background image

27

MIO-5377 User Manual

C

ha

pte

r 3
Ju

m

pe

rs 

an

d C

on

ne

cto

rs

27

GND

28

NC

29

NC

30

M2B1_UIM_RESET

31

NC

32

M2B1_UIM_CLK

33

GND

34

M2B1_UIM_DATA

35

NC

36

M2B1_UIM_PWR

37

NC

38

NC

39

GND

40

NC

41

M2B1_PCIE_RX-

42

NC

43

M2B1_

44

NC

45

GND

46

NC

47

M2B1_PCIE_TX-

48

NC

49

M2B1_

50

M2B1_PERST#

51

GND

52

M2B1_a_CLKREQ#

53

CLK100M_a_M2B1-

54

M2B1_PCIEWAKE#

55

CLK100M

56

NC

57

GND

58

NC

59

NC

60

NC

61

NC

62

NC

63

NC

64

NC

65

NC

66

NC

67

M2B1_a_RESET#

68

M2B1_SUSCLK

69

M2_SATA1B_PEDET

70

+V3.3A_M.2_B

71

GND

72

+V3.3A_M.2_B

73

GND

Table 3.23: M.2 Key-B Connector: M2_B1

Summary of Contents for MIO-5377

Page 1: ...User Manual MIO 5377 12th Gen Intel Core i7 i5 i3 Celeron Series 3 5 SBC ...

Page 2: ...ponsibility for its use nor for any infringe ments of the rights of third parties that may result from its use Acknowledgments Intel is a trademark of Intel Corporation AMI is a trademark of American Megatrends Inc IBM PC PS 2 and VGA are trademarks of International Business Machines Corpo ration Microsoft Windows DirectX is a registered trademark of Microsoft Corp All other product names or trade...

Page 3: ...cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any on screen messages you get when the problem occurs 2 Call you...

Page 4: ... and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FM This equipment ha...

Page 5: ...A Power Cable 35 cm p n 1700031583 01 1 x USB 2 0 Cable 20 cm p n 1700030406 01 1 x Audio Cable 20 cm p n 1700019584 01 2 x COM RS 232 422 485 Cable 20 cm p n 1700030404 01 2 x COM RS 232 Cable 20 cm p n 1700031582 01 1 x Cooler Heatsink p n 1970005512T001 1970005548T001 1 x Startup manual p n 2046537700 1 x Screw kit 3 x screws for M 2 device 4 x screws and stand off for Heatsink Cooler 1 x Devic...

Page 6: ...MIO 5377 User Manual vi ...

Page 7: ...fault J1 10 3 2 Connectors 11 3 3 Locating Connectors 12 3 4 Setting Jumpers 13 Table 3 3 CANBus Internal Connector CN3 13 Table 3 4 CANBus Internal Connector CN2 13 Table 3 5 I2C Internal Connector CN8 14 Table 3 6 I2C Internal Connector CN7 14 Table 3 7 I2C Internal Connector CN6 14 Table 3 8 Panel Inverter Connector BL1 15 Table 3 9 Smart FAN Internal Connector FAN 15 Table 3 10 LVDS Connector ...

Page 8: ...Main Setup 30 4 1 2 Advanced BIOS Features Setup 31 4 1 3 Chipset Configuration 52 4 1 4 Security 62 4 1 5 Boot 63 4 1 6 Save Exit 64 Appendix A 65 A 1 System I O Ports 66 A 2 DMA Channel Assignments 67 A 3 1st MB Memory Map 67 A 4 Interrupt Assignments 67 ...

Page 9: ...Chapter 1 1 General Information ...

Page 10: ... 15W 15W 15W Chipset On package Intel 600 Series Chipset BIOS AMI EFI 256Mbit Memory Technology DDR5 4800 Max Capacity Up to 64GB Channel Socket Dual Channels 2 Sockets Graphics Controller Intel Iris Xe Graphics Max Frequency 1 35GHz 1 25GHz 1 2GHz 1 1GHz 1 1GHz Execution Unit 96 96 80 64 48 3D HW Acceleration DX12 OGL4 0 OCL1 2 HW Encode H 265 HEVC H 264 MPEG2 HW Decode H 265 Display I F LCD 1 x ...

Page 11: ...65536 level 0 65535 sec TPM TPM2 0 iManager 3 0 SW API for Hardware Monitor Smart Fan Control Brightness Control I2C GPIO WDT Expansion M 2 E Key 1 x E Key 2230 PCIex1 USB2 0 M 2 B Key 1 x B Key 3042 LTE 3052 5G w Nano SIM B Key default 3042 length M 2 M Key 1 x M Key 2280 PCIex4 Gen 4 NVMe Power Supply Voltage Vin DC 12V 24V 10 RTC Battery Lithium 3V 210mAH Connector ATX 2x2 pin 90D optional DC J...

Page 12: ...226 PCIex1 SATA Gen 3 I2C CH 0 CH 1 eSPI HDMI2 0b USB4 TBT4 USB Type C USB3 2 DP TCP_2 DP1 4 DDI_B TCP_3 USB3 2 P2 P3 USB3 2 USB2 0 TCP_1 USB2 0 P0 P1 USB2 0 TPM 2 0 SPI EIO 201 Intel Alder Lake P i7 i5 i3 Celeron 15 28W DDR5 4800 Up to 32GB DDR5 4800 Up to 32GB Internal I O External I O PI3HDX1204B1ZHIEX Retimer SPI 256M BIOS COM1 RS 232 422 485 COM2 RS 232 422 485 COM3 RS 232 COM4 RS 232 CAN1 CA...

Page 13: ...Chapter 2 2 Mechanical Specifications ...

Page 14: ...hapter includes board dimension and assembly instructions for standard thermal solutions 2 2 Board Layout Dimensions Figure 2 1 MIO 5377 Mechanical Diagram Top Side Figure 2 2 MIO 5377 Mechanical Diagram Bottom Side 0 3 30 58 28 72 28 86 28 142 70 146 0 20 50 23 09 27 20 55 65 88 20 92 70 98 70 102 0 3 30 142 70 146 0 20 50 27 20 92 70 98 70 102 ...

Page 15: ... Figure 2 6 MIO 5377 Mechanical Diagram with Heatspreader 0 2 11 20 16 34 0 8 30 26 30 45 58 67 65 85 50 100 60 119 39 130 81 139 50 146 155 88 0 2 11 20 16 34 33 7 0 8 30 26 30 45 58 67 65 85 50 100 60 119 39 130 81 139 50 146 155 88 0 2 11 20 16 34 26 0 8 30 26 30 45 58 67 65 85 50 100 60 119 39 130 81 139 50 146 155 88 0 8 30 26 30 45 58 67 65 85 50 100 60 119 39 130 81 139 50 146 155 88 0 2 25...

Page 16: ...e box inside the package Please assemble it by following the diagram below Remember to remove the plastic from thermal pad before assembly Figure 2 7 MIO 5377 Cooler Installation Figure 2 8 MIO 5377 Heatsink Installation Figure 2 9 MIO 5377 Heatspreader Installation Remove release paper Remove release paper Remove release paper ...

Page 17: ...Chapter 3 3 Jumpers and Connectors ...

Page 18: ...nel Voltage 1 3 3 3V Default 3 5 5V 3 4 12V Table 3 2 AT mode Load BIOS default J1 Jumper Short Panel Functional 1 2 AT ATX MODE Selection 1 2 open ATX mode 1 2 short AT mode 3 4 NORMAL_BIOS Default 3 4 open Reserve 3 4 short Reserve 5 6 LOAD_BIOS_Default 5 6 open Noraml 5 6 short Load BIOS Default ...

Page 19: ...nverter Connector 18 FAN Smart FAN 19 J1 AT mode Load BIOS default 20 VDD1 Panel Voltage Selection Jumper 21 LVDS1 LVDS Connector 22 USB3 USB2 0 Internal Connector 23 AUDIO1 Audio Internal Connector 24 SATA1 SATA Connector 25 SATAP1 SATA Power Connector 26 TYPEC2 TypeC Port TBT4 27 COM1 COM Port Internal Connector 1 28 CN4 Front Panel Internal Connector 29 COM2 COM Port Internal Connector 2 30 CN5...

Page 20: ...MIO 5377 User Manual 12 3 3 Locating Connectors ...

Page 21: ...3 In this case you would connect either pins 1 and 2 or 2 and 3 The jumper settings are schematically depicted in this manual as follows A pair of needle nose pliers may be helpful when working with jumpers If you have any doubts about the best hardware configuration for your application contact your local distributor or sales representative before you make any changes Generally you simply need a ...

Page 22: ...AT 3 SOC_I2C1_z_CLK 4 V33_I2CCONN1 Table 3 6 I2C Internal Connector CN7 PN 1655904020 Vendor MPN Aces 85205 04001 Pin Signal Pin Definition 1 GND 2 SOC_I2C0_z_DAT 3 SOC_I2C0_z_CLK 4 V33_I2CCONN0 Table 3 7 I2C Internal Connector CN6 PN 1655904020 Vendor MPN Aces 85205 04001 Pin Signal Pin Definition 1 GND 2 EC_I2C0_z_DAT 3 EC_I2C0_z_CLK 4 V33_I2CCONN ...

Page 23: ...653007388 01 Vendor MPN Pinrex 721 81 05TWR0 Pin Signal Pin Definition 1 V12_1_INVERTER_0 2 GND 3 LVDS1_z_ENABKL 4 EC_LVDS1_z_PWM 5 V5_1_INVERTER_0 Table 3 9 Smart FAN Internal Connector FAN PN 1653008788 01 Vendor MPN Aces 50273 00401 001 Pin Signal Pin Definition 1 GND 2 V12 3 FAN_SPEED 4 FAN_V5_PWM ...

Page 24: ...D0 9 LVDS1_0_D0 10 LVDS1_1_D0 11 GND 12 GND 13 LVDS1_0_D1 14 LVDS1_1_D1 15 LVDS1_0_D1 16 LVDS1_1_D1 17 GND 18 GND 19 LVDS1_0_D2 20 LVDS1_1_D2 21 LVDS1_0_D2 22 LVDS1_1_D2 23 GND 24 GND 25 LVDS1_0_CLK 26 LVDS1_1_CLK 27 LVDS1_0_CLK 28 LVDS1_1_CLK 29 GND 30 GND 31 LVDS0_DDCCLK_AUX 32 LVDS0_DDCCLK_AUX 33 GND 34 GND 35 LVDS1_0_D3 36 LVDS1_1_D3 37 LVDS1_0_D3 38 LVDS1_1_D3 39 NC 40 LVDS1_VCON 41 NC 42 NC ...

Page 25: ...Signal Pin Definition 1 V5SB_USB_UTC 2 V5SB_USB_UTC 3 USB8_z_P 4 USB9_z_P 5 USB8_z_P 6 USB9_z_P 7 GND 8 GND 9 GND 10 NC Table 3 12 Audio Internal Connector AUDIO1 PN 1653008214 01 Vendor MPN Pinrex 52C 90 10GBE0 Pin Signal Pin Definition 1 LOUTR 2 LINR 3 AUD_CONN_GND 4 AUD_CONN_GND 5 LOUTL 6 LINL 7 AUD_CONN_GND 8 FRONT_JD 9 MIC1R 10 MIC1L Table 3 10 LVDS Connector LVDS1 ...

Page 26: ...r MPN Pinrex 721 81 02TW00 Pin Signal Pin Definition 1 V5SATA0 2 GND Table 3 14 COM Port Internal Connector 1 COM1 PN 1653007728 02 Vendor MPN Aces 50273 0107N 002 Pin Signal Pin Definition 1 NC 2 COM1_RI 3 COM1_DTR 4 COM1_CTS 5 COM1_TXD 6 COM1_RTS 7 COM1_RXD 8 COM1_DSR 9 COM1_DCD 10 GND ...

Page 27: ... Vendor MPN Aces 50273 0107N 002 Pin Signal Pin Definition 1 NC 2 COM2_RI 3 COM2_DTR 4 COM2_CTS 5 COM2_TXD 6 COM2_RTS 7 COM2_RXD 8 COM2_DSR 9 COM2_DCD 10 GND Table 3 16 COM Port Internal Connector 3 COM3 PN 1655004032 Vendor MPN Aces 85205 05701 Pin Signal Pin Definition 1 COM3_TXD 2 COM3_RTS 3 COM3_RXD 4 COM3_CTS 5 GND ...

Page 28: ...5205 05701 Pin Signal Pin Definition 1 COM4_TXD 2 COM4_RTS 3 COM4_RXD 4 COM4_CTS 5 GND Table 3 18 Front Panel Internal Connector CN4 PN 1653007728 02 Vendor MPN Aces 50273 0107N 002 Pin Signal Pin Definition 1 GND 2 BUZZER 3 BUZZER 4 RDC_CASEOPEN 5 SATA_HDD_LED 6 FP_a_PSIN 7 FP_a_RST 8 V3 3 9 NC 10 V5 ...

Page 29: ...r CN5 PN 1653007728 02 Vendor MPN Aces 50273 0107N 002 Pin Signal Pin Definition 1 GND 2 EC_P1_GPIO7 3 EC_P1_GPIO2 4 EC_P1_GPIO6 5 EC_P1_GPIO1 6 EC_P1_GPIO5 7 EC_P1_GPIO0 8 EC_P1_GPIO4 9 V5_P1_GPIO 10 EC_P1_GPIO3 Table 3 20 RTC battery Connector BAT1 Pin Signal Pin Definition 1 GND 2 VBAT_a1 ...

Page 30: ...22 Table 3 21 M 2 Key E Connector M2_1 Pin Signal Pin Definition 1 GND 2 V3 3SB_M 2_E 3 USB6_z_P 4 V3 3SB_M 2_E 5 USB6_z_P 6 NC 7 GND 8 NC 9 NC 10 NC 11 NC 12 NC 13 NC 14 NC 15 NC 16 NC 17 NC 18 GND 19 NC 20 NC 21 NC 22 NC ...

Page 31: ...43 PCIE_M2_RX11 44 NC 45 GND 46 NC 47 CLK_M2E_z_PCIE 48 NC 49 CLK_M2E_z_PCIE 50 SUSCLK_z_EKEY 51 GND 52 PLTRST_BUFFER 53 PCIE_a_CLKREQ2 54 BT_DISABLE 55 PCIE_WAKE 56 WIFI_DISABLE 57 GND 58 NC 59 NC 60 NC 61 NC 62 NC 63 GND 64 NC 65 NC 66 NC 67 NC 68 NC 69 GND 70 NC 71 NC 72 V3 3SB_M 2_E 73 NC 74 V3 3SB_M 2_E 75 GND H1 NC H2 NC Table 3 21 M 2 Key E Connector M2_1 ...

Page 32: ...Definition 1 GND 2 V3 3_M 2 3 GND 4 V3 3_M 2 5 PCIE4_KEY M_RX3 6 NC 7 PCIE4_KEY M_RX3 8 M 2_PLN 9 GND 10 NC 11 PCIE4_KEY M_a_TX3 12 V3 3_M 2 13 PCIE4_KEY M_a_TX3 14 V3 3_M 2 15 GND 16 V3 3_M 2 17 PCIE4_KEY M_RX2 18 V3 3_M 2 19 PCIE4_KEY M_RX2 20 NC 21 GND Table 3 21 M 2 Key E Connector M2_1 ...

Page 33: ...6 NC 37 PCIE4_KEY M_a_TX1 38 NC 39 GND 40 NC 41 PCIE4_KEY M_RX0 42 NC 43 PCIE4_KEY M_RX0 44 NC 45 GND 46 NC 47 PCIE4_KEY M_a_TX0 48 NC 49 PCIE4_KEY M_a_TX0 50 PLTRST_MKEY_BUFFER 51 GND 52 CLK2_M2MB_a_PCIE_REQ 53 CK_100M_a_MKEY_N 54 M 2_PCIE_WAKE 55 CK_100M_a_MKEY_P 56 NC 57 GND 58 NC 67 NC 68 PCH_SUSCLK_R_MKEY 69 NC 70 V3 3_M 2 71 GND 72 V3 3_M 2 73 GND 74 V3 3_M 2 75 GND H1 NC Table 3 22 M 2 Key ...

Page 34: ...finition 1 M2B1_CFG3 2 V3 3A_M 2_B 3 GND 4 V3 3A_M 2_B 5 GND 6 M2B1_FULL_CARD_OFF 7 USB_M2B1_P 8 M2B1_W_DISABLE1 9 USB_M2B1_N 10 M2B1_LED1 11 GND 20 M2B1_PCIE_DIS 21 M2B1_CFG0 22 M2B1_ANT_CFG 23 M2B1_WAKE_ON_WWAN 24 M2B1_ANT_TUNER 25 M2B1_DPR 26 M2B1_W_DISABLE2 Table 3 22 M 2 Key M Connector M2_2 ...

Page 35: ...NC 41 M2B1_PCIE_RX 42 NC 43 M2B1_PCIE_RX 44 NC 45 GND 46 NC 47 M2B1_PCIE_TX 48 NC 49 M2B1_PCIE_TX 50 M2B1_PERST 51 GND 52 M2B1_a_CLKREQ 53 CLK100M_a_M2B1 54 M2B1_PCIEWAKE 55 CLK100M_a_M2B1 56 NC 57 GND 58 NC 59 NC 60 NC 61 NC 62 NC 63 NC 64 NC 65 NC 66 NC 67 M2B1_a_RESET 68 M2B1_SUSCLK 69 M2_SATA1B_PEDET 70 V3 3A_M 2_B 71 GND 72 V3 3A_M 2_B 73 GND Table 3 23 M 2 Key B Connector M2_B1 ...

Page 36: ...MIO 5377 User Manual 28 74 V3 3A_M 2_B 75 M2B1_CFG2 H1 NC H2 NC H3 GND H4 GND Table 3 23 M 2 Key B Connector M2_B1 ...

Page 37: ...Chapter 4 4 AMI BIOS Setup ...

Page 38: ... check for the patch code If there is a number assigned to the patch code it means that the BIOS supports your CPU If there is no number assigned to the patch code please contact an Advantech application engineer to obtain an up to date patch code file This will ensure that your CPU s system status is valid After ensuring that you have a number assigned to the patch code press DEL and you will imm...

Page 39: ...ime or System Date using the Arrow keys Enter new values through the keyboard Press the Tab key or the Arrow keys to move between fields The date must be entered in MM DD YY format The time must be entered in HH MM SS format 4 1 2 Advanced BIOS Features Setup Select the Advanced tab from the MIO 5377 setup screen to enter the Advanced BIOS Setup screen You can select any of the items in the left f...

Page 40: ...es if Enabled to load PTID Table Native PCIE Enable Enable Disable PCIE Native Control reported in ACPI Table Native ASPM Choose ASPM feature is controlled by OS or BIOS BDAT ACPI Table Support Determines if Enabled to support BDAT ACPI Table Low Power S0 Idle Capability ...

Page 41: ...e Prefetch This item allows users to enable or disable the adjacent cache line prefetch fea ture Intel VMX Virtualization Technology When Enabled a VMM can utilize the additional hardware capability provided by Vanderpool Technology AVX Enable Disable the AVX 2 3 Instructions Active Performance cores Number of P cores to enable in each processor package Active Efficient cores Number of E cores to ...

Page 42: ...rdware capability provided by Intel Trusted Execution Technology Total Memory Encryption Configure Total Memory Encryption TME to protect DRAM data from physical attacks 4 1 2 3 Power Performance CPU Power Management Control CPU Power Management Control Options GT Power Management Control GT Power Management Control Options ...

Page 43: ...ft Technology support HDC Control Enable Disable Intel HDC Turbo Mode Enable Disable processor turbo mode View Configure Turbo Options View and Configure Turbo Options Config TDP Configuration Config TDP Configuraitons Platform PL1 Enable Enable Disable Platform Power Limit 1 programming Platform PL2 Enable Enable Disable Platform Power Limit 1 programming Power Limit 4 Override Enable Disable Pow...

Page 44: ...onfigure Turbo Ratio Limit Options Energy Efficient P state Enable Disable Energy Efficient P state feature Package Power Limit MSR Lock Enable Disable locking of Package Power Limit settings Energy Efficient Turbo Enable Disable Energy Efficient Turbo feature Config TDP Configurations ...

Page 45: ...cTDP or cTDP Configurable TDP Boot Mode Configurable TDP Mode as Nominal Up Down Deactivate TDP selection Configurable TDP Lock Configurable TDP Mode Lock sets the Lock bit CTDP BIOS control Enables CTDP control via runtime ACPI BIOS method Power Limit 3 Settings Power Limit 3 Override Enable Disable Power Limit 3 override ...

Page 46: ...er Standby Check to enable render standby support Maximum GT frequency Maximum GT frequency limited by user Disable Turbo GT frequency Enabled Disabled Turbo GT frequency 4 1 2 4 PCH FW Configuration ME State When Disabled ME will be put ME into Temporarily Disabled Mode ...

Page 47: ...ssage sent to ME Firmware Update Configuration Configure Management Engine Technology Parameters 4 1 2 4 1 AMT Configuration USB Provision of AMT Enable Disable of AMT BIOS Provisioning MAC Pass Through Enable Disable MAC Pass Through function Active Remote Assistance Process Trigger CIRA boot Unconfigure ME Unconfigure ME with resetting MEBx password to default on next boot ASF Configuration Conf...

Page 48: ...ble BIOS ACPI auto configuration Enable Hibernation Enables or Disables System ability to Hibernate OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed PCIE Wake Enable or disable PCIE to wake the system from S5 ...

Page 49: ...ol Brightness PWM Polarity for Native or Invert Brightness Control Enable Choose to control LVDS brightness value by EC or User override during POST stage Serial Port 1 Configuration Set Parameters of Serial Port 1 Serial Port 2 Configuration Set Parameters of Serial Port 2 Serial Port 3 Configuration Set Parameters of Serial Port 3 Serial Port 4 Configuration Set Parameters of Serial Port 4 Hardw...

Page 50: ...PI Report Method Configuration Select ACPI Reporting Method for EC Devices 4 1 2 6 1Serial Port 1 Configuration Serial Port Enable or Disable Serial Port COM Change Settings Select an optimal settings for Super IO device COM Port Mode COM Port Mode Select ...

Page 51: ...l Port 2 Configuration Serial Port Enable or Disable Serial Port COM Change Settings Select an optimal settings for Super IO device COM Port Mode COM Port Mode Select 4 1 2 6 3Serial Port 3 Configuration Serial Port Enable or Disable Serial Port COM Change Settings ...

Page 52: ... 44 Select an optimal settings for Super IO device 4 1 2 6 4Serial Port 4 Configuration Serial Port Enable or Disable Serial Port COM Change Settings Select an optimal settings for Super IO device 4 1 2 6 5Hardware Monitor ...

Page 53: ...2 6 6Watch Dog Timer Configuration Watch Dog Timer Enable or Disable Watch Dog Timer Function 4 1 2 6 7GPIO Configuration GPIO Control Enable Choose to control GPIO by EC or user override during POST stage GPIO0 1 2 3 4 5 6 7 Configure GPIO0 1 2 3 4 5 6 7 ...

Page 54: ...od for EC Devices Active High Speed COM Port Select to Enable High Speed COM Port or Standard COM Port ACPI Report Method for I2C Bus Select ACPI Reporting Method for EC I2C Bus ACPI Report Method for CAN Bus Select ACPI Reporting Method for EC CAN Bus ACPI Report Method for GPIO Select ACPI Reporting Method for EC GPIO ...

Page 55: ... Schedule an Operation for the Security Device Platform Hierarchy Enable or Disable Platform Hierarchy Storage Hierarchy Enable or Disable Storage Hierarchy Endorsement Hierarchy Enable or Disable Endorsement Hierarchy Physical Presence Spec Version Select to Tell O S to support PPI Spec Version 1 2 or 1 3 Device Select TPM 1 2 will restrict support to TPM 1 2 devices TPM 2 0 will restrict support...

Page 56: ...dTime system will wake on the hr min sec specified 4 1 2 9 Serial Port Console Redirection Console Redirection This item allows users to configuration console redirection detail settings Console Redirection EMS This item allows users to enable or disable console redirection for Microsoft Windows Emergency Management Services EMS ...

Page 57: ...1 USB Configuration Legacy USB Support Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI owner ship change should be claimed by XHCI driver ...

Page 58: ...s Device reset time out USB mass storage device start unit command time out Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor 4 1 2 12 Network Stack Configuration Network Stack Enable Disable UEFI Network Stack ...

Page 59: ...p Response BIOS reaction on INT19 trapping by Option ROM IMMEDIATE execute the trap right away POSTPONED execute the trap during legacy boot Boot option filter This option controls Legacy UEFI ROMs priority Network Controls the execution of UEFI and Legacy PXE OpROM Storage Controls the execution of UEFI and Legacy Storage OpROM Video Controls the execution of UEFI and Legacy Video OpROM Other PCI...

Page 60: ...the Chipset tab from the MIO 5377 setup screen to enter the Chipset BIOS Setup screen You can display a Chipset BIOS Setup option by highlighting it using the Arrow keys All Plug and Play BIOS Setup options are described in this sec tion The Plug and Play BIOS Setup screen is shown below ...

Page 61: ...TCSS setup menu TCSS Configuration settings Display setup menu Display Configuration settings Stop Grant Configuration Automatic Manual stop grant configuration VT d VT D capability Control Iommu Pre boot Behavior Enable IOMMU in Pre boot environment X2APIC Opt Out Enable Disable X2APIC Opt Out Bit DMA Control Guarantee Enable Disable DMA_CONTROL_GUARANTEE bit Above 4GB MMIO BIOS assigment Enable ...

Page 62: ...oot Max TOLUD Maximum Value of TOLUD SA GV System Agent Geysetville Gear Ratio Gear ratio when SAGV is disabled Memory Scrambler Enable Disable Memory Scrambler support Force ColdReset Force ColdReset OR Choose MrcColdBoot mode In Band ECC Support Enable Disable In Band ECC Memory Remap Enable Disable Memory Remap above 4GB ...

Page 63: ...aphics Turbo IMON Current Graphics turbo IMON current values supported GTT Size Select the GTT Size Aperture Size Select the Aperture Size PSMI Support Enable Disable PSMI DVMT Pre Allocated Select DVMT 5 0 Pre Allocated Fixed Graphics Memory size used by the Internal Graphics Device ...

Page 64: ...ion DMI Gen3 Eq Phase 2 Perform Gen3 Equalization Phase 2 DMI Gen3 Eq Phase 3 Method Select Method for Gen3 Equalization Phase 3 DMI Gen3 ASPM DMI Gen3 ASPM Support 4 1 3 1 4TCSS setup menu TCSS xHCI Support Enable Disable TCSS xHCI ITBT PECI1 Root Port ...

Page 65: ...ble ITBT DMA0 4 1 3 1 5Display setup menu NXP Non EDID Support Non EDID Support Color Depth Data Packing Color depth and data packing format for Non EDID Support Dual LVDS Mode Select LVDS bus to Single bus mode or Dual bus mode LVDS Panel Type This item allow user to select LVDS panel resolution type ...

Page 66: ...nfiguration Settings PCH LAN Controller Enable or Disable onboard NIC Wake on LAN Enable Enable or Disable Integrated LAN to wake the system LAN1 PXE ROM Enable or disable boot option for LAN1 Controller Onboard LAN2 Controller Select to Enable or Disable onboard LAN2 Controller LAN2 PXE ROM Enable or disable boot option for LAN2 Controller Restore AC Power Loss Specify what state to go to when po...

Page 67: ...ASPM Control This item controls Active State Power Management of the DMI Link PCI Express Root Port 5 12 PCI Express Port 5 12 Settings 4 1 3 2 2SATA Configuration SATA Controller s Enable Disable SATA Device SATA Mode Selection Determine how SATA controller operate SATA Controller Speed Limit ...

Page 68: ...Well Power Gating Select Enabled to enable SUS Well PG for USB2 PHY USB Overcurrent Select Enabled if Overcurrent functionality is used USB Overcurrent Lock Select Enabled if Overcurrent functionality is used USB3 1 Speed Selection USB3 1 Speed selection GEN1 or GEN2 USB Port Disable Override Selectively Enable Disable the corresponding USB Port from reporting a Device Connection to the Controller...

Page 69: ...28 byte bank of RTC RAM BIOS Lock Enable or Disable the PCH BIOS Lock Enable feature Force unlock on all GPIO pads If Enabled BIOS will force all GPIO pads to be in unlock state 4 1 3 2 5HD Audio Configuration HD Audio Control Detection of the HD Audio device Disabled HDA will be uncondition ally disabled Enabled HDA will be unconditionally Enabled ...

Page 70: ...O I2C0 I2C1 Settings Configure SerialIo Controller SerialIO timing parameters Enable additional timing parameters for all SerialIO controllers 4 1 4 Security Select Security Setup from the MIO 5377 Setup main BIOS setup menu All Security Setup options such as password protection and virus protection are described in this ...

Page 71: ...original default boot selection A value of 0 indicates that the default boot selection is to be initiated immediately on boot A value of 65535 0xFFFF indicates that firm ware will wait for user input before booting This means the default boot selec tion is not automatically started by the firmware Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot opti...

Page 72: ... to rest system setup without saving any changes Save Changes This item allows you to save changes done so far to any of the options Discard Changes This item allows you to discard changes done so far to any of the options Restore Defaults This item allows you to restore load default values for all the options Save as User Defaults This item allows you to save the changes done so far as user defau...

Page 73: ...Appendix A A ...

Page 74: ... Controller B0h B1h Interrupt Controller B4h BDh Power Management 200h 27Fh CANBus Controller 280h 28Fh I2C Controller 290h 29Fh EC Index port and Data port 2A0h 2BFh GPIO Controller 2C0h 2DFh SMBus Controller 2E8h 2EFh Communications Port COM4 2F0h 2F7h EC PMC Controller 2F8h 2FFh Communications Port COM2 300h 37Fh CANBus Controller 3E8h 3EFh Communications Port COM3 3F8h 3FFh Communications Port...

Page 75: ...ntel HD Graphic 00000h 9FFFFh System board A 4 Interrupt Assignments Interrupt Interrupt source NMI Parity error detected IRQ0 System timer IRQ1 Using SERIRQ Keyboard Emulation IRQ2 Interrupt from controller 2 cascade IRQ3 Communications Port COM2 IRQ4 Communications Port COM1 IRQ5 EC Watch Dog IRQ6 CANBus Controller IRQ7 Communications Port COM3 IRQ8 System CMOS real time clock IRQ9 Microsoft ACP...

Page 76: ...re subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permission from the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2023 ...

Reviews: