1.1 Introduction 

 

The EKI-2725 is a full industrial Gigabit Ethernet switch. Featuring 5 x 
10/100/1000Base-TX ports, the EKI-2725 is designed not only to handle data intensive 
applications, but by also featuring the "Jumbo Frames" function with an MTU 
(Maximum Transmission Unit) up to 9Kbytes in one frame, the EKI-2725 can handle 
voice, video, and even large multimedia transmissions at Gigabit high speeds. 

 

1.1.1 High-Speed 

Transmissions 

The EKI-2725 includes a switch controller that can automatically sense transmission 
speeds (10/100/1000 Mbps). The RJ-45 interface can also be auto-detected, so MDI or 
MDI-X is automatically selected and a crossover cable is not required. All Ethernet 
ports have memory buffers that support the store-and-forward mechanism. This 
assures that data is properly transmitted. 

 
 

1.1.2 

Dual Power Input 

EKI-2725 redundant power input design is with power reserve protection to prevent the 
switch device broken by wrong power wiring. When one of power input is fail, P-Fail 
LED will turn on and send an alarm through a relay output for notifying user. 

 
 

1.1.3 Flexible 

Mounting 

EKI-2725 is compact (37 x 140 x 95 mm) and can be mounted on a DIN-rail or a panel, 
so it is suitable for any space-constrained environment. 

 
 

1.1.4 Advanced 

Protection 

EKI-2725 supports up to 3,000 VDC surge protection for power line, and also supports 
4000V ESD for Ethernet ports. With these 2 strong protections, it can secure 
equipment against unregulated voltage and make systems safer and more reliable. 
Further, EKI-2725 provides currency overload protection with a resettable fuse to 
ensure that the device component won’t be damaged by overload current. 

 
 

1.1.5 

Wide Operating Temperature 

The operating temperature of the EKI-2725 is between -40 ~ 75 

 (wide operating 

temperature model) or -10 ~ 60 

 (standard model). With such a wide range, you can 

use the EKI-2725 in some of the harshest industrial environments that exist. 

 
 

1.1.6 Easy 

Troubleshooting 

LED indicators make troubleshooting quick and easy. Each 10/100/1000 Base-TX port 
has 2 LEDs that display the link status, transmission speed and collision status. Also 
the three power indicators P1, P2 and P-Fail help you diagnose immediately. 

 
 
 

Summary of Contents for EKI-2725

Page 1: ...EKI 2725 5 port Industrial Unmanaged Gigabit Ethernet Switch User Manual...

Page 2: ...m or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibilit...

Page 3: ...lacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem enc...

Page 4: ...ate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential a...

Page 5: ...ything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transien...

Page 6: ...age 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power b...

Page 7: ...units mm 9 Figure 2 1 Front View of EKI 2725 9 Figure 2 2 Side View of EKI 2725 10 Figure 2 3 Rear View of EKI 2725 11 Figure 2 4 Top View of EKI 2725 12 2 3 Mounting 13 2 3 1 Wall mounting 13 Figure...

Page 8: ...EKI 2725 User Manual viii...

Page 9: ...1 Chapter1 Overview Sections include z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER...

Page 10: ...ower input is fail P Fail LED will turn on and send an alarm through a relay output for notifying user 1 1 3 Flexible Mounting EKI 2725 is compact 37 x 140 x 95 mm and can be mounted on a DIN rail or...

Page 11: ...egotiation Supports jumbo frame transmission up to 9Kbytes Provides surge EFT protection 3 000 VDC for power line Supports 4 000 VDC Ethernet ESD protection Provides Slim size DIN rail with IP30 metal...

Page 12: ...ve Duplex Collision Power Power Consumption Max 4 6W Power Input 2 x Unregulated 12 48 VDC Fault Output 1 Relay Output Mechanism Dimensions WxHxD 37 x 140 x 95 mm Enclosure IP30 Metal shell with solid...

Page 13: ...UL 60950 1 CAN CSA C22 2 No 60950 EMC U S A FCC Part 15 CISPR 22 EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 11 12 EN61000 6 2 Freefall IEC60068 2 32 Shock IEC6...

Page 14: ...ation CD ROM with software and User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 2725 Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precaution A...

Page 15: ...7 Chapter2 Installation Sections include z LED Indicators z Dimensions z Mounting z Network Connection z Power Connection CHAPTER...

Page 16: ...table Table 2 1 EKI 2725 LED Definition LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Po...

Page 17: ...9 Chapter2 2 2 Dimensions units mm Figure 2 1 Front View of EKI 2725...

Page 18: ...EKI 2725 User Manual 10 Figure 2 2 Side View of EKI 2725...

Page 19: ...11 Chapter2 Figure 2 3 Rear View of EKI 2725...

Page 20: ...EKI 2725 User Manual 12 The power relay terminal block is located on the top Please refer to page 16 for pin assignment Figure 2 4 Top View of EKI 2725...

Page 21: ...mounted by using the included mounting kit Then hang on the EKI 2725 to the nails on the wall First use the screws included in the package to combine the EKI 2725 and metal mounting kit And then you...

Page 22: ...eps The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang th...

Page 23: ...15 Chapter2 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2...

Page 24: ...I X to another hub or switch either MDI X or uplink MDI port The EKI 2725 supports auto crossover to make networking more easy and flexible You can connect any RJ 45 MDI X station port on the switch t...

Page 25: ...17 Chapter2 Troubleshooting CHAPTER...

Page 26: ...be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet 3 Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes commo...

Page 27: ...19 Chapter2 Pin Assignment Wiring APPENDIX...

Page 28: ...EKI 2725 User Manual 20 Appendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A...

Reviews: