background image

 

55                                                                                  Chapter3 

  Speed: set the port link speed. 

  Duplex: set full-duplex or half-duplex mode of the port. 

  Flow Control: set flow control function as Enable or Disable in Full Duplex mode. The default 

    value is Enable. 

  Security: when its state is “On” that means this port accepts only one MAC address. 

  Click 

Apply

 button to apply the configuration. 

 

 

Figure 3.24: Port Control 

 
 

Port Trunk 

 

The  Link  Aggregation  Control  Protocol  (LACP)  provides  a  standardized  means  for  exchanging 
information between Partner Systems on a link to allow their Link Aggregation Control instances to reach 
agreement on the identity of the Link Aggregation Group to which the link belongs, move the link to that 
Link Aggregation Group, and enable its transmission and reception functions in an orderly manner. Link 
aggregation  lets  you  group  up  to  4  ports  into  one  dedicated  connections.  This  feature  can  expand 
bandwidth  to  a  device  on  the  network.  LACP  operation  requires  full-duplex  mode;  for  more  detail 
information please refers to IEEE 802.3ad. 

 

Aggregator setting 

 

  System Priority: a value used to identify the active LACP. The switch with the lowest value has the 

    highest priority and is selected as the active LACP. 

  Group ID: There are four trunk groups to provide configure. Choose the "Group ID" and click

Select

  LACP: If enable, the group is LACP dynamic trunk group. If disable, the group is static trunk group. 

    All ports support LACP dynamic trunk group. If connecting to the device that also supports LACP, the 
    LACP dynamic trunk group will be created automatically. 

  Work ports: allows max four ports to be aggregated at the same time. With LACP dynamic trunk 

    group, the exceed ports are standby and can be aggregated if work ports fail. If it is static trunk group, 
    the number of ports must be the same as the group member ports. 

  Select the ports to join the trunk group. Allows max four ports to be aggregated at the same time. Click 

    

Add

 button to add the port. To remove unwanted ports, select the port and click 

Remov

 button. 

Summary of Contents for EKI-7659CPI

Page 1: ...EKI 7659CPI 8 2G Combo Ports Industrial PoE Managed Redundant Gigabit Ethernet Switch User Manual ...

Page 2: ...m or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS...

Page 3: ...placement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer an...

Page 4: ...diate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web sit...

Page 5: ...nything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service ...

Page 6: ...amage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components ...

Page 7: ...of EKI 7659CPI 14 Figure 2 4 Top View of EKI 7659CPI 15 2 3 Mounting 16 2 3 1 Wall mounting 16 Figure 2 5 Combine the Metal Mounting Kit units mm 16 2 3 2 DIN rail Mounting 17 Figure 2 6 Installation to DIN rail Step 1 17 Figure 2 7 Installation to DIN rail Step 2 18 2 4 Network Connection 19 2 5 Connection to a Fiber Optic Network 19 Figure 2 8 Transceiver to the SFP module 19 Figure 2 9 Transcei...

Page 8: ...ommands Set 34 3 1 11 SNMP Commands Set 34 Table 3 11 SNMP Commands Set 34 3 1 12 Port Mirroring Commands Set 35 Table 3 12 Port Mirroring Commands Set 35 3 1 13 802 1x Commands Set 35 Table 3 13 802 1x Commands Set 35 3 1 14 TFTP Commands Set 36 Table 3 14 TFTP Commands Set 36 3 1 15 SystemLog SMTP and Event 36 Table 3 15 SysLog SMTP Event Commands Set 36 3 1 16 SNTP Commands Set 37 Table 3 16 SN...

Page 9: ... 802 1Q Group Configuration 64 Figure 3 35 802 1Q Group Configuration Edit 64 Figure 3 36 RSTP System Configuration interface 66 Figure 3 37 RSTP Port Configuration interface 66 Figure 3 38 SNMP System Configuration interface 67 Figure 3 39 Trap Configuration interface 68 Figure 3 40 SNMP V3 configuration interface 69 Figure 3 41 QoS Configuration interface 72 Table 3 19 IGMP types 73 Figure 3 42 ...

Page 10: ...EKI 7659CPI_Manual_ed33 x Figure A 2 EIA TIA 568B 86 Figure A 3 EIA TIA 568A 86 Figure A 4 DB 9 pin female connector 87 Appendix B Compatible SFP Modules 90 ...

Page 11: ...1 Chapter1 Overview Sections include Introduction Features Specifications Packing List Safety Precaution CHAPTER ...

Page 12: ...ng and implementing a network The slots can accept any SFP type fiber module and these modules are designed for transmitting over distances of either 500m multi mode 10km 30km 50km 70km or 110km single mode and the slots support SFP modules for WDM single fiber transmissions This means that you can easily change the transmission mode and distance of the switch by simply pulling out the SFP module ...

Page 13: ...C EFT protection which secure equipment against unregulated voltage and make systems safer and more reliable Meanwhile 4 000 VDC ESD protections for Ethernet ports make EKI 7659CPI more suitable for harsh environments 1 1 7 Wide Operating Temperature The operating temperature of the EKI 7659CPI is between 10 60 With such a wide range you can use the EKI 7659CPI in some of the harshest industrial e...

Page 14: ...speed recovery time 10ms RSTP STP 802 1w 1D Management Web Telnet Serial Console Windows Utility and SNMP Control VLAN GVRP QOS IGMP Snooping LACP and Rate Limit Security IP MAC and port binding DHCP Server IP access list 802 1x SNMPv3 Diagnostic Port Statistic Port Mirroring RMON Trap SNMP Alert and Syslog Supports 48 VDC power input Robust mechanism and special heat spreader design ...

Page 15: ...0 Mbps Gigabit Fiber Up to 1000Mbps Interface Connectors 8 x RJ 45 Ethernet 2 x RJ 45 SFP mini GBIC combo ports 6 pin removable screw terminal power Relay LED Indicators System PWR PWR1 PWR2 R M P Fail 10 100TX Link Activity Duplex Collision Gigabit Copper Link Activity Speed 1000Mbps SFP Link Activity Console RS 232 RJ 45 Power Power Consumption 116 W Power Input 2 x Unregulated 48 VDC Fault Outp...

Page 16: ...ng Humidity 5 95 non condensing Storage Temperature 40 85 40 185 Storage Humidity 5 95 non condensing MTBF 190287 hours Certifications Safety UL 60950 1 CAN CSA C22 2 No 60950 EMC EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 EN61000 6 2 Freefall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 ...

Page 17: ...OM with User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x 8 pin RJ 45 to RS 232 serial cable 1 x DC Jack Cable φ2 0 150mm 1 x EKI 7659CPI Startup Manual 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input ...

Page 18: ...EKI 7659CPI_Manual_ed33 8 ...

Page 19: ...9 Chapter2 Installation Sections include LED Indicators Dimensions Mounting Network Connection Connection to a Fiber Optic Network Power Connection CHAPTER ...

Page 20: ...reen On Power input 2 is active Off Power input 2 is inactive P Fail Red On Power input 1 or 2 is inactive or port link down depends on Fault Relay Alarm configuration Off Power input 1 and 2 are both active or no power input Link Active for G9 G10 SFP Green On SFP port is linking Flashing Data is transmitting or receiving Off Not connected to network G9 G10 RJ 45 Green Upper LED On The port is op...

Page 21: ...11 Chapter2 PoE P1 P8 Green On A powered device is connected utilizing Power over Ethernet on the port Off No device is connected or power forwarding fails ...

Page 22: ...EKI 7659CPI_Manual_ed33 12 2 2 Dimensions units mm Figure 2 1 Front View of EKI 7659CPI ...

Page 23: ...13 Chapter2 Figure 2 2 Side View of EKI 7659CPI ...

Page 24: ...EKI 7659CPI_Manual_ed33 14 Figure 2 3 Rear View of EKI 7659CPI ...

Page 25: ...15 Chapter2 Figure 2 4 Top View of EKI 7659CPI ...

Page 26: ...wall mounted by using the included mounting kit Then hang on the EKI 7659CPI to the nails on the wall First use the screws included in the package to combine the EKI 7659CPI and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below Figure 2 5 Combine the Metal Mounting Kit units mm ...

Page 27: ...he DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 7659CPI to the DIN rail with angle of inclination See Figure 2 6 Figure 2 6 Installation to DIN rail Step 1 ...

Page 28: ...EKI 7659CPI_Manual_ed33 18 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 ...

Page 29: ...lick is heard You can use proper multi mode or single mode fiber according to the used SFP module With fiber optic it transmits speed up to 1000 Mbps and you can prevent noise interference from the system and transmission distance up to 110 km depending on the mini GBIC module The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunica...

Page 30: ...EKI 7659CPI_Manual_ed33 20 Figure 2 9 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver Figure 2 10 LC connector to the transceiver ...

Page 31: ... the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Figure 2 11 Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Figure 2 12 Pull out from the transceiver ...

Page 32: ...power fail relay output Figure 2 8 Pin Assignment of the Power Connector You can connect an alarm indicator buzzer or other signaling equipment through the relay output The relay opens if power input 1 2 fails or port link down break Open means if you connect relay output with an LED the light would be off ...

Page 33: ...23 Chapter2 ...

Page 34: ...EKI 7659CPI_Manual_ed33 24 Configuration Sections include RS 232 Console Web Browser Mounting Self Diagnosis CHAPTER ...

Page 35: ...which provides the console management CLI command Attach the supplied cable which one end is RJ 45 and the other end is female DB9 to connect EKI 7659CPI and your host PC or terminal The connected PC or terminal must support the terminal emulation program From the Windows desktop click Start Programs Accessories Communications HyperTerminal to open Hyper Terminal program Figure 3 1 Open Hyper Term...

Page 36: ...ity 1 for Stop Bits and None for Flow Control Figure 3 2 COM Port Properties Setting Press Enter for login screen If you can not find the login screen press Enter one more time The default user name and password are both admin Key in the user name and password to enter the command line interface Figure 3 3 Login Screen RS 232 Configuration ...

Page 37: ...nter disable to exit The privileged command is the advance mode Use this mode to Display advanced function status save configuration Global configuration Enter the configure command while in privileged EXEC mode switch config To exit to privileged EXEC mode enter exit or end Use this mode to configure the parameters that are going to be applied to your switch VLAN database Enter the vlan database ...

Page 38: ...em information switch show system info ip address Ip address Subnet mask Gateway G Configure the IP address of switch switch config ip address 192 168 1 1 255 255 255 0 192 168 1 254 ip dhcp G Enable DHCP client function of switch switch config ip dhcp show ip P Show IP information of switch switch show ip no ip dhcp G Disable DHCP client function of switch switch config no ip dhcp reload G Halt a...

Page 39: ...ver switch config security telnet security ip Index 1 10 IP Address G Set the IP security list switch config security ip 1 192 168 1 55 show security P Show the information of IP security switch show security no security G Disable IP security function switch config no security no security http G Disable IP security of HTTP server switch config no security http no security telnet G Disable IP secur...

Page 40: ...switch config if show bandwidth state Enable Disable I Use the state interface configuration command to specify the state mode of operation for Ethernet ports Use the disable form of this command to disable the port switch config interface fastEthernet 2 switch config if state Disable show interface configuration I show interface configuration status switch config interface fastEthernet 2 switch c...

Page 41: ...dd new port based VALN switch vlan vlan port based grpname test grpid 2 port 2 4 or switch vlan vlan port based grpname test grpid 2 port 2 3 4 show vlan GroupID or show vlan V Show VLAN information switch vlan show vlan 23 no vlan group GroupID V Delete port base group ID switch vlan no vlan group 2 IEEE 802 1Q VLAN vlan 8021q name GroupName vid VID V Change the name of VLAN group if the group di...

Page 42: ...rval between messages the spanning tree receives from the root switch If a switch does not receive a bridge protocol data unit BPDU message from the root switch within this interval it recomputed the Spanning Tree Protocol STP topology switch config spanning tree max age 15 spanning tree hello time seconds G Use the spanning tree hello time global configuration command to specify the interval betw...

Page 43: ...onfig qos prioritytype qos priority portbased Port lowest low middle high G Configure Port based Priority switch config qos priority portbased 1 low qos priority cos Priority lowest low middle high G Configure COS Priority switch config qos priority cos 0 middle qos priority tos Priority lowest low middle high G Configure TOS Priority switch config qos priority tos 3 high show qos P Displays the i...

Page 44: ...system location System Location G Set SNMP agent system location switch config snmp system location lab snmp system contact System Contact G Set SNMP agent system contact switch config snmp system contact where snmp agent mode v1v2c v3 v1v2cv3 G Select the agent mode of SNMP switch config snmp agent mode v1v2cv3 snmp community strings Community right RO RW G Add SNMP community string switch config...

Page 45: ...ort Mirroring Commands Set Commands Level Description Example monitor rx G Set RX destination port of monitor function switch config monitor rx monitor tx G Set TX destination port of monitor function switch config monitor tx show monitor P Show port monitor information switch show monitor monitor RX TX Both I Configure source port of monitor function switch config interface fastEthernet 2 switch ...

Page 46: ...x request global configuration command to set the MAX requests switch config 8021x misc maxrequest 3 8021x misc reauthperiod sec G Use the 802 1x misc reauth period global configuration command to set the reauth period switch config 8021x misc reauthperiod 3000 8021x portstate disable reject accept authorize I Use the 802 1x port state interface configuration command to set the state of the select...

Page 47: ...e fastethernet 3 switch config if event smtp both show event P Show event selection switch show event no event device cold start G Disable cold start event type switch config no event device cold start no event authentication failure G Disable Authentication failure event type switch config no event authentication failure no event X ring topology change G Disable X ring topology changed event type...

Page 48: ...ing master switch config no Xring master no Xring couplering G Disable couple ring switch config no Xring couplering no Xring dualhoming G Disable dual homing switch config no Xring dualhoming 3 1 18 PoE Commands Set Table 3 18 PoE Commands Set Commands Level Description Example poe P Enter POE configure mode switch poe system knockoff disabled Enable Disable P Set PoE system Port Knockoff Disable...

Page 49: ...at any one of PCs on the network can connect with the industrial switch through the web browser The industrial switch default value of IP subnet mask username and password are as below IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 254 User Name admin Password admin Open Internet Explorer and type EKI 7659CPI s IP in the Address field then press Enter to open the web lo...

Page 50: ...ch Read only cannot be modified System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Displays the switch s firmware version Kernel Version Displays the kernel software version MAC Address Displays the unique hardware address assigned by manufacturer default Warning Don t set 0 for the fir...

Page 51: ... the IP address And the network DHCP server will assign the IP address for the industrial switch and displays in this column The default IP is 192 168 1 1 Subnet Mask Assign the subnet mask of the IP address If DHCP client function is enabling and then user does not need to assign the subnet mask Gateway Assign the network gateway for the industrial switch The default gateway is 192 168 1 254 DNS1...

Page 52: ...nction Enable the DHCP server function the switch system will be a DHCP server DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network Low IP Address the dynamic IP assign range Low IP address is the beginning of the dynamic IP assigns range For example dynamic IP assign range is from 192 168 1 100 192 168 1 200 192 168 1 100 will be t...

Page 53: ...e DHCP client information and displays them here Figure 3 11 DHCP Server Client Entries DHCP Server Port and IP Bindings You can assign a specific IP address which is the IP in dynamic IP assign range to the specific port When a device is connecting to the port and asks for dynamic IP assigning the system will assign the IP address to the connected device ...

Page 54: ...lity of a very basic form of FTP It provides the functions to allow the user to update the switch firmware Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server TFTP Server IP Address fill in your TFTP server IP Firmware File Name the name of firmware image And then click Apply Figure 3 13 TFTP Update Firmware TFTP Restore Configuration ...

Page 55: ...n the correct restore file name Click Apply Figure 3 14 TFTP Restore Configuration TFTP Backup Configuration You can save current Flash ROM value from the switch to TFTP server then go to the TFTP restore configuration page to restore the Flash ROM value TFTP Server IP Address fill in the TFTP server IP Backup File Name fill the file name Click Apply Figure 3 15 TFTP Backup Configuration System Ev...

Page 56: ... or disable the email alert function SMTP Server IP set up the mail server IP address when Email Alert enabled this function will then be available Sender key in a complete email address e g switch101 123 com to identify where the event log comes from Authentication mark the check box to enable and configure the email account and password for authentication when Email Alert enabled this function w...

Page 57: ... cold start action the system will issue a log event Device warm start when the device executes warm start the system will issue a log event Authentication Failure when the SNMP authentication fails the system will issue a log event X ring topology change when the X ring topology has changed the system will issue a log event Port event selection select the syslog and SMTP events for each port It h...

Page 58: ...Relay Alarm Power Failure Mark the check box to enable the function of lighting up FAULT LED on the panel when power fails Port Link Down Broken Mark the check box to enable the function of lighting up FAULT LED on the panel when ports states are link down or broken ...

Page 59: ...ylight saving time is enabled you need to configure the daylight saving time period UTC Timezone set the switch location time zone The following table lists the different location time zone for your reference Table 3 18 UTC Timezone Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Stan...

Page 60: ...4 hours 4 pm ZP5 USSR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Coast USSR Zone 7 8 hours 8 pm JST Japan Standard USSR Zone 8 9 hours 9 pm EAST East Australian Standard GST Guam Standard USSR Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight SNTP Sever URL set the SNTP server IP...

Page 61: ... Enable HTTP Server when this check box is checked the IP addresses among Security IP1 IP10 will be allowed to access via HTTP service Enable Telnet Server when checked the IP addresses among Security IP1 IP10 will be allowed to access via telnet service Security IP 1 10 Assign up to 10 specific IP address Only these 10 IP address can access and manage the switch through the Web browser And then c...

Page 62: ...n change login user name and password for the management security issue User name Key in the new user name The default is admin Password Key in the new password The default is admin Confirm password Re type the new password And then click Apply button to apply the configuration ...

Page 63: ...53 Chapter3 Figure 3 22 User Authentication ...

Page 64: ...abbers packets via this port Rx Good Packet The counts of receiving good packets via this port Rx Bad Packet The counts of receiving bad packets including undersize less than 64 bytes oversize CRC error fragments and jabbers via this port Tx Abort Packet The aborted packet while transmitting Packet Collision The counts of collision packet Packet Dropped The counts of dropped packet Rx Bcast Packet...

Page 65: ...ce on the network LACP operation requires full duplex mode for more detail information please refers to IEEE 802 3ad Aggregator setting System Priority a value used to identify the active LACP The switch with the lowest value has the highest priority and is selected as the active LACP Group ID There are four trunk groups to provide configure Choose the Group ID and click Select LACP If enable the ...

Page 66: ...ge Click Apply Use Apply button to delete Trunk Group Select the Group ID and click Delete button Figure 3 25 Aggregator Setting Aggregator Information When you have set up the aggregator setting with LACP disabled you will see the local static trunk group information here Figure 3 26 Aggregator Information State Activity ...

Page 67: ...ctor after you have selected trunk port the active status will be activated automatically Figure 3 27 State Activity Port Mirroring The Port mirroring is a method for monitoring traffic in switched networks Traffic through ports can be monitored by one specific port That means traffic which goes in or out the monitored source ports will be duplicated into the mirror destination port Destination Po...

Page 68: ...looded Unicast Broadcast Multicast and Bbroadcast only types are only for ingress frames The egress rate only supports All type All the ports support port ingress and egress rate control For example assume port 1 is 10Mbps users can set it s effective egress rate is 1Mbps ingress rate is 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate Ingress Enter the por...

Page 69: ...59 Chapter3 Figure 3 29 Rate Limiting ...

Page 70: ...cally The industrial switch supports port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is Disable Figure 3 30 VLAN Configuration VLAN configuration Port based VLAN Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored In orde...

Page 71: ...own the select item menu of VLAN Operation Mode and select Port Based mode Click Add to add a new VLAN group The maximum VLAN group is up to 256 VLAN groups Entering the VLAN name group ID and grouping the members of VLAN group And then click Apply ...

Page 72: ...switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers You can create Tag based VLAN and enable or disable GVRP protocol There are 256 VLAN groups to provide configure Enable 802 1Q VLAN the all ports on the switch belong to default VLAN VID is 1 The default VLAN can t be deleting GVRP allows auto...

Page 73: ...the port that you want to configure Link Type there are 3 types of link type Access Link single switch only allow user to group ports by setting the same VID Trunk Link the extended application of Access Link While the ports are set in this type they can forward the packets with specified tag among the switches which are included in the same VLAN group Hybrid Link Both Access Link and Trunk Link a...

Page 74: ...EKI 7659CPI_Manual_ed33 64 Figure 3 34 802 1Q Group Configuration You can Change the VLAN group name and VLAN ID Click Apply Figure 3 35 802 1Q Group Configuration Edit ...

Page 75: ...s the highest priority and is selected as the root If the value changes user must reboot the switch The value must be multiple of 4096 according to the protocol standard rule Max Age 6 40 the number of seconds a bridge waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 the time that controls s...

Page 76: ...endent upon whether the port concerned can only be connected to exactly one other bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True is P2P enabling False is P2P disabling Edge The port directly connected to end stat...

Page 77: ...Strings You can define new community string set and remove unwanted community string String Fill the name string RO Read only Enables requests accompanied by this string to display MIB object information RW Read write Enables requests accompanied by this string to display MIB object information and to set MIB objects Click Add To remove the community string select the community string that you hav...

Page 78: ...p Version Select the SNMP trap version type v1 or v2c Click Add To remove the community string select the community string that you have defined and click Remove You cannot edit the name of the default community string set Figure 3 39 Trap Configuration interface SNMPV3 Configuration Configure the SNMP V3 function Context Table Configure SNMP v3 context table Assign the context name of context tab...

Page 79: ...o remove unwanted context name Figure 3 40 SNMP V3 configuration interface Group Table Configure SNMP v3 group table Security Name User ID Assign the user name that you have set up in user table Group Name Set up the group name ...

Page 80: ...el Context Match Rule Select the context match rule Read View Name Set up the read view Write View Name Set up the write view Notify View Name Set up the notify view Click Add to add context name Click Remove to remove unwanted context name MIBview Table Configure MIB view table ViewName Set up the name Sub Oid Tree Fill the Sub OID Type Select the type exclude or included Click Add to add context...

Page 81: ...n accordance with the 8 4 2 1 policy rule Use a strict priority scheme Always higher queue will be processed first except higher queue is empty Priority Type there are 5 priority type selections available Disable means no priority type is selected Port base the port priority will follow the Port base that you have assigned High middle low or lowest COS only the port priority will only follow the C...

Page 82: ..._Manual_ed33 72 Figure 3 41 QoS Configuration interface Port Base Priority Configure per port priority level Port 1 Port 10 each port has 4 priority levels High Middle Low and Lowest Click Apply COS Configuration ...

Page 83: ...uters to establish multicast group memberships It is an integral part of the IP multicast specification like ICMP for unicast connections IGMP can be used for online video and gaming and allows more efficient use of resources when supporting these uses IGMP have three fundamental types of message as follows Table 3 19 IGMP types Message Description Query A message sent from the querier IGMP router...

Page 84: ...ill be enabled by the X Ring configuration interface Also user can identify the switch as the ring master from the R M LED panel of the LED panel on the switch The system also supports the coupling ring that can connect 2 or more X Ring group for the redundant backup function and dual homing function that prevent connection lose between X Ring group and upper level core switch Enable X Ring To ena...

Page 85: ...ote When the X Ring function enable user must disable the RSTP The X Ring function and RSTP function cannot exist at the same time Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off ...

Page 86: ...P destination port for accounting requests to the specified Radius Server Shared Key set an encryption key for using during authentication sessions with the specified radius server This key must match the encryption key used on the Radius Server NAS Identifier set the identifier for the radius client Click Apply Figure 3 44 802 1x Radius System Configuration 802 1x Radius Port Configuration You ca...

Page 87: ...thentication session Supplicant Timeout set the period of time the switch waits for a supplicant response to an EAP request Server Timeout set the period of time the switch waits for a server response to an authentication request Max Requests set the number of authentication that must time out before authentication fails and the authentication session ends Reauth period set the period of time afte...

Page 88: ...y delete a static MAC address MAC Address Table Static MAC Address You can add static MAC address in the switch MAC table here MAC Address Enter the MAC address of the port that should permanently forward traffic regardless of the device network activity Port No pull down the selection menu to select the port number Click Add If you want to delete the MAC address from filtering table select the MA...

Page 89: ...ct the MAC address and click Delete MAC Address Table All MAC Addresses You can view the port of the connected device s MAC address and related devices MAC address Select the port The selected port of static MAC address information will be displayed here Click Clear MAC Table to clear the current port static MAC address information on screen Figure 3 49 All MAC Address interface ...

Page 90: ...f specification Capacitive Detection If the port and capacitive detection are enabled the capacitances state reads in the voltage result from the constant current This is then subtracted from the pre capacitance voltage to get a charge rate If this charge rate is within the window of the PD signatures the device is considered to be discovered Start Showing with a tick symbol the system initializes...

Page 91: ...ffect Factory Default Reset switch to default configuration Click Reset to reset all configurations to the default value Figure 3 51 Factory Default interface Save Configuration Save all configurations that you have made in the system To ensure the all configuration will be saved Click Save to save the all configuration to the flash memory Figure 3 52 Save Configuration interface System Reboot ...

Page 92: ...EKI 7659CPI_Manual_ed33 82 Figure 3 53 System Reboot interface Reboot the switch in software reset Click Reboot to reboot the system ...

Page 93: ...83 Troubleshooting CHAPTER ...

Page 94: ... of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying If the power indicator does not light up when the power cord is plugged in user may have a problem with power cord Then check f...

Page 95: ...85 Pin Assignment Wiring APPENDIX ...

Page 96: ...EKI 7659CPI_Manual_ed33 86 Appendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 3 EIA TIA 568A ...

Page 97: ...87 Figure A 4 DB 9 pin female connector DB9 Connector RJ 45 Connector NC 1 Orange White 2 2 Orange 3 3 Green White NC 4 Blue 5 5 Blue White NC 6 Green NC 7 Brown White NC 8 Brown ...

Page 98: ...EKI 7659CPI_Manual_ed33 88 ...

Page 99: ...89 Compatible SFP Modules APPENDIX ...

Page 100: ...m Brand Part Number Mode Transmission Distance 1 AVAGO AFBR 5710PZ Multi mode 550m 2 APAC LM28 C3S TC N 550m 3 HOATECH HTI8512 X5ATO 550m 4 SPACE SHUTTLE S56L S85 6L N 550m 5 LuminentOIC SP GB LX Single mode 10km SP GB ELX 20km SP GB XD 50km 6 AVAGO AFCT 5710PZ 10km 7 APAC LS38 C3M TC N 20km 8 SPACE SHUTTLE S56L L13 6L N 10km ...

Page 101: ...91 ...

Reviews: