UNO-2050E User Manual
12
Interrupt Enable Control Function
The user can choose to enable or disable the interrupt function by writing
its corresponding value to the interrupt disable/enable control bit in the
interrupt control register, as shown in Table 2-4
Interrupt Triggering Edge Control
The interrupt can be triggered by a rising edge or a falling edge of the
interrupt signal, as determined by the value in the interrupt triggering
edge control bit in the interrupt control register, as shown in Table 2-5.
Interrupt Flag Bit
The interrupt flag bit is a flag indicating the status of an interrupt. It is a
readable/writable bit. To find the status of the interrupt, you have to read
the bit value; to clear the interrupt, you have to write “1” to this bit. This
bit must first be cleared to service the next coming interrupt
Table 2.4: Interrupt Disable/Enable C. Bit Values
DI0EN & DI1EN
Interrupt Disable/Enable Control
0
Disable
1
Enable
Table 2.5: Interrupt Triggering Edge C. Bit Values
DI0TE & DI1TE
Triggering Edge of Interrupt Signal
0
Falling edge trigger
1
Rising edge trigger
Table 2.6: Interrupt Flag Bit Values
DI0F & DI1F
Interrupt Status
Read
0
No interrupt
1
Interrupt occur
Write
0
Don’t care
1
Clear interrupt.