NYS-3510/NYS-3520 User Manual
44
Setting Items:
iOSD
combo box: Select a Modbus controlling setting. There are two options:
iOsd1 and iOsd2.
Enable
check box: Check this box to enable this set of Modbus controlling. Use
Mouse to click on the video preview window for assigning the location of the
reading. The assigned location will be marked with a red cross.
Position X and Position Y
: Report the coordinate of location which shows the
reading.
Set
button: Click this button to accept the assigned location.
Protocol
combo box: Select a Modbus protocol.
–
Options: Modbus_RTU-Master, Modbus_TCP-Server.
Memory Type
: Current memory type is 4X only.
Addres
s combo box: Address has four options 1, 2, 3 and 4.
K radio
box: The K parameter in transfer formula of reading value.
–
Formula: Output_Value = (K x Input_Value) + Bias
Bias
box: The Bias parameter in transfer formula of reading value.
Display Format
: Assign the format of output value.
–
Total Digits
combo box: Assign how many digits to display (not include
point).
–
Fractional Digits
combo box: Assign how many digits after the decimal point
to display.
–
Font Color
combo box: Select the color of output text. Options: White and
Black.
–
Tag Name
box: Assign the tag of the output value. Only accept capital and
number.
Note!
The sum of total characters of Digits and Tag Name is 14.
Summary of Contents for NVS-3510
Page 1: ...User Manual NVS 3510 NVS 3520 IP Video Server ...
Page 7: ...Chapter 1 1 Overview Introduction Features Specifications Packing List Chassis Introduction ...
Page 16: ...NYS 3510 NYS 3520 User Manual 10 ...
Page 17: ...Chapter 2 2 Installation System Requirement Hardware Installation Software Installation ...
Page 22: ...NYS 3510 NYS 3520 User Manual 16 ...
Page 23: ...Chapter 3 3 Startup Startup First Page Live View ...
Page 53: ...Chapter 5 5 Utility Using eSearch Restore to Factory Default ...
Page 57: ...51 NYS 3510 NYS 3520 User Manual Chapter 5 Utility ...