LR77 v2
7. Technical Parameters
7.1
Basic parameters
LR77 v2
Temperature range
Operating
Storage
-40
◦
C to +75
◦
C
∗
-40
◦
C to +85
◦
C
Humidity
Operating
Storage
0 to 95 % relative humidity non condensing
0 to 95 % relative humidity non condensing
Altitude
Operating
2000 m / 70 kPa
Degree of protection
IP30
Supply voltage
9 to 36 V DC
Baterry for RTC
CR1225
Consumption
Idle
GPRS
LTE
2.3 W
to 3.5 W (GPRS transmission)
to 5.5 W (LTE transmission)
Dimensions
Plastic box
Metal box
51 x 87 x 116 mm (DIN 35 mm)
42 x 87 x 113 mm (DIN 35 mm)
Weight
LR77 v2 – 150 g
LR77 v2 SL – 280 g
Antenna connector
3x SMA – 50 Ohm
User interface
ETH
USB
PORT1
PORT2
Ethernet (10/100 Mbps)
USB 2.0
On customer’s request
On customer’s request
Table 16: Basic parameters
∗
Temperature range for routers supporting 450 MHz is reduced to -20
◦
C to +60
◦
C!
29
04-09-19
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: [email protected] — www.lucom.de
www