background image

 

User Manual FWA-3050

_ v0.2 20200207.docx

Copyright 

2017

  Advantech Co. Ltd. All rights reserved.

 

       

               

 

                 

 

Page 32 

 

2. When set Network Stack is enabled, and then go to item of “ BIOS/ Advanced-> CSM Parameters -> 
Network” to enable PXE ROM function, set it as “Legacy” (IPV4 PXE) function .  

 

 

3. Save BIOS and reboot system. The BIOS will show “Checking Media Presence......”, if system is not 
connected PXE server, it will show “No Media Present......” 

Summary of Contents for FWA-3050

Page 1: ...Copyright 2014 Advantech Co Ltd All rights reserved USER MANUAL REVISION 0 2 DATE 2020 02 07 FWA 3050 1U RACKMOUNT NETWORK APPLIANCE...

Page 2: ...r View 15 1 3 SYSTEM LAYOUT 16 1 4 BLOCK DIAGRAM 17 2 CONNECTOR LIST AND JUMPER AND SWITCH SETTING 18 2 1 CONNECTOR JUMPER AND SWITCH PLACEMENT 18 2 2 CONNECTOR LIST 18 2 3 JUMPER SETTING 21 2 4 SWITC...

Page 3: ...ll rights reserved Page 3 5 BIOS 35 5 1 BIOS DEFAULTS 35 5 2 BIOS SETUP MENU 35 5 2 1 Main Setup Menu 37 5 2 2 Platform Setup Menu 38 5 2 3 Hardware setup menu 52 5 2 4 Server Mgmt setup menu 65 5 2 5...

Page 4: ...ment Menu 49 Table 15 Advantech Lan Bypass Menu 51 Table 16 Processor Configuration Menu 54 Table 17 Northbridge Configuration Menu 55 Table 18 Hardware Setup PCI Subsystem Menu Items 58 Table 19 Hard...

Page 5: ...S Setup Main screen 37 Figure 19 Platform Setup Main screen 39 Figure 20 Platform Setup Console Redirection Menu 39 Figure 21 Platform Setup USB Configuration Menu 41 Figure 22 Platform Setup Trusted...

Page 6: ...are Setup ACPI configuration 63 Figure 38 Hardware Setup Runtime Error logging configuration 64 Figure 3839 Server Mgmt configuration 65 Figure 3940 BMC Network Configuration 66 Figure 410 Boot Config...

Page 7: ...vements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior writ...

Page 8: ...SSEMENT Les avertissements indiquent des conditions qui si elles ne sont pas observ es peuvent provoquer des blessures Caution Cautions are included to help you avoid damaging hardware or losing data...

Page 9: ...r safety reasons the equipment should be opened only by qualified service personnel 14 If one of the following situations arises get the equipment checked by service personnel The power cord or plug i...

Page 10: ...er un incendie ou un choc lectrique 13 N ouvrez jamais l quipement Pour des raisons de s curit l quipement doit tre ouvert uniquement par du personnel qualifi 14 Si l une des situations suivantes se p...

Page 11: ...armful interference in which case the user will be required to correct the interference at his own expense Cet appareil est conforme la partie 15 des r gles de la FCC Le fonctionnement est soumis aux...

Page 12: ...d only by professionals Remarque L quipement est exploit et entretenu uniquement par des professionnels Technical Support and Assistance 1 Visit the Advantech web site at www advantech com support whe...

Page 13: ...ing the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think...

Page 14: ...User Manual FWA 3050_ v0 2 20200207 docxCopyright 2017 Advantech Co Ltd All rights reserved Page 14 1 SPECIFICATION 1 1 Overview Table 2 Specification...

Page 15: ...opyright 2014 Advantech Co Ltd All rights reserved 1 2 System Outlook 1 2 1 FRONT VIEW 1 2 1 1 I O and NMC Figure 1 I O and NMC 1 2 1 2 LED Button Figure 2 LED Button 1 2 2 REAR VIEW Figure 3 Rear vie...

Page 16: ...Copyright 2014 Advantech Co Ltd All rights reserved 1 3 System layout System layout as below picture Figure 4 System layout...

Page 17: ...Copyright 2014 Advantech Co Ltd All rights reserved 1 4 Block Diagram Figure 5 Block diagram...

Page 18: ...eserved Page 18 2 CONNECTOR LIST AND JUMPER AND SWITCH SETTING 2 1 Connector Jumper and Switch Placement Figure 6 Jumper and switch placement 2 2 Connector List Connector Jumper Name Function DIMM_A1...

Page 19: ...ector CN19 M 2 1 connector CN16 M 2 2 connector CN34 BSCAN2 CONNECTOR CN25 SATA 1 POWER CONNECTOR CN26 SATA 2 POWER CONNECTOR CN35 CPU core power VCC PWM download pin header CN17 SATA 1 CONNECTOR CN18...

Page 20: ...20200207 docxCopyright 2017 Advantech Co Ltd All rights reserved Page 20 CN27 POE connector CN6 VGA connector CN29 SFP 2x1 connector CN30 SFP 2x1 connector CN11 RJ45 1x4 connector CN10 RJ45 1x4 connec...

Page 21: ...OVERRIDE DISABLE 2 4 DEFAULT FLASH SECURITY OVERRIDE ENABLE JP4 1 4 DEFAULT NORMAL RTC RESET 2 5 DEFAULT CLEAR RTC REGISTERS JP8 Open DEFAULT Normal Short FORCE FM_PS_EN_PSU_N Low JP14 Open FORCE SWIT...

Page 22: ...ch Co Ltd All rights reserved Page 22 3 INSTALLATION GUIDE 3 1 CPU Heatsink FWA 3050 main board supports INTEL XEON D 2100 processor family Installation steps as below Step1 Tighten screw by the instr...

Page 23: ...DIMMs with 2666 2400 2133MHz memory ECC RDIMM Please insert DRAM on slots 1 as shown in picture below Figure 8 DRAM installation Note 1 A DRAM channel is separated for one black and one blue slot Ple...

Page 24: ...ts 2 of internal 2 5 HDD by SKU 2 M 2 2280 SSD 1 Install external HDD Step 1 Screw 2 5 HDD or SSD with 2 holes on both sides Figure 10 HDD installation Step 2 Pull in HDD kit into system 2 M 2 Install...

Page 25: ...ile and full high half length running on PCIe Gen3 x8 Step 1 Remove the PCIE riser holder and insert PCIe add on cards on it Figure 12 PCIE installation 3 5 2 Post Installation Guide 3 5 1 Overview Th...

Page 26: ...ght 2017 Advantech Co Ltd All rights reserved Page 26 3 6 Slide Rail Installation Guide 3 6 1 Overview This guide is for FWA 3050 s slide rail Advantech PN 968AE00073 it s optional kit please purchase...

Page 27: ...User Manual FWA 3050_ v0 2 20200207 docxCopyright 2017 Advantech Co Ltd All rights reserved Page 27 Step 1 Step 2...

Page 28: ...User Manual FWA 3050_ v0 2 20200207 docxCopyright 2017 Advantech Co Ltd All rights reserved Page 28 Step 3 Step 4...

Page 29: ...NMC component FWA 3050 supports 1x Network Mezzanine Cards NMCs space in front panel Insert NMC alone with guiding rail and fasten it by thumbs screws Figure 13 NMC installation 3 8 Install remove Pow...

Page 30: ...User Manual FWA 3050_ v0 2 20200207 docxCopyright 2017 Advantech Co Ltd All rights reserved Page 30 Figure 14 PSU installation...

Page 31: ...On Standby button for more than 4 seconds to force the server to enter standby mode This method forces the server to enter standby mode without properly exiting applications and the OS If an applicat...

Page 32: ...2 When set Network Stack is enabled and then go to item of BIOS Advanced CSM Parameters Network to enable PXE ROM function set it as Legacy IPV4 PXE function 3 Save BIOS and reboot system The BIOS wi...

Page 33: ...o Ltd All rights reserved Page 33 4 User may re login in BIOS choose BIOS boot item it will has Network Device BBS Priorities item and set UEFI PXE LAN boot sequence priority And please choose PXE Boo...

Page 34: ...cess and required configuration of such network install will heavily depend on the target OS and boot loader miniOS used Please refer to the related documentation available PXE boot requires a DHCP se...

Page 35: ...tery 5 1 BIOS Defaults The BIOS comes with a set of configuration parameters when shipped by Advantech referred to as Optimized Defaults or factory defaults The user can change BIOS settings via the s...

Page 36: ...OST The BIOS setup menu screens have a few main elements as shown below The menu bar displays the selectable menu pages as tabs The parameter window displays and allows configuration of the settings a...

Page 37: ...in setup screen by selecting the Main tab Figure 17 BIOS Setup Main screen The main setup page displays system a summary of system and BIOS configuration and status information The fields on this page...

Page 38: ...he system time and date Highlight System Time or System Date using the Arrow keys Enter new values through the keyboard Press the Tab key or the Arrow keys to move between fields The date must be ente...

Page 39: ...rm Setup Main screen 5 2 2 1 Serial Console This sub menu allows you to change the settings used for the serial console Note that the serial console is always using COM1 which is connected to the fron...

Page 40: ...es number of data bits in a character Parity None Even Odd Mark Space Defines the parity scheme used Stop Bits 1 2 Defines number of stop bits in a character Flow Control None Xon Xoff Defines the flo...

Page 41: ...of the USB devices detected by the BIOS Figure 20 Platform Setup USB Configuration Menu Group Setup item Access Options Description None USB Support Enabled Disabled Enables or disables the support fo...

Page 42: ...ake before it properly reports itself to the Host Controller Device power up delay 5 Table 9 USB Configuration Menu 5 2 2 3 Trusted Computing Please note that Trusted Computing support is disabled by...

Page 43: ...en system with TPM2 0 module installed and the BIOS will auto detect it and the related setting will be shown in the BIOS setup menu as below Figure 22 Platform Setup Trusted Computing with TPM2 0 Gro...

Page 44: ...M2 0 UEFI Spec Version TCG_2 TCG_1_2 Select the TCG2 Spec Version Support TCG_1_2 the Compatible mode for Win8 Win10 TCG_2 Support new TCG2 protocol and event format for Win10 or later Physical Presen...

Page 45: ...e Sup Enable Disable BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available TPM State Enable Disable Enable Disable Security Devi...

Page 46: ...Advantech Co Ltd All rights reserved Page 46 5 2 2 5 H W Monitor This sub menu allows you to see all the H W monitor items detected by the BIOS when system is without BMC for well know the current sys...

Page 47: ...assigned to virtual machines in pass through mode This applies for all PCIe devices Figure 25 Platform Setup Virtualization Group Setup item Access Options Description None Intel Virtualization Enabl...

Page 48: ...ions Description None EIST Enable Disable Enable or disable BIOS support for Enhanced Intel SpeedStep Technology When enabled OS sets CPU frequency according load When disabled CPU frequency is set at...

Page 49: ...log is full Clear Log Do not log any more Select the action to be taken when log is full System event log SEL Components Enable Disable Change this to enable or disable all features of System Event L...

Page 50: ...ass settings Group Setup item Access Options Description Advantech Lan Bypss Config Lan Bypass Devices None Slot1 1 LBP Control Slot1 2 LBP Control Select which Slot to control Lan Bypass Config Lan B...

Page 51: ...NMC When watch dog start Watch Dog Time Out status Display only The current Status of Lan Byass in watch dog time out Watch Dog Time Out Connect Disconnect Bypass Select the action of Lan bypass for...

Page 52: ...set is a legacy term and the related functionality is split over the CPU and PCH portions of the SoC Similarly the terms South Bridge and North Bridge are legacy terms and do not represent the silicon...

Page 53: ...Displays information on the processor installed Microcode Patch CPU Frequency Processor Cores Intel VT x Technology L1 code Cache L2 Cache L3 Cache None Hyper threading Enable Disable Enables Hyper Th...

Page 54: ...ch feature MLC Spatial Prefetcher MSR 1A4h Bit 1 DCU Streamer Prefetch Enable Disable Enable or disable DCU Streamer Prefetcher feature DCU streamer prefetcher is an L1 data cache prefetcher MSR 1A4h...

Page 55: ...ry in system to be mirrored Memory Rank Sparing Enable Disable Memory Rank Sparing enable disable IMC Interleaving Auto 1 way Interleave 2 way Interleave Select IMC Interleaving settings Channel Inter...

Page 56: ...these settings still apply to the platform as PCIe is using the same configuration mechanism as PCI Figure 31 Hardware Setup PCI Subsystem Group Setup item Access Options Description Socket 0 PCIe por...

Page 57: ...ORT 2A Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Settings PORT 2B Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Settings...

Page 58: ...contains settings for the UPI configuration Figure 32 Hardware Setup UPI configuration PORT 3B Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Settings PORT 3C Link...

Page 59: ...speed slow Link Frequency Select Auto 10 4 GB s 9 6 GB s Use Per Link Setting Allows for Selecting the UPI link frequency Link0p Enable Enabled Disabled Enable disable Link0 Link1p Enable Enabled Dis...

Page 60: ...ttings N A Select sub menu Runtime Error Logging N A Select sub menu PCH Compatibility RID Enable Disable Enable or Disable PCH s CCRID SMBus Controller Enable Disable Enable or Disable SMBus CDevice...

Page 61: ...SATA Mode AHCI RAID 1 AHCI Mode 2 RAID Mode SATA Controller Enabled Disabled To enable the SATA controller sSATA Mode AHCI RAID 1 AHCI Mode 2 RAID Mode sSATA Controller Enabled Disabled To enable the...

Page 62: ...bled Disabled Enable Disable this USB Physical Connector physical port USB Port 1 Disable Enabled Disabled Enable Disable this USB Physical Connector physical port USB 3 0 Port 0 Disable Enabled Disab...

Page 63: ...Auto Configuration Enabled Disabled Enable or disable BIOS ACPI auto configuration Enable Hibernation Enabled Disabled Enable the system ability to hibernate OS S4 sleep state this option may be not...

Page 64: ...g This sub menu contains settings for the Runtime error logging configuration Figure 37 Hardware Setup Runtime Error logging configuration Group Setup item Access Options Description None System Error...

Page 65: ...Watchdog Timer Enable Disable If enabled starts a BIOS timer which can only be shut off by Management Software after the OS loads Helps determine that the OS successfully loaded or follows the OS Boo...

Page 66: ...mically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Current Configuration Address source Display only Current LAN Configuration statically or dynamic...

Page 67: ...he application Figure 400 Boot Configuration Table 277 Boot Configuration Feature Default Description Setup Prompt Timeout 1 Number of seconds to wait for setup activation key Bootup NumLock State On...

Page 68: ...tion Menu Group Setup item Access Options Description None CSM Support Enabled Disabled Enables or disables the Compatibility Support Module Boot option filter UEFI and Legacy Legacy Only UEFI Only Th...

Page 69: ...y BIOS CSM16 Figure 422 CSM16 Configuration Group Setup item Access Options Description None GateA20 Active Upon Request Always UPON REQUEST GA20 can be disabled using BIOS services ALWAYS do not allo...

Page 70: ...oots and or an attempt is made to enter the Setup program Figure 433 Administrator Setup Note If set the Password Check is Setup then this only limits access to Setup and is only asked for when enteri...

Page 71: ...ve Changes and Exit Exit setup after saving the changes Does not update User defaults Discard Changes and Exit Exit setup without saving any changes Save Changes and Reset Reset system after saving th...

Page 72: ...ll rights reserved Page 72 Restore User Defaults Restores the User defaults to all the setup options Boot Override UEFI boot device This option allows you to override the specified boot order and use...

Reviews: