EKI-1751-AE User Manual

v

Safety Instructions

Read these safety instructions carefully.

Keep this User Manual for later reference.

Disconnect this equipment from any DC outlet before cleaning. Use a damp 
cloth. Do not use liquid or spray detergents for cleaning.

For plug-in equipment, the power outlet socket must be located near the equip-
ment and must be easily accessible.

Keep this equipment away from humidity.

Put this equipment on a reliable surface during installation. Dropping it or letting 
it fall may cause damage.

The openings on the enclosure are for air convection. Protect the equipment 
from overheating. DO NOT COVER THE OPENINGS.

Make sure the voltage of the power source is correct before connecting the 
equipment to the power outlet.

Position the power cord so that people cannot step on it. Do not place anything 
over the power cord.

All cautions and warnings on the equipment should be noted.

If the equipment is not used for a long time, disconnect it from the power source 
to avoid damage by transient overvoltage.

Never pour any liquid into an opening. This may cause fire or electrical shock.

Never open the equipment. For safety reasons, the equipment should be 
opened only by qualified service personnel.

If one of the following situations arises, get the equipment checked by service 
personnel:

The power cord or plug is damaged.

Liquid has penetrated into the equipment.

The equipment has been exposed to moisture.

The equipment does not work well, or you cannot get it to work according to 
the user's manual.

The equipment has been dropped and damaged.

The equipment has obvious signs of breakage.

DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE 
STORAGE TEMPERATURE MAY GO -40°C (-40°F) ~ 75°C (165°F). THIS 
COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A 
CONTROLLED ENVIRONMENT.

The sound pressure level at the operator's position according to IEC 704-1:1982 
is no more than 70 dB (A).
DISCLAIMER: This set of instructions is given according to IEC 704-1. Advant-
ech disclaims all responsibility for the accuracy of any statements contained
herein.

Summary of Contents for EKI-1751-AE

Page 1: ...User Manual EKI 1751 AE Long Reach Ethernet Extender...

Page 2: ...llation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers...

Page 3: ...can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a res...

Page 4: ...immediately 1 x VDSL2 LAN Extender 1 x DIN Rail Mounting Bracket and Screws 1 x Wall mounting Bracket Warning Warnings indicate conditions which if not observed can cause personal injury Caution Cauti...

Page 5: ...sed for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment...

Page 6: ...eriod The following guidelines are also recommended Wear a grounded wrist or ankle strap and use gloves to prevent direct contact to the device before servicing the device Avoid nylon gloves or work c...

Page 7: ...3 Specifications 3 1 4 Applications 4 1 5 Deployment Option Point to Point 4 Chapter 2 Hardware Installation 5 2 1 Front Panel 6 2 2 Rear Panel 8 2 3 Installation 8 Chapter 3 Appendix 9 3 1 Connector...

Page 8: ...tender Application 4 Figure 1 2 Deployment Option Point to Point 4 Figure 2 1 Front Panel 6 Figure 2 2 DIP Swtiches 7 Figure 2 3 Rear Panel 8 Figure 2 4 Installation 8 Figure 3 1 Ethernet Port Connect...

Page 9: ...Chapter 1 1Introduction...

Page 10: ...your telephone line achieve its best performance than before EKI 1751 AE VDSL2 Ethernet Extender also supports selectable CPE and CO mode By selecting operation modes one with CO mode and the other w...

Page 11: ...lan SNR Margin CO CPE Ethernet IEEE 802 3 10 100 BaseT 802 3u 802 3x 802 1q VDSL2 ITU T G 993 2 VDSL2 Profiles 17a and 30a IP30 rating enclosure Input Voltage 12 VDC 1A Power Connector Barrel jack Sur...

Page 12: ...t CAT CAT 5e 5e Fast Ethernet Fast Ethernet Ethernet CAT 5e Fast Ethernet EKI 1751I Master Ethernet Network Ethernet Ethernet CAT CAT 5e 5e Fast Ethernet Fast Ethernet Ethernet CAT 5e Fast Ethernet EK...

Page 13: ...Chapter 2 2Hardware Installation...

Page 14: ...J 45 connector show the status below 2 The following table describes the LEDs function of the product LEDs for LAN Blinking On Off Activity Link UP Link UP 100Mbps 10Mbps Full Duplex Half Duplex LED C...

Page 15: ...on both downstream and upstream Asymmetric Provides highest line rate in short range in asymmetric mode Pin 4 General protection 9dB Better channel noise protection with SNR up to 9 dB 6dB Original ch...

Page 16: ...User Manual 2 2 Rear Panel Figure 2 3 Rear Panel The DC Jack on the rear panel can be connected to power supply adaptor with the DC input 2 3 Installation Please see the illustration below Figure 2 4...

Page 17: ...Chapter 3 3Appendix...

Page 18: ...The Ethernet Port interface is an 8 position Modular Jack The table below displays the pin out assignments Figure 3 1 Ethernet Port Connector RJ 45 Pin Number Description 1 RX Receive data 2 RX Receiv...

Page 19: ...interface is standard eight pin modular jack The table below displays the pin out assignments Figure 3 2 VDSL Interface Pin Assignments RJ 45 Pin Number Description 1 Not used 2 Not used 3 Not used 4...

Page 20: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Reviews: