background image

RF to Serial Extender

RSE500A

©  2010 UTAS Inc.

UTAS IS NOT RESPONSIBLE FOR TECHNICAL OR EDITING ERRORS IN THE CONTENTS OF THIS GUIDE.  UTAS IS NOT 

RESPONSIBLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER 

RESULTING FROM ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF DOCUMENTS, OR 

LOSS OF USE. 

THE CONTENTS AND INFORMATION INCLUDED IN THIS GUIDE ARE COPYRIGHT PROTECTED. 
THUS, THEY CANNOT BE COPIED, REPRODUCED, OR TRANSLATED WITHOUT UTAS INC’S WRITTEN CONSENT.  

UTAS

www.utas.co.kr

User Manual

Summary of Contents for RSE500A

Page 1: ...PECIAL INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF DOCUMENTS OR LOSS OF USE THE CONTENTS AND INFORMATION INCLUDED IN THIS GUIDE ARE COPYRIGHT PROTECTED THUS THEY CANNOT BE COPIED REPRODUCED OR TRANSLATED WITHOUT UTAS INC S WRITTEN CONSENT UTAS www utas co kr User Manual ...

Page 2: ...he target devices through the cables Features Various control method RS232 RS485 Addressable channels and IDs for multi zone 2 4GHz RF Zigbee Module 2 4GHz external antenna 2dB Specification Terminal Block Type Port Addressable 4 RS232 Ports 1 RS485 Port Radio Frequency 2 4GHz Built in Zigbee Module Coverage approximately 100m in case 2dB antenna Addressable 16 Extender IDs Addressable 16 Channels...

Page 3: ...duct Kit Details 2 Top View Bottom View Rear View Power LED Control LED RF Receiver antenna Basically 2dB Channel Switch ID Switch RS485 port RS232 port DC Adapter power connection 12V 1 5A www utas co kr ...

Page 4: ... is no more than 15m RS485 supports One on Multi communication composed of 485 and 485 The distance of communication by cable is more than 1Km There are many serial communication devices such as Matrix Switcher Projector Lighting control switch and other special devices to perform accurate works The RS232 and RS485 protocol command value of each device consists of Hex or Ascii code When inputting ...

Page 5: ... receivers RSE500A is supported with 4 ports No 1 to 4 You can connect to RS232 port using Terminal block Each port sends the signal individually so that you can control each device independently DC Power Port Connect power connection with DC12V adaptor Note Required to stay connected with power at any time RS232 Terminal block RS485 Terminal block Channel ID Rotary Switch UTP cable for communicat...

Page 6: ...n There are 8 lines in UTP cable You can use two line of the same color as a set Peel off the sheath of the UTP cable by 5mm and then connect to the terminal block 5mm Fasten the cable screwing clockwise using a flat head screwdriver RSE500A Terminal block D sub 9 pin connector for RS232 Sold separately RS232 port of each device is different in manufacturers and models D sub 9 pin connector is mos...

Page 7: ... If the touch panel UX3500 ITRC8500DX etc supported only one way communication then no need to connect to TX of device Pin number of TX RX Ground used to communicate is different in each manufacturer and models even D sub 9 pin port in the device being supported Check the pin number according to device s manual then connect it properly Connect RX of device to terminal block TX of RSE500A Connect T...

Page 8: ...ecause the divided ID can send protocol command separately you can control up to 8 switches at once by 1 RS485 port of RSE500A RS485 Cable Installation ID 1 ID 2 ID 3 ID 4 ID 5 ID 6 ID 7 ID 8 RS485 consists of 485 485 It is to connect the same electrode of RSE500A and RS485 of device The 5th port of RSE500A is exclusive port of RS485 Connect to each device by using provided terminal block of RS485...

Page 9: ...Installation Example www utas co kr 8 Projector Matrix Switcher Lighting Curtain ...