Manual
3.4.4. ieenter
NAME:
ieenter
—
Enters a string from a device or the interface
SYNTAX:
ieenter(addr,instr);
addr:integer;
Device address. If 0<=addr<=30, then it enters the string from
the specified device. Otherwise, it enters the string from the
interface.
instr: Istring;
The data string entered.
DESCRIPTION:
This procedure enters a string from a device or from the interface. Reading is
terminated upon receiving the terminator specified by the EOL command or the
maximum length of data bytes is reached.
BUS ACTIVITY:
- If 0 <= addr <= 30
ATN is set true.
REN is set true.
UNL is sent.
TAD is sent.
MLA is set.
ATN is set false.
Data string is entered.
- If addr < 0 or addr > 30
ATN is set false.
Data string is entered.
REMARK:
The length of the string entered can be checked by iestatUs( ).
Summary of Contents for PCLS-848-P
Page 1: ...PCLS 848 P IEEE 488 INTERFACE CARD PASCA SUPPORT PACKAGE USER S MANUAL...
Page 6: ...Figures Figuree 7 1 PCL 848A B Block Diagram 77...
Page 10: ...4 PCLS 848 P User s Manual...
Page 20: ...14 PCLS 848 P User s Manual...
Page 32: ...26 PCLS 848 P User s Manual If addr 0 or addr 30 ATN is set false String is entered...
Page 37: ...CHAPTER 2 INSTALLATION 31 ieinit ioport myaddr setting...
Page 42: ...36 PCLS 848 P User s Manual If addr 0 or addr 30 ATN is set false Long string is sent...
Page 56: ...50 PCLS 848 P User s Manual...
Page 80: ...74 PCLS 848 P User s Manual...
Page 83: ...CHAPTER 7 THEORY OF OPERATION 77 Figuree 7 1 PCL 848A B Block Diagram...
Page 84: ...78 PCLS 848 P User s Manual...
Page 95: ...CHAPTER 7 THEORY OF OPERATION 89...
Page 97: ...CHAPTER 7 THEORY OF OPERATION 91 Handshake Timing Sequence...
Page 102: ...96 PCLS 848 P User s Manual...